


| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209536777 |
| UPC | 754554849812 |
| ETIM | 5 |
| IDEA | 4 |
| UNSPSC | 14 |
| eClass | 6 |
| ● solid | 2x (0.75 ... 2.5 mm²) |
| Group Code | R711 |
| Date5/2/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | LC------ |
| Product Group | 3750 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85365080 |
| Product family | Enclosure width 52 mm |
| last modified: | 1/26/2022 |
| Net Weight (kg) | 0,131 Kg |
| thermal current | 10 A |
| active principle | mechanical |
| cable entry type | 3x (M20 x 1.5) |
| fastening method | screw fixing |
| Country of origin | Germany |
| Marine / Shipping | other |
| circuit principle | slow-action contacts |
| mounting position | any |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● during storage | -30 ... +80 °C |
| Packaging Dimension | 67,00 x 107,00 x 45,00 |
| Product Description | Safety position switch with separate actuator Molded-plastic-encapsulated short enclosure, 3x(M20x1.5) lateral and face-end operation slow-action contact 1 NC, Pull-out force 5 N Supplied without actuator |
| ambient temperature | |
| product designation | safety position switch |
| protection class IP | IP67 |
| width of the sensor | 52 mm |
| length of the sensor | 75 mm |
| ● during operation | -30 ... +80 °C |
| design of the housing | wide |
| Product Lifecycle (PLM) | PM300:Active Product |
| Width sensor (EF007094) | 52.0 |
| design of the interface | without |
| ● at 24 V rated value | 4 A |
| coating of the enclosure | Other types |
| product type designation | 3SE22 |
| ● at 230 V rated value | 4 A |
| Declaration of Conformity | Test Certificates |
| Forced opening (EF006694) | - |
| material of the enclosure | glass fiber reinforced thermoplast |
| Coating housing (EF001601) | Other |
| Export Control Regulations | AL : N / ECCN : N |
| Height of sensor (EF007283) | 36.0 |
| Length of sensor (EF007334) | 75.0 |
| Material housing (EF001596) | Plastic |
| Standard lead time ex-works | 15 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| Type of interface (EF006977) | None |
| UK Declaration of Conformity | |
| operational current at AC-15 | |
| operational current at DC-13 | |
| Substance Prohibitance (Date) | 07/01/2006 |
| type of electrical connection | screw-type terminals |
| insulation voltage rated value | 500 V |
| design of the actuating element | without |
| design of the switching contact | mechanical |
| operating frequency rated value | 60 ... 50 Hz |
| design of the switching function | positive opening |
| With status indication (EF001602) | false |
| suitability for use safety switch | Yes |
| Construction type housing (EF004008) | Other |
| Degree of protection (IP) (EF005474) | IP67 |
| Type of switching contact (EF003591) | Slow-action switch |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3SE2257-6XX40 |
| Degree of protection (NEMA) (EF011959) | - |
| Type of electric connection (EF003961) | Cable entry metrical |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| explosion protection category for dust | none |
| reference code according to IEC 81346-2 | B |
| Suitable for safety functions (EF001597) | true |
| design of the housing according to standard | No |
| number of switching contacts safety-related | 1 |
| Explosion safety category for gas (EF003997) | None |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 1 |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 2x (0.75 ... 2.5 mm²) |
| Explosion safety category for dust (EF003998) | None |
| Number of safety auxiliary contacts (EF006940) | 1 |
| Ambient temperature during operating (EF007515) | ['-30', '80'] |
| mechanical service life (switching cycles) typical | 1 000 000 |
| Number of contacts as change-over contact (EF008257) | 0 |
| Rated operation current Ie at AC-15, 24 V (EF007084) | - |
| Rated operation current Ie at DC-13, 24 V (EF007087) | 4 |
| Region Specific PriceGroup / Headquarter Price Group | 41K / 41K |
| Rated operation current Ie at AC-15, 125 V (EF007082) | - |
| Rated operation current Ie at AC-15, 230 V (EF001385) | 4 |
| Rated operation current Ie at DC-13, 125 V (EF007085) | - |
| Rated operation current Ie at DC-13, 230 V (EF001386) | - |
| Type of interface for safety communication (EF003956) | None |
| Number of contacts as normally open contact (EF008256) | 1 |
| Number of contacts as normally closed contact (EF008255) | 0 |
| design of the interface for safety-related communication | without |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| General Product ApprovalConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityMiscellaneousMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide