Service time: Monday to Friday 9:00-18:00
3RW5243-2AC14 - 3RW5243-2AC14 SIEMENS SIRIUS soft starter 200-480 V 210 A, 110-250 V AC spring-type terminals Analog output
In Stock Hot Product

3RW5243-2AC14

3RW5243-2AC14 SIEMENS SIRIUS soft starter 200-480 V 210 A, 110-250 V AC spring-type terminals Analog output

$0.00USD
4679 in stock
Key Specifications
:
EAN:4047621037400
UPC:804766689239
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621037400
UPC804766689239
ETIM5
IDEA4
depth203 mm
width210 mm
UNSPSC15
eClass6
height393 mm
Group CodeR711
trip classCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
wire length
● minimum90 A
● upwards100 mm
Metal FactorLAO-----
● PROFIBUSYes
● at 50 Hz110 ... 250 V
● at 60 Hz110 ... 250 V
● forwards10 mm
Date5/16/2022Subject to change without notice© Copyright Siemens 2022
Product Group4981
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
● backwards0 mm
● downwards75 mm
Commodity Code85371098
Product family3RW52 soft starters
last modified:4/10/2022
service factor1
● CE markingYes
● Modbus RTUYes
● Modbus TCPYes
● auto-RESETYes
Net Weight (kg)11,510 Kg
● EtherNet/IPYes
● PROFIenergyYes; in connection with the PROFINET Standard communication module
● Soft TorqueYes
● UL approvalYes
● at the side5 mm
● of the fuse
● rated value200 ... 480 V
fastening methodscrew fixing
minimum load [%]15 %; Relative to smallest settable Ie
product categoryHybrid switching devices
product function
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
● CSA approvalYes
● manual RESETYes
● remote resetYes; By turning off the control supply voltage
Country of originCzech Republic
Marine / Shippingother
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
operating voltage
product component
tightening torque
● analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
● error logbookYes; Only in conjunction with special accessories
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● pump ramp downYes
● torque controlNo
Function (EF000030)Single direction
Packaging Dimension328,00 x 507,00 x 333,00
Product DescriptionSIRIUS soft starter 200-480 V 210 A, 110-250 V AC spring-type terminals Analog output
ambient temperature
degree of pollution3, acc. to IEC 60947-4-2
operational current
product designationSoft starter
● firmware updateYes
starting voltage [%]30 ... 100 %
stopping voltage [%]50 %; non-adjustable
vibration resistance15 mm to 6 Hz; 2g to 500 Hz
● HMI-High FeatureNo
● during operation-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
● PROFINET standardYes
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
environmental category
● of circuit breaker
Product Lifecycle (PLM)PM300:Active Product
With display (EF000458)-
● for control circuit100 ms
● not parameterizable2
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
General Product ApprovalEMC
Release class (EF006668)Adjustable
adjustable motor current
number of analog outputs1
number of digital inputs1
product type designation3RW52
weight without packaging9.9 kg
● inside-delta circuitYes
Declaration of ConformityTest Certificates
Torque control (EF009215)false
number of digital outputs3
● at 40 °C rated value210 A
● at 50 °C rated value186 A
● at 60 °C rated value170 A
● ramp-down (soft stop)Yes
Export Control RegulationsAL : N / ECCN : N
Internal bypass (EF009214)true
certificate of suitability
● communication functionYes
Standard lead time ex-works100 Day/Days
Surcharge for Raw MaterialsNone
impulse voltage rated value6 kV
number of controlled phases3
tightening torque [lbf·in]
● at 40 °C after startup75 W
● at 50 °C after startup68 W
● at 60 °C after startup63 W
● ramp-up (soft starting)Yes
Package size unit of measureMM
control supply voltage at AC
● at 40 °C during startup3 562 W
● at 50 °C during startup2 979 W
● at 60 °C during startup2 617 W
● for main current circuit100 ms
Substance Prohibitance (Date)02/15/2018
electromagnetic compatibilityin accordance with IEC 60947-4-2
manufacturer's article number
type of electrical connection
● for control circuit solid2x (0.25 ... 1.5 mm²)
● is supported HMI-StandardYes
● motor overload protectionYes; Electronic motor overload protection
● via software configurableYes
insulation voltage rated value600 V
width of connection bar maximum45 mm
● intrinsic device protectionYes
control supply voltage frequency50 ... 60 Hz
● at DC-13 at 24 V rated value1 A
● during storage and transport-40 ... +80 °C
● via software parameterizableNo
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
communication module is supported
● adjustable current limitationYes
● at AC-15 at 250 V rated value3 A
● is supported HMI-High FeatureYes
● of standard HMI module usable3RW5980-0HS00
operating power for 3-phase motors
start-up ramp time of soft starter0 ... 20 s
● at 230 V at 40 °C rated value55 kW
● at 400 V at 40 °C rated value110 kW
● at inside-delta circuit minimum156 A
Degree of protection (IP) (EF005474)IP00
design of the overvoltage protectionVaristor
surge voltage resistance rated value6 kV
● operating measured value displayYes; Only in conjunction with special accessories
Article Number (Market Facing Number)3RW5243-2AC14
Rated operating voltage Ue (EF002418)['200', '480']
Voltage type for actuating (EF008242)AC
current limiting value [%] adjustable130 ... 700 %
● of high feature HMI module usable3RW5980-0HF00
● of the gG fuse usable up to 690 V2x3NA3354-6; Type of coordination 1, Iq = 65 kA
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
● at 200/208 V at 50 °C rated value60 hp
● at 220/230 V at 50 °C rated value60 hp
● at 460/480 V at 50 °C rated value150 hp
● between main and auxiliary circuit600 V
● of circuit breaker usable at 400 V3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
operating power [hp] for 3-phase motors
reference code according to IEC 81346-2Q
● at inside-delta circuit rated value200 ... 480 V
● at the digital inputs at AC maximum100 m
● of communication module Ethernet/IP3RW5980-0CE00
blocking voltage of the thyristor maximum1 600 V
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
● between soft starter and motor maximum800 m
● removable terminal for control circuitYes
operational current at inside-delta circuit
required spacing with side-by-side mounting
● at AWG cables for control circuit solid2x (24 ... 16)
● during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● of communication module PROFIBUS usable3RW5980-0CP00
buffering time in the event of power failure
type of connectable conductor cross-sections
type of voltage of the control supply voltageAC
● evaluation of thermistor motor protectionNo
● of communication module Modbus RTU usable3RW5980-0CR00
● of communication module Modbus TCP usable3RW5980-0CT00
maximum permissible voltage for safe isolation
Integrated motor overload protection (EF007297)-
holding current in bypass operation rated value100 mA
switching capacity current of the relay outputs
utilization category according to IEC 60947-4-2AC 53a
● for main contacts with screw-type terminals14 ... 24 N·m
Rated control supply voltage Us at DC (EF003980)['-', '-']
power loss [W] at AC at current limitation 350 %
product feature integrated bypass contact systemYes
● at rotary coding switch on switch position 190 A
● at rotary coding switch on switch position 298 A
● at rotary coding switch on switch position 3106 A
● at rotary coding switch on switch position 4114 A
● at rotary coding switch on switch position 5122 A
● at rotary coding switch on switch position 6130 A
● at rotary coding switch on switch position 7138 A
● at rotary coding switch on switch position 8146 A
● at rotary coding switch on switch position 9154 A
● for DIN cable lug for main contacts stranded2x (50 ... 240 mm²)
● at rotary coding switch on switch position 10162 A
● at rotary coding switch on switch position 11170 A
● at rotary coding switch on switch position 12178 A
● at rotary coding switch on switch position 13186 A
● at rotary coding switch on switch position 14194 A
● at rotary coding switch on switch position 15202 A
● at rotary coding switch on switch position 16210 A
Rated operation current Ie at 40 °C Tu (EF007039)210
control supply current in standby mode rated value30 mA
power loss [W] for rated value of the current at AC
Region Specific PriceGroup / Headquarter Price Group42S / 42S
contact rating of auxiliary contacts according to ULR300-B300
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
● of communication module PROFINET standard usable3RW5980-0CS00
Rated control supply voltage Us at AC 50HZ (EF003978)['110', '250']
Rated control supply voltage Us at AC 60HZ (EF003979)['110', '250']
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
installation altitude at height above sea level maximum5 000 m; Derating as of 1000 m, see catalog
locked-rotor current at close of bypass contact maximum2.2 A
protection class IP on the front according to IEC 60529IP00; IP20 with cover
— usable for High Faults at 460/480 V according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq max = 65 kA
● for DIN cable lug for main contacts finely stranded2x (70 ... 240 mm²)
Rated surrounding temperature without derating (EF007074)40 °C
Rated power three-phase motor, inline, at 230 V (EF007053)55.0
Rated power three-phase motor, inline, at 400 V (EF007054)110.0
— usable for High Faults up to 575/600 V according to ULType: Class J / L, max. 700 A; Iq = 100 kA
● at 230 V at inside-delta circuit at 40 °C rated value110 kW
● at 400 V at inside-delta circuit at 40 °C rated value200 kW
— usable for Standard Faults at 460/480 V according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq = 10 kA
— usable for Standard Faults at 575/600 V according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq = 10 kA
● of the gG fuse usable at inside-delta circuit up to 500 V2x3NA3354-6; Type of coordination 1, Iq = 65 kA
— usable for Standard Faults up to 575/600 V according to ULType: Class J / L, max. 700 A; Iq = 10 kA
● at 200/208 V at inside-delta circuit at 50 °C rated value100 hp
● at 220/230 V at inside-delta circuit at 50 °C rated value125 hp
● at 460/480 V at inside-delta circuit at 50 °C rated value250 hp
● of circuit breaker usable at 400 V at inside-delta circuit3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
● of circuit breaker usable at 500 V at inside-delta circuit3VA2440-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
Rated power three-phase motor, inside delta, at 230 V (EF007055)110.0
Rated power three-phase motor, inside delta, at 400 V (EF007056)200.0
● for auxiliary and control contacts with screw-type terminals0.8 ... 1.2 N·m
● for control circuit finely stranded with core end processing2x (0.25 ... 1.5 mm²)
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
inrush current peak at application of control supply voltage maximum12.2 A
Compliance with the substance restrictions according to RoHS directiveSince: 15.02.2018
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dibutylbis(pentane-2... CAS-No. 22673-19-4 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dibutylbis(pentane-2,4-dionato-O,O')tinBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dodecamethylcyclohex... CAS-No. 540-97-6 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dodecamethylcyclohexasiloxane (D6)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dodecachloropentacyclo[12... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dodecachloropentacyclo[12.2.1.16,9.02,13.05,10]octadeca-7,15-diene (“Dechlorane Plus”™)covering any of its individual anti- and syn-isomers or any combination thereofBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
duration of inrush current peak at application of control supply voltage2.2 ms
relative negative tolerance of the control supply voltage at AC at 50 Hz-15 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz10 %
relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
● for inside-delta circuit at rotary coding switch on switch position 1156 A
● for inside-delta circuit at rotary coding switch on switch position 2170 A
● for inside-delta circuit at rotary coding switch on switch position 3184 A
● for inside-delta circuit at rotary coding switch on switch position 4197 A
● for inside-delta circuit at rotary coding switch on switch position 5211 A
● for inside-delta circuit at rotary coding switch on switch position 6225 A
● for inside-delta circuit at rotary coding switch on switch position 7239 A
● for inside-delta circuit at rotary coding switch on switch position 8253 A
● for inside-delta circuit at rotary coding switch on switch position 9267 A
● for inside-delta circuit at rotary coding switch on switch position 10281 A
● for inside-delta circuit at rotary coding switch on switch position 11294 A
● for inside-delta circuit at rotary coding switch on switch position 12308 A
● for inside-delta circuit at rotary coding switch on switch position 13322 A
● for inside-delta circuit at rotary coding switch on switch position 14336 A
● for inside-delta circuit at rotary coding switch on switch position 15350 A
● for inside-delta circuit at rotary coding switch on switch position 16364 A
● of back-up R fuse link for semiconductor protection usable up to 690 V3NE3333; Type of coordination 2, Iq = 65 kA
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
● of full range R fuse link for semiconductor protection usable up to 690 V3NE1230-2; Type of coordination 2, Iq = 65 kA
● at AWG cables for control circuit finely stranded with core end processing2x (24 ... 16)
— usable for High Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq max = 65 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 700 A; Iq = 100 kA
— usable for Standard Faults at 460/480 V at inside-delta circuit according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq = 10 kA
— usable for Standard Faults at 575/600 V at inside-delta circuit according to ULSiemens type: 3VA53, max. 400 A or 3VA54, max. 600 A; Iq = 10 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, max. 700 A; Iq = 10 kA
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

SIRIUS soft starter 200-480 V 210 A, 110-250 V AC Spring connection Analog output. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top