| Parameter | Value |
|---|---|
| UK Declaration of Conformity | |
| EAN | 4047621002705 |
| UPC | 804766058592 |
| ETIM | 5 |
| UNSPSC | 15 |
| eClass | 6 |
| Group Code | R711 |
| wire length | 3 m |
| Confirmation | |
| Metal Factor | None |
| Date5/11/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 3750 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85365080 |
| Product family | SIRIUS 3SE66, 3SE67 non-contact safety switches, magnet |
| last modified: | 10/6/2021 |
| Net Weight (kg) | 0,217 Kg |
| type of voltage | DC |
| fastening method | screw fixing |
| product function | |
| Country of origin | Germany |
| ● as NC contact | |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● safety-related | 0 |
| Packaging Dimension | 30,00 x 260,00 x 255,00 |
| Product Description | Magnet switch Switching element, rectangular small 26 x 36 mm, for door hinge Left, Contact elements: Safety contacts 2 NC Signaling contact 1 NC with 3 m connecting cable without LED, the matching solenoid 3SE6714-3CA solenoid 3SE6714-3CA or offset by 90° 3SE6724-3CA |
| product designation | Magnetically operated switch |
| protection class IP | IP67 |
| switching frequency | 5 Hz |
| width of the sensor | 26 mm |
| height of the sensor | 36 mm |
| length of the sensor | 13 mm |
| ● positive opening | No |
| design of the product | Rectangular sensor unit |
| Product Lifecycle (PLM) | PM300:Active Product |
| Voltage type (EF000187) | DC |
| Width sensor (EF007094) | 26.0 |
| General Product Approval | EMC |
| evaluation unit required | yes |
| material of cable sheath | PVC |
| product type designation | 3SE66 |
| Declaration of Conformity | other |
| material of the enclosure | Plastic, glass-fiber reinforced thermoplastic |
| Coating housing (EF001601) | - |
| Diameter sensor (EF007111) | - |
| Export Control Regulations | AL : N / ECCN : N |
| ● for signaling function | 0 |
| Height of sensor (EF007283) | 36.0 |
| Length of sensor (EF007334) | 13.0 |
| Material housing (EF001596) | Plastic |
| Standard lead time ex-works | 60 Day/Days |
| Surcharge for Raw Materials | None |
| operating power rated value | 10 W |
| Package size unit of measure | MM |
| Type of actuation (EF006949) | Magnet |
| Substance Prohibitance (Date) | 07/01/2006 |
| Switching distance (EF003647) | - |
| assured operating distance ON | 5 mm |
| opening direction of the door | left |
| operating voltage rated value | 75 V |
| type of electrical connection | cable |
| Ambient temperature (EF002386) | ['-25', '70'] |
| Min. output current (EF004045) | - |
| assured operating distance OFF | 15 mm |
| design of the actuating element | magnet |
| number of semiconductor outputs | |
| operational current rated value | 400 mA |
| design of the switching function | NC contact |
| proportion of dangerous failures | |
| With status indication (EF001602) | - |
| material of the active sensor area | Plastic, glass-fiber reinforced thermoplastic |
| Type of switching output (EF003962) | - |
| Construction type housing (EF004008) | - |
| Degree of protection (IP) (EF005474) | IP67 |
| ambient temperature during operation | -25 ... +70 °C |
| number of NC contacts safety-related | 2 |
| number of NO contacts safety-related | 0 |
| Article Number (Market Facing Number) | 3SE6617-3CA04 |
| Rated supply voltage at DC (EF007078) | ['-', 'DC'] |
| SIL according to IEC 61508 (EF009889) | 3 |
| Degree of protection (NEMA) (EF011959) | - |
| Type of electric connection (EF003961) | Cable |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Protected switch distance ON (EF004012) | 5.0 |
| reference code according to IEC 81346-2 | S |
| Protected switch distance OFF (EF004011) | 15.0 |
| Suitable for safety functions (EF001597) | true |
| type of voltage of the operating voltage | DC |
| — safety-related instantaneous contact | 2 |
| Category according to EN 954-1 (EF006782) | - |
| Rated supply voltage at AC 50 Hz (EF007076) | ['-', 'DC'] |
| Rated supply voltage at AC 60 Hz (EF007077) | ['-', 'DC'] |
| suitability for use safety-related circuits | Yes |
| ● control function for downstream devices | No |
| ● cross-circuit/short-circuit recognition | Yes |
| Explosion safety category for gas (EF003997) | None |
| mechanical installation condition for sensor | can be installed almost flush |
| number of NC contacts for auxiliary contacts | 3 |
| number of NO contacts for auxiliary contacts | 0 |
| shock resistance according to IEC 60068-2-27 | Sinusoidal half-wave 30g / 11 ms |
| Explosion safety category for dust (EF003998) | None |
| ● with low demand rate according to SN 31920 | 50 % |
| vibration resistance according to IEC 60068-2-6 | 10 ... 55 Hz: 1 mm |
| ● with high demand rate according to SN 31920 | 50 % |
| — for signaling function instantaneous contact | 1 |
| Max. output current at protected output (EF004035) | - |
| performance level (PL) according to EN ISO 13849-1 | e |
| Mechanical mounting condition for sensor (EF004041) | Quasi-flat |
| Safety Integrity Level (SIL) according to IEC 61508 | 3 |
| number of switching contacts for signaling function | 1 |
| Number of protected semiconductor outputs (EF003951) | 0 |
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K |
| B10 value with high demand rate according to SN 31920 | 12 500 000 |
| Type of interface for safety communication (EF003956) | - |
| ● as NO contact safety-related instantaneous contact | 0 |
| Cross-/short circuit identification possible (EF004093) | true |
| number of outputs as contact-affected switching element | |
| Number of protected contact energized outputs (EF003952) | 0 |
| Performance level according to EN ISO 13849-1 (EF007399) | Level e |
| With monitoring function downstream switching devices (EF004052) | false |
| Number of semiconductor outputs with signalling function (EF003945) | 0 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| Number of contact energized outputs with signalling function (EF003946) | 1 |
| T1 value for proof test interval or service life according to IEC 61508 | 20 y |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| General Product ApprovalEMCFunctional Safety/Safety of MachineryConfirmationMiscellaneousDeclaration of ConformityotherUK Declaration of ConformityConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide