Service time: Monday to Friday 9:00-18:00
3RW5517-3HA14 - 3RW5517-3HA14 SIEMENS SIRIUS soft starter 200-480 V 38 A, 110-250 V AC spring-type terminals
In Stock Hot Product

3RW5517-3HA14

3RW5517-3HA14 SIEMENS SIRIUS soft starter 200-480 V 38 A, 110-250 V AC spring-type terminals

$0.00USD
4465 in stock
Key Specifications
:Value
EAN:4047621039565
UPC:804766813955
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4047621039565
UPC804766813955
ETIM5
IDEA4
depth152 mm
width170 mm
UNSPSC15
eClass6
height275 mm
— solid2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Group CodeR711
trip classCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Price Group42S
Wire length
● upwards100 mm
Metal FactorLAO-----
● PROFIBUSYes
● forwards10 mm
Product Group4982
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
mounting typescrew fixing
● backwards0 mm
● downwards75 mm
Commodity Code85371098
Product family3RW55 soft starters
Service factor1.15
last modified:08/15/2020
● CE markingYes
● Modbus RTUYes
● Modbus TCPYes
Net Weight (kg)3,259 Kg
● EtherNet/IPYes
● UL approvalYes
● at the side5 mm
● of the fuse
● rated value480 V
Minimum load [%]10 %; Relative to set Ie
Start torque [%]10 ... 100 %
Torque limit [%]20 ... 200 %
product categoryHybrid switching devices
shock resistance15 g / 11 ms, from 6 g / 11 ms with potential contact lifting
● CSA-approvalYes
Country of originCzech Republic
Marine / Shippingother
Product component
mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
Function (EF000030)Single direction
Packaging Dimension285,00 x 376,00 x 282,00
Product DescriptionSIRIUS soft starter 200-480 V 38 A, 110-250 V AC spring-type terminals
Stopping torque [%]10 ... 100 %
ambient temperature
degree of pollution3, acc. to IEC 60947-4-2
product designationSoft starter
protection class IPIP00
Idle time adjustable0 ... 255 s
Starting voltage [%]20 ... 100 %
Stopping voltage [%]50 ... 50 %
vibration resistance15 mm up to 6 Hz; 2 g up to 500 Hz
● HMI-High FeatureYes
● during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
● PROFINET standardYes
Environmental category
digital output version3 normally-open contacts (NO) / 1 changeover contact (CO)
● of circuit breaker
Product Lifecycle (PLM)PM300:Active Product
With display (EF000458)true
● for control circuit100 ms
EMC emitted interferenceacc. to IEC 60947-4-2: Class A, Class B on request
General Product ApprovalEMC
Number of parameter sets3
Release class (EF006668)Adjustable
number of analog outputs1
product type designation3RW55
weight without packaging2.6 kg
Breakaway time adjustable0 ... 2 s
Torque control (EF009215)true
● PROFINET high-featureYes
● at 40 °C rated value65.8 A
● at 50 °C rated value58 A
● at 60 °C rated value52.8 A
Export Control RegulationsAL : N / ECCN : N
Internal bypass (EF009214)true
Power loss [W] at AC at AC
certificate of suitability
Impulse voltage rated value6 kV
Number of controlled phases3
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
Tightening torque [lbf·in]
● at 40 °C after Startup11 W
● at 50 °C after Startup10 W
● at 60 °C after Startup9 W
Package size unit of measureMM
Type of the motor protectionElectronic, tripping in the event of thermal overload of the motor
● at 40 °C during startup616 W
● at 50 °C during startup511 W
● at 60 °C during startup447 W
● for main current circuit100 ms
● number of digital inputs4
Electromagnetic compatibilityacc. to IEC 60947-4-2
Manufacturer's article number
Stopping time of soft starter0 ... 360 s
● for control circuit solid2x (0.25 ... 1.5 mm²)
● number of digital outputs4
For use in hazardous locationsDeclaration of Conformity
Product Dimensions (W x L x H)Not available
● Product function Auto-resetYes
● Product function DC brakingYes
● Product function event listYes
Breakaway voltage [%] adjustable40 ... 100 %
Control supply voltage frequency50 ... 60 Hz
● Product function PROFIenergyYes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules
● at DC-13 at 24 V rated value1 A
● during storage and transport-40 ... +80 °C
Communication module is supported
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
● Product function Manual RESETYes
● Product function remote resetYes
● Product function voltage rampYes
● at AC-15 at 250 V rated value3 A
● is supported HMI-High FeatureYes
● operating voltage rated value200 ... 480 V
Start-up ramp time of soft starter0 ... 360 s
● Product function analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
● Product function error logbookYes
● Product function motor heatingYes
● at 230 V at 40 °C rated value11 kW
● at 400 V at 40 °C rated value18.5 kW
Accuracy class acc. to IEC 61557-125 %
● Product function pump ramp downYes
● Product function screw terminalNo
● Product function torque controlYes
● Product function trace functionYes
● certificate of suitability ATEXYes
Current unbalance limiting value [%]10 ... 60 %
Degree of protection (IP) (EF005474)IP00
Usage category acc. to IEC 60947-4-2AC 53a
design of the overvoltage protectionVaristor
surge voltage resistance rated value6 kV
● Product function breakaway pulseYes
● certificate of suitability IECExYes
● during storage acc. to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● of HMI-Modul high-feature usable3RW5980-0HF00
● product function firmware updateYes
Article Number (Market Facing Number)3RW5517-3HA14
Current limiting value [%] adjustable125 ... 800 %
Rated operating voltage Ue (EF002418)['200', '480']
Voltage type for actuating (EF008242)AC
reference code acc. to DIN EN 81346-2Q
● Product function combined brakingYes
● of the gG fuse usable up to 690 V3NA3824-6; Type of coordination 1, Iq = 65 kA
Degree of protection (NEMA) (EF011959)-
Operating power for three-phase motors
WEEE (2012/19/EU) Take-Back ObligationYes
● at 200/208 V at 50 °C rated value10 hp
● at 220/230 V at 50 °C rated value10 hp
● at 460/480 V at 50 °C rated value20 hp
● between main and auxiliary circuit480 V; does not apply for thermistor connection
● during operation acc. to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during transport acc. to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● of circuit breaker usable at 400 V3RV2032-4WA10; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V3RV2032-4WA10; Type of coordination 1, Iq = 10 kA, CLASS 10
● at the digital inputs at DC maximum1 000 m
● of communication module Ethernet/IP3RW5980-0CE00
● Product function application wizardsYes
● Product function reversing operationYes
Blocking voltage of the thyristor maximum1 600 V
Operating current at inside-delta circuit
● Control supply voltage at AC at 50 Hz110 ... 250 V
● Control supply voltage at AC at 60 Hz110 ... 250 V
● Product function alternative run-downYes
● Product function condition monitoringYes
● Product function inside-delta circuitYes
● Product function spring-type terminalYes
Ground-fault monitoring limiting value [%]10 ... 95 %
Number of inputs for thermistor connection1; Type A PTC or Klixon / Thermoclick
● Product function ramp-down (soft stop)Yes
● between soft starter and motor maximum800 m
Operating power [hp] for three-phase motors
required spacing with side-by-side mounting
● Product function slave pointer functionYes
● of communication module PROFIBUS usable3RW5980-0CP00
● operating current at 40 °C rated value38 A
● operating current at 50 °C rated value33.5 A
● operating current at 60 °C rated value30.5 A
● product function communication functionYes
Buffering time in the event of power failure
Recovery time after overload trip adjustable60 ... 1 800 s
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)
● Number of digital inputs parameterizable4
● Product function ramp-up (soft starting)Yes
type of voltage of the control supply voltageAC
● Number of digital outputs parameterizable3
● Product function emergency operation modeYes
● of communication module Modbus RTU usable3RW5980-0CR00
● of communication module Modbus TCP usable3RW5980-0CT00
maximum permissible voltage for safe isolation
● Product function via software configurableYes
● product function motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Integrated motor overload protection (EF007297)Electronic, tripping in the event of thermal overload of the
Switching capacity current of the relay outputs
● Product function automatic parameterisationYes
● at AWG conductors for control circuit solid2x (24 ... 16)
● for main contacts with screw-type terminals18 ... 22 lbf·in
Product feature integrated bypass contact systemYes
Rated control supply voltage Us at DC (EF003980)['-', '-']
● product function intrinsic device protectionYes
● Number of digital outputs not parameterizable1
● Product function via software parameterizableYes
Control supply current in standby mode rated value100 mA
Rated operation current Ie at 40 °C Tu (EF007039)38
● Product function adjustable current limitationYes
Power loss [W] for rated value of the current at AC
● Operating current at 40 °C rated value minimum7.5 A
Relative negative tolerance of the operating voltage-15 %
Relative positive tolerance of the operating voltage10 %
Starting current at close of by-pass contact maximum0.2 A
contact rating of auxiliary contacts according to ULR300-B300
● of communication module PROFINET standard usable3RW5980-0CS00
Rated control supply voltage Us at AC 50HZ (EF003978)['110', '250']
Rated control supply voltage Us at AC 60HZ (EF003979)['110', '250']
● Product function operating measured value displayYes
● Type of electrical connection for control circuitspring-loaded terminals
Design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Relative negative tolerance of the operating frequency-10 %
Relative positive tolerance of the operating frequency10 %
installation altitude at height above sea level maximum5 000 m; Derating as of 1000 m, see catalog
— usable for High Faults at 460/480 V according to ULSiemens type: 3RV2742, max.40 A or 3VA51, max. 60 A; Iq max = 65 kA
● Product function programmable control inputs/outputsYes
● of communication module PROFINET high-feature usable3RW5950-0CH00
Holding current in the by-pass mode operating rated value165 mA
Rated surrounding temperature without derating (EF007074)40 °C
type of protection according to ATEX directive 2014/34/EUII (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb],II (2)D [Ex tb Db] [Ex pxb Db],I (M2) [Ex db Mb]
● Operating voltage at inside-delta circuit rated value200 ... 480 V
Rated power three-phase motor, inline, at 230 V (EF007053)11.0
Rated power three-phase motor, inline, at 400 V (EF007054)18.5
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 150 A; Iq = 100 kA
● at 230 V at inside-delta circuit at 40 °C rated value18.5 kW
● at 400 V at inside-delta circuit at 40 °C rated value30 kW
● type of electrical connection for main current circuitscrew-type terminals
Hardware fault tolerance acc. to IEC 61508 relating to ATEX0
— usable for Standard Faults at 460/480 V according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA
— usable for Standard Faults at 575/600 V according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA
● Product function removable terminal for control circuitYes
PFHD with high demand rate acc. to EN 62061 relating to ATEX0.0000005 1/h
● of the gG fuse usable at inside-delta circuit up to 500 V3NA3824-6; Type of coordination 1, Iq = 65 kA
PFDavg with low demand rate acc. to IEC 61508 relating to ATEX0.008
— usable for Standard Faults up to 575/600 V according to ULType: Class RK5 / K5, max. 150 A; Iq = 5 kA
● Product function Evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
● at 200/208 V at inside-delta circuit at 50 °C rated value15 hp
● at 220/230 V at inside-delta circuit at 50 °C rated value20 hp
● at 460/480 V at inside-delta circuit at 50 °C rated value40 hp
● of circuit breaker usable at 400 V at inside-delta circuit3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V at inside-delta circuit3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10
Safety Integrity Level (SIL) acc. to IEC 61508 relating to ATEXSIL1
● Product function creep speed in both directions of rotationYes
● Product function soft starting at heavy starting conditionsYes
Inrush current peak at connect of control supply voltage maximum43 A
Rated power three-phase motor, inside delta, at 230 V (EF007055)18.5
Rated power three-phase motor, inside delta, at 400 V (EF007056)30.0
● for auxiliary and control contacts with screw-type terminals7 ... 10.3 lbf·in
● for control circuit finely stranded with core end processing2x (0.25 ... 1.5 mm²)
● tightening torque for main contacts with screw-type terminals2 ... 2.5 N·m
● type of connectable conductor cross-sections for main contacts
Relative negative tolerance of the control supply voltage frequency-10 %
Relative positive tolerance of the control supply voltage frequency10 %
Duration of inrush current peak at connect of control supply voltage1.6 ms
● certificate of suitability according to ATEX directive 2014/34/EUBVS 18 ATEX F 003 X
Compliance with the substance restrictions according to RoHS directiveSince: 15.02.2018
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Relative negative tolerance of the control supply voltage at AC at 50 Hz-15 %
Relative negative tolerance of the control supply voltage at AC at 60 Hz-15 %
Relative positive tolerance of the control supply voltage at AC at 50 Hz10 %
Relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
● of back-up R fuse link for semiconductor protection usable up to 690 V3NE8024-1; Type of coordination 2, Iq = 65 kA
Relative negative tolerance of the operating voltage at inside-delta circuit-15 %
Relative positive tolerance of the operating voltage at inside-delta circuit10 %
● of full range R fuse link for semiconductor protection usable up to 690 V3NE1820-0; Type of coordination 2, Iq = 65 kA
— usable for High Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 60 A; Iq max = 65 kA
— usable for High Faults at 575/600 V at inside-delta circuit according to ULSiemens type: 3VA51, max. 60 A; Iq max = 65 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 150 A; Iq = 100 kA
● Tightening torque for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
● at AWG conductors for control circuit finely stranded with core end processing2x (24 ... 16)
T1 value for proof test interval or service life acc. to IEC 61508 relating to ATEX3 y
— usable for Standard Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA
— usable for Standard Faults at 575/600 V at inside-delta circuit according to ULSiemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, max. 150 A; Iq = 5 kA
● Type of connectable conductor cross-sections at AWG conductors for main current circuit solid2x (16 ... 12), 2x (14 ... 8)
General Product ApprovalEMCFor use in hazardous locationsFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / ShippingType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

SIRIUS soft starter 200-480 V 38 A, 110-250 V AC Spring connection. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top