| Parameter | Value |
|---|---|
| Value | |
| EAN | 4047621039565 |
| UPC | 804766813955 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 152 mm |
| width | 170 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 275 mm |
| — solid | 2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²) |
| Group Code | R711 |
| trip class | CLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2 |
| Price Group | 42S |
| Wire length | |
| ● upwards | 100 mm |
| Metal Factor | LAO----- |
| ● PROFIBUS | Yes |
| ● forwards | 10 mm |
| Product Group | 4982 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| mounting type | screw fixing |
| ● backwards | 0 mm |
| ● downwards | 75 mm |
| Commodity Code | 85371098 |
| Product family | 3RW55 soft starters |
| Service factor | 1.15 |
| last modified: | 08/15/2020 |
| ● CE marking | Yes |
| ● Modbus RTU | Yes |
| ● Modbus TCP | Yes |
| Net Weight (kg) | 3,259 Kg |
| ● EtherNet/IP | Yes |
| ● UL approval | Yes |
| ● at the side | 5 mm |
| ● of the fuse | |
| ● rated value | 480 V |
| Minimum load [%] | 10 %; Relative to set Ie |
| Start torque [%] | 10 ... 100 % |
| Torque limit [%] | 20 ... 200 % |
| product category | Hybrid switching devices |
| shock resistance | 15 g / 11 ms, from 6 g / 11 ms with potential contact lifting |
| ● CSA-approval | Yes |
| Country of origin | Czech Republic |
| Marine / Shipping | other |
| Product component | |
| mounting position | Vertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°) |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| insulation voltage | |
| product brand name | SIRIUS |
| Function (EF000030) | Single direction |
| Packaging Dimension | 285,00 x 376,00 x 282,00 |
| Product Description | SIRIUS soft starter 200-480 V 38 A, 110-250 V AC spring-type terminals |
| Stopping torque [%] | 10 ... 100 % |
| ambient temperature | |
| degree of pollution | 3, acc. to IEC 60947-4-2 |
| product designation | Soft starter |
| protection class IP | IP00 |
| Idle time adjustable | 0 ... 255 s |
| Starting voltage [%] | 20 ... 100 % |
| Stopping voltage [%] | 50 ... 50 % |
| vibration resistance | 15 mm up to 6 Hz; 2 g up to 500 Hz |
| ● HMI-High Feature | Yes |
| ● during operation | -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above |
| ● PROFINET standard | Yes |
| Environmental category | |
| digital output version | 3 normally-open contacts (NO) / 1 changeover contact (CO) |
| ● of circuit breaker | |
| Product Lifecycle (PLM) | PM300:Active Product |
| With display (EF000458) | true |
| ● for control circuit | 100 ms |
| EMC emitted interference | acc. to IEC 60947-4-2: Class A, Class B on request |
| General Product Approval | EMC |
| Number of parameter sets | 3 |
| Release class (EF006668) | Adjustable |
| number of analog outputs | 1 |
| product type designation | 3RW55 |
| weight without packaging | 2.6 kg |
| Breakaway time adjustable | 0 ... 2 s |
| Torque control (EF009215) | true |
| ● PROFINET high-feature | Yes |
| ● at 40 °C rated value | 65.8 A |
| ● at 50 °C rated value | 58 A |
| ● at 60 °C rated value | 52.8 A |
| Export Control Regulations | AL : N / ECCN : N |
| Internal bypass (EF009214) | true |
| Power loss [W] at AC at AC | |
| certificate of suitability | |
| Impulse voltage rated value | 6 kV |
| Number of controlled phases | 3 |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| Tightening torque [lbf·in] | |
| ● at 40 °C after Startup | 11 W |
| ● at 50 °C after Startup | 10 W |
| ● at 60 °C after Startup | 9 W |
| Package size unit of measure | MM |
| Type of the motor protection | Electronic, tripping in the event of thermal overload of the motor |
| ● at 40 °C during startup | 616 W |
| ● at 50 °C during startup | 511 W |
| ● at 60 °C during startup | 447 W |
| ● for main current circuit | 100 ms |
| ● number of digital inputs | 4 |
| Electromagnetic compatibility | acc. to IEC 60947-4-2 |
| Manufacturer's article number | |
| Stopping time of soft starter | 0 ... 360 s |
| ● for control circuit solid | 2x (0.25 ... 1.5 mm²) |
| ● number of digital outputs | 4 |
| For use in hazardous locations | Declaration of Conformity |
| Product Dimensions (W x L x H) | Not available |
| ● Product function Auto-reset | Yes |
| ● Product function DC braking | Yes |
| ● Product function event list | Yes |
| Breakaway voltage [%] adjustable | 40 ... 100 % |
| Control supply voltage frequency | 50 ... 60 Hz |
| ● Product function PROFIenergy | Yes; in connection with the PROFINET Standard and PROFINET High-Feature communication modules |
| ● at DC-13 at 24 V rated value | 1 A |
| ● during storage and transport | -40 ... +80 °C |
| Communication module is supported | |
| Operating frequency 1 rated value | 50 Hz |
| Operating frequency 2 rated value | 60 Hz |
| ● Product function Manual RESET | Yes |
| ● Product function remote reset | Yes |
| ● Product function voltage ramp | Yes |
| ● at AC-15 at 250 V rated value | 3 A |
| ● is supported HMI-High Feature | Yes |
| ● operating voltage rated value | 200 ... 480 V |
| Start-up ramp time of soft starter | 0 ... 360 s |
| ● Product function analog output | Yes; 4 ... 20 mA (default) / 0 ... 10 V |
| ● Product function error logbook | Yes |
| ● Product function motor heating | Yes |
| ● at 230 V at 40 °C rated value | 11 kW |
| ● at 400 V at 40 °C rated value | 18.5 kW |
| Accuracy class acc. to IEC 61557-12 | 5 % |
| ● Product function pump ramp down | Yes |
| ● Product function screw terminal | No |
| ● Product function torque control | Yes |
| ● Product function trace function | Yes |
| ● certificate of suitability ATEX | Yes |
| Current unbalance limiting value [%] | 10 ... 60 % |
| Degree of protection (IP) (EF005474) | IP00 |
| Usage category acc. to IEC 60947-4-2 | AC 53a |
| design of the overvoltage protection | Varistor |
| surge voltage resistance rated value | 6 kV |
| ● Product function breakaway pulse | Yes |
| ● certificate of suitability IECEx | Yes |
| ● during storage acc. to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
| ● of HMI-Modul high-feature usable | 3RW5980-0HF00 |
| ● product function firmware update | Yes |
| Article Number (Market Facing Number) | 3RW5517-3HA14 |
| Current limiting value [%] adjustable | 125 ... 800 % |
| Rated operating voltage Ue (EF002418) | ['200', '480'] |
| Voltage type for actuating (EF008242) | AC |
| reference code acc. to DIN EN 81346-2 | Q |
| ● Product function combined braking | Yes |
| ● of the gG fuse usable up to 690 V | 3NA3824-6; Type of coordination 1, Iq = 65 kA |
| Degree of protection (NEMA) (EF011959) | - |
| Operating power for three-phase motors | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● at 200/208 V at 50 °C rated value | 10 hp |
| ● at 220/230 V at 50 °C rated value | 10 hp |
| ● at 460/480 V at 50 °C rated value | 20 hp |
| ● between main and auxiliary circuit | 480 V; does not apply for thermistor connection |
| ● during operation acc. to IEC 60721 | 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
| ● during transport acc. to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
| ● of circuit breaker usable at 400 V | 3RV2032-4WA10; Type of coordination 1, Iq = 65 kA, CLASS 10 |
| ● of circuit breaker usable at 500 V | 3RV2032-4WA10; Type of coordination 1, Iq = 10 kA, CLASS 10 |
| ● at the digital inputs at DC maximum | 1 000 m |
| ● of communication module Ethernet/IP | 3RW5980-0CE00 |
| ● Product function application wizards | Yes |
| ● Product function reversing operation | Yes |
| Blocking voltage of the thyristor maximum | 1 600 V |
| Operating current at inside-delta circuit | |
| ● Control supply voltage at AC at 50 Hz | 110 ... 250 V |
| ● Control supply voltage at AC at 60 Hz | 110 ... 250 V |
| ● Product function alternative run-down | Yes |
| ● Product function condition monitoring | Yes |
| ● Product function inside-delta circuit | Yes |
| ● Product function spring-type terminal | Yes |
| Ground-fault monitoring limiting value [%] | 10 ... 95 % |
| Number of inputs for thermistor connection | 1; Type A PTC or Klixon / Thermoclick |
| ● Product function ramp-down (soft stop) | Yes |
| ● between soft starter and motor maximum | 800 m |
| Operating power [hp] for three-phase motors | |
| required spacing with side-by-side mounting | |
| ● Product function slave pointer function | Yes |
| ● of communication module PROFIBUS usable | 3RW5980-0CP00 |
| ● operating current at 40 °C rated value | 38 A |
| ● operating current at 50 °C rated value | 33.5 A |
| ● operating current at 60 °C rated value | 30.5 A |
| ● product function communication function | Yes |
| Buffering time in the event of power failure | |
| Recovery time after overload trip adjustable | 60 ... 1 800 s |
| Type of connectable conductor cross-sections | |
| — finely stranded with core end processing | 2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²) |
| ● Number of digital inputs parameterizable | 4 |
| ● Product function ramp-up (soft starting) | Yes |
| type of voltage of the control supply voltage | AC |
| ● Number of digital outputs parameterizable | 3 |
| ● Product function emergency operation mode | Yes |
| ● of communication module Modbus RTU usable | 3RW5980-0CR00 |
| ● of communication module Modbus TCP usable | 3RW5980-0CT00 |
| maximum permissible voltage for safe isolation | |
| ● Product function via software configurable | Yes |
| ● product function motor overload protection | Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit. |
| Integrated motor overload protection (EF007297) | Electronic, tripping in the event of thermal overload of the |
| Switching capacity current of the relay outputs | |
| ● Product function automatic parameterisation | Yes |
| ● at AWG conductors for control circuit solid | 2x (24 ... 16) |
| ● for main contacts with screw-type terminals | 18 ... 22 lbf·in |
| Product feature integrated bypass contact system | Yes |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| ● product function intrinsic device protection | Yes |
| ● Number of digital outputs not parameterizable | 1 |
| ● Product function via software parameterizable | Yes |
| Control supply current in standby mode rated value | 100 mA |
| Rated operation current Ie at 40 °C Tu (EF007039) | 38 |
| ● Product function adjustable current limitation | Yes |
| Power loss [W] for rated value of the current at AC | |
| ● Operating current at 40 °C rated value minimum | 7.5 A |
| Relative negative tolerance of the operating voltage | -15 % |
| Relative positive tolerance of the operating voltage | 10 % |
| Starting current at close of by-pass contact maximum | 0.2 A |
| contact rating of auxiliary contacts according to UL | R300-B300 |
| ● of communication module PROFINET standard usable | 3RW5980-0CS00 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '250'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '250'] |
| ● Product function operating measured value display | Yes |
| ● Type of electrical connection for control circuit | spring-loaded terminals |
| Design of short-circuit protection for control circuit | 4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply |
| Relative negative tolerance of the operating frequency | -10 % |
| Relative positive tolerance of the operating frequency | 10 % |
| installation altitude at height above sea level maximum | 5 000 m; Derating as of 1000 m, see catalog |
| — usable for High Faults at 460/480 V according to UL | Siemens type: 3RV2742, max.40 A or 3VA51, max. 60 A; Iq max = 65 kA |
| ● Product function programmable control inputs/outputs | Yes |
| ● of communication module PROFINET high-feature usable | 3RW5950-0CH00 |
| Holding current in the by-pass mode operating rated value | 165 mA |
| Rated surrounding temperature without derating (EF007074) | 40 °C |
| type of protection according to ATEX directive 2014/34/EU | II (2)G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb],II (2)D [Ex tb Db] [Ex pxb Db],I (M2) [Ex db Mb] |
| ● Operating voltage at inside-delta circuit rated value | 200 ... 480 V |
| Rated power three-phase motor, inline, at 230 V (EF007053) | 11.0 |
| Rated power three-phase motor, inline, at 400 V (EF007054) | 18.5 |
| — usable for High Faults up to 575/600 V according to UL | Type: Class J / L, max. 150 A; Iq = 100 kA |
| ● at 230 V at inside-delta circuit at 40 °C rated value | 18.5 kW |
| ● at 400 V at inside-delta circuit at 40 °C rated value | 30 kW |
| ● type of electrical connection for main current circuit | screw-type terminals |
| Hardware fault tolerance acc. to IEC 61508 relating to ATEX | 0 |
| — usable for Standard Faults at 460/480 V according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA |
| — usable for Standard Faults at 575/600 V according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA |
| ● Product function removable terminal for control circuit | Yes |
| PFHD with high demand rate acc. to EN 62061 relating to ATEX | 0.0000005 1/h |
| ● of the gG fuse usable at inside-delta circuit up to 500 V | 3NA3824-6; Type of coordination 1, Iq = 65 kA |
| PFDavg with low demand rate acc. to IEC 61508 relating to ATEX | 0.008 |
| — usable for Standard Faults up to 575/600 V according to UL | Type: Class RK5 / K5, max. 150 A; Iq = 5 kA |
| ● Product function Evaluation of thermistor motor protection | Yes; Type A PTC or Klixon / Thermoclick |
| ● at 200/208 V at inside-delta circuit at 50 °C rated value | 15 hp |
| ● at 220/230 V at inside-delta circuit at 50 °C rated value | 20 hp |
| ● at 460/480 V at inside-delta circuit at 50 °C rated value | 40 hp |
| ● of circuit breaker usable at 400 V at inside-delta circuit | 3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10 |
| ● of circuit breaker usable at 500 V at inside-delta circuit | 3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10 |
| Safety Integrity Level (SIL) acc. to IEC 61508 relating to ATEX | SIL1 |
| ● Product function creep speed in both directions of rotation | Yes |
| ● Product function soft starting at heavy starting conditions | Yes |
| Inrush current peak at connect of control supply voltage maximum | 43 A |
| Rated power three-phase motor, inside delta, at 230 V (EF007055) | 18.5 |
| Rated power three-phase motor, inside delta, at 400 V (EF007056) | 30.0 |
| ● for auxiliary and control contacts with screw-type terminals | 7 ... 10.3 lbf·in |
| ● for control circuit finely stranded with core end processing | 2x (0.25 ... 1.5 mm²) |
| ● tightening torque for main contacts with screw-type terminals | 2 ... 2.5 N·m |
| ● type of connectable conductor cross-sections for main contacts | |
| Relative negative tolerance of the control supply voltage frequency | -10 % |
| Relative positive tolerance of the control supply voltage frequency | 10 % |
| Duration of inrush current peak at connect of control supply voltage | 1.6 ms |
| ● certificate of suitability according to ATEX directive 2014/34/EU | BVS 18 ATEX F 003 X |
| Compliance with the substance restrictions according to RoHS directive | Since: 15.02.2018 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Relative negative tolerance of the control supply voltage at AC at 50 Hz | -15 % |
| Relative negative tolerance of the control supply voltage at AC at 60 Hz | -15 % |
| Relative positive tolerance of the control supply voltage at AC at 50 Hz | 10 % |
| Relative positive tolerance of the control supply voltage at AC at 60 Hz | 10 % |
| ● of back-up R fuse link for semiconductor protection usable up to 690 V | 3NE8024-1; Type of coordination 2, Iq = 65 kA |
| Relative negative tolerance of the operating voltage at inside-delta circuit | -15 % |
| Relative positive tolerance of the operating voltage at inside-delta circuit | 10 % |
| ● of full range R fuse link for semiconductor protection usable up to 690 V | 3NE1820-0; Type of coordination 2, Iq = 65 kA |
| — usable for High Faults at 460/480 V at inside-delta circuit according to UL | Siemens type: 3VA51, max. 60 A; Iq max = 65 kA |
| — usable for High Faults at 575/600 V at inside-delta circuit according to UL | Siemens type: 3VA51, max. 60 A; Iq max = 65 kA |
| — usable for High Faults at inside-delta circuit up to 575/600 V according to UL | Type: Class J / L, max. 150 A; Iq = 100 kA |
| ● Tightening torque for auxiliary and control contacts with screw-type terminals | 0.8 ... 1.2 N·m |
| ● at AWG conductors for control circuit finely stranded with core end processing | 2x (24 ... 16) |
| T1 value for proof test interval or service life acc. to IEC 61508 relating to ATEX | 3 y |
| — usable for Standard Faults at 460/480 V at inside-delta circuit according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA |
| — usable for Standard Faults at 575/600 V at inside-delta circuit according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 125 A; Iq = 5 kA |
| — usable for Standard Faults at inside-delta circuit up to 575/600 V according to UL | Type: Class RK5 / K5, max. 150 A; Iq = 5 kA |
| ● Type of connectable conductor cross-sections at AWG conductors for main current circuit solid | 2x (16 ... 12), 2x (14 ... 8) |
| General Product ApprovalEMCFor use in hazardous locationsFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / ShippingType Test Certificates/Test ReportMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide