| Parameter | Value |
|---|---|
| EAN | 4011209866713 |
| UPC | 040892619829 |
| ETIM | 5 |
| IDEA | 4 |
| UNSPSC | 14 |
| eClass | 6 |
| ● solid | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) |
| Group Code | R711 |
| Date5/9/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LA------ |
| Product Group | 5317 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85365080 |
| Product family | Enclosure width 40 mm acc. to EN 50041 |
| last modified: | 3/23/2022 |
| Net Weight (kg) | 0,090 Kg |
| repeat accuracy | 0.05 mm |
| thermal current | 10 A |
| active principle | mechanical |
| cable entry type | 1x (M20 x 1.5) |
| fastening method | screw fixing |
| shock resistance | |
| Country of origin | Germany |
| circuit principle | slow-action contacts |
| mounting position | any |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● during storage | -40 ... +90 °C |
| Packaging Dimension | 45,00 x 42,00 x 97,00 |
| Product Description | Basic switch with increased corrosion protection for position switch 3SE513 Enclosure plastic according to EN 50041 Device connection 1x (M20 x 1.5) 1 NO/1 NC slow-action contacts without actuator head |
| ambient temperature | |
| degree of pollution | class 3 |
| product designation | Mechanical safety switches |
| protection class IP | IP66/IP67 |
| width of the sensor | 40 mm |
| length of the sensor | 85.7 mm |
| ● during operation | -25 ... +85 °C |
| design of the housing | block, narrow |
| Product Lifecycle (PLM) | PM300:Active Product |
| Width sensor (EF007094) | 40.0 |
| design of the interface | without |
| ● at 24 V rated value | 6 A |
| ● at AWG cables solid | 1x (20 ... 16), 2x (20 ... 18) |
| coating of the enclosure | Other types |
| product type designation | 3SE5 |
| ● at 125 V rated value | 6 A |
| ● at 240 V rated value | 6 A |
| ● at 250 V rated value | 0.27 A |
| ● at 400 V rated value | 4 A |
| Forced opening (EF006694) | true |
| material of the enclosure | plastic |
| Coating housing (EF001601) | Other |
| Diameter sensor (EF007111) | - |
| Export Control Regulations | AL : N / ECCN : N |
| ● at AWG cables stranded | 1x (20 ... 16), 2x (20 ... 18) |
| Height of sensor (EF007283) | 37.3 |
| Length of sensor (EF007334) | 85.7 |
| Material housing (EF001596) | Plastic |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| Output electronic (EF006987) | FALSE |
| Package size unit of measure | MM |
| Type Examination Certificate | UK Declaration of Conformity |
| Type of interface (EF006977) | None |
| operational current at AC-15 | |
| operational current at DC-13 | |
| Substance Prohibitance (Date) | 07/01/2006 |
| Switching function (EF000189) | Slow-action switch |
| manufacturer's article number | |
| type of electrical connection | screw-type terminals |
| insulation voltage rated value | 400 V |
| design of the actuating element | Other, without, cover |
| design of the switching contact | mechanical |
| operating frequency rated value | 50 ... 60 Hz |
| ● according to IEC 60068-2-27 | 30g / 11 ms |
| design of the switching function | Positive opening with appropriate positive opening actuator head |
| With status indication (EF001602) | false |
| product function positive opening | Yes |
| suitability for use safety switch | Yes |
| Type of control element (EF006976) | None |
| Construction type housing (EF004008) | Cuboid |
| Degree of protection (IP) (EF005474) | IP66/IP67 |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3SE5132-0BA00-1CA0 |
| Functional Safety/Safety of Machinery | Declaration of Conformity |
| Degree of protection (NEMA) (EF011959) | - |
| Switching function latching (EF007447) | false |
| Type of electric connection (EF003961) | Cable entry metrical |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| explosion protection category for dust | none |
| ● of the supplied switching contacts | 3SE5000-0BA00 |
| reference code according to IEC 81346-2 | B |
| Suitable for safety functions (EF001597) | true |
| Alignment of the control element (EF008793) | Roller cam straight |
| design of the housing according to standard | Yes |
| number of switching contacts safety-related | 1 |
| Explosion safety category for gas (EF003997) | None |
| number of NC contacts for auxiliary contacts | 1 |
| number of NO contacts for auxiliary contacts | 1 |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²) |
| Explosion safety category for dust (EF003998) | None |
| continuous current of the DIAZED fuse link gG | 6 A |
| Number of safety auxiliary contacts (EF006940) | 1 |
| continuous current of the C characteristic MCB | 1 A; for a short-circuit current smaller than 400 A |
| ● of the supplied empty enclosure with cover | 3SE5132-0AA00-1CA, on request |
| Ambient temperature during operating (EF007515) | ['-25', '85'] |
| vibration resistance according to IEC 60068-2-6 | 0.35 mm/5g |
| continuous current of the quick DIAZED fuse link | 10 A; for a short-circuit current smaller than 400 A |
| mechanical service life (switching cycles) typical | 15 000 000 |
| minimum actuating force in directions of actuation | 20 N |
| Number of contacts as change-over contact (EF008257) | 1 |
| Rated operation current Ie at AC-15, 24 V (EF007084) | 6 |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 3 |
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K |
| Rated operation current Ie at AC-15, 125 V (EF007082) | 6 |
| Rated operation current Ie at AC-15, 230 V (EF001385) | - |
| Rated operation current Ie at DC-13, 125 V (EF007085) | 0.55 |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - |
| Type of interface for safety communication (EF003956) | None |
| Number of contacts as normally open contact (EF008256) | 1 |
| Number of contacts as normally closed contact (EF008255) | 1 |
| design of the interface for safety-related communication | without |
| electrical endurance (switching cycles) at AC-15 at 230 V typical | 100 000 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Imidazolidine-2-thio... CAS-No. 96-45-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Imidazolidine-2-thione (2-imidazoline-2-thiol)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Electrical operating cycles in one hour with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 | 6 000 |
| electrical endurance (switching cycles) with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 typical | 10 000 000 |
| General Product ApprovalConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityotherType Examination CertificateUK Declaration of ConformityConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide