| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209611085 |
| UPC | Not available |
| ETIM | 4 |
| IDEA | 4 |
| Depth | mm |
| Notes | Sucessor:Nachfolger ist SIRIUS 3RW5 |
| Width | mm |
| Height | mm |
| UNSPSC | 15 |
| eClass | 6 |
| ● solid | |
| Group Code | R711 |
| Price Group | 42G |
| ● upwards | mm |
| Metal Factor | LAO----- |
| ● at 230 V | |
| ● at 400 V | |
| ● stranded | |
| Miscellaneous | Special Test Certificate |
| Mounting type | |
| Product Group | 3727 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● downwards | mm |
| Commodity Code | 85371098 |
| Product family | Ordering Data Overview |
| last modified: | 07/07/2020 |
| ● Thyristors | |
| Net Weight (kg) | 8,125 Kg |
| Product feature | |
| ● at the side | mm |
| Minimum load [%] | % |
| Product function | |
| ● at 220/230 V | |
| ● at 460/480 V | |
| Country of origin | Czech Republic |
| Mounting position | |
| Operating current | |
| LKZ_FDB/ CatalogID | CC-IC10 |
| PLM Effective Date | Product phase-out since: 01.10.2019 |
| Packaging Quantity | 1 |
| Product brand name | |
| ● External reset | |
| ● during storage | °C |
| Ambient temperature | |
| Degree of pollution | |
| Function (EF000030) | Single direction |
| Packaging Dimension | 321,00 x 342,00 x 221,00 |
| Product Description | SIRIUS soft starter S12 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals without bypass !!! Phased-out product !!! Successor is SIRIUS 3RW5. |
| Product designation | |
| Protection class IP | |
| Wire length maximum | m |
| ● finely stranded | |
| Derating temperature | °C |
| ● during operation | °C |
| ● for main contacts | |
| Environmental category | |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| With display (EF000458) | - |
| General Product Approval | EMC |
| Release class (EF006668) | - |
| ● at 50 Hz rated value | V |
| ● at 60 Hz rated value | V |
| ● inside-delta circuit | |
| Declaration of Conformity | Test Certificates |
| Torque control (EF009215) | - |
| ● at 40 °C rated value | A |
| ● at 50 °C rated value | A |
| ● at 60 °C rated value | A |
| Export Control Regulations | AL : N / ECCN : N |
| Internal bypass (EF009214) | - |
| ● for auxiliary contacts | |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| ● for main current circuit | |
| Size of engine control device | |
| Type of electrical connection | |
| ● motor overload protection | |
| Control supply voltage 1 at AC | |
| Insulation voltage rated value | V |
| Product Dimensions (W x L x H) | Not available |
| ● using both clamping points | |
| Operating frequency rated value | Hz |
| ● Intrinsic device protection | |
| Display version for fault signal | |
| ● Adjustable current limitation | |
| ● using the back clamping point | |
| ● using the front clamping point | |
| Degree of protection (IP) (EF005474) | IP00 |
| Product component Motor brake output | |
| ● during storage acc. to IEC 60721 | |
| ● integrated bypass contact system | |
| Article Number (Market Facing Number) | 3RW4073-6AB44 |
| Rated operating voltage Ue (EF002418) | ['200', '460'] |
| Reference code acc. to DIN EN 61346-2 | |
| Voltage type for actuating (EF008242) | AC |
| Degree of protection (NEMA) (EF011959) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● during operation acc. to IEC 60721 | |
| ● during transport acc. to IEC 60721 | |
| Number of poles for main current circuit | |
| Required spacing with side-by-side mounting | |
| Number of CO contacts for auxiliary contacts | |
| Number of NC contacts for auxiliary contacts | |
| Number of NO contacts for auxiliary contacts | |
| ● finely stranded with core end processing | |
| Type of voltage of the control supply voltage | |
| — at standard circuit at 40 °C rated value | W |
| — at standard circuit at 50 °C rated value | hp |
| ● Evaluation of thermistor motor protection | |
| ● for auxiliary and control current circuit | |
| Control supply voltage frequency 1 rated value | Hz |
| Control supply voltage frequency 2 rated value | Hz |
| Mechanical power output for three-phase motors | |
| Installation altitude at height above sea level | m |
| Integrated motor overload protection (EF007297) | true |
| ● finely stranded without core end processing | |
| Continuous operating current [% of Ie] at 40 °C | % |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| Operating voltage at standard circuit rated value | V |
| Rated operation current Ie at 40 °C Tu (EF007039) | 134 |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '230'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '230'] |
| Relative negative tolerance of the operating frequency | % |
| Relative positive tolerance of the operating frequency | % |
| Rated surrounding temperature without derating (EF007074) | 40 |
| Rated power three-phase motor, inline, at 230 V (EF007053) | 37.0 |
| Rated power three-phase motor, inline, at 400 V (EF007054) | 75.0 |
| Yielded mechanical performance [hp] for three-phase AC motor | |
| Type of connectable conductor cross-sections at AWG conductors | |
| Rated power three-phase motor, inside delta, at 230 V (EF007055) | - |
| Rated power three-phase motor, inside delta, at 400 V (EF007056) | - |
| Relative negative tolerance of the control supply voltage frequency | % |
| Relative positive tolerance of the control supply voltage frequency | % |
| Type of connectable conductor cross-sections for auxiliary contacts | |
| ● for auxiliary contacts finely stranded with core end processing | |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| Power loss [W] at operating current at 40 °C during operation typical | W |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Relative negative tolerance of the control supply voltage at AC at 50 Hz | % |
| Relative negative tolerance of the control supply voltage at AC at 60 Hz | % |
| Relative negative tolerance of the operating voltage at standard circuit | % |
| Relative positive tolerance of the control supply voltage at AC at 50 Hz | % |
| Relative positive tolerance of the control supply voltage at AC at 60 Hz | % |
| Relative positive tolerance of the operating voltage at standard circuit | % |
| Adjustable motor current for motor overload protection minimum rated value | A |
| Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 | |
| Type of connectable conductor cross-sections for DIN cable lug for main contacts | |
| Type of connectable conductor cross-sections at AWG conductors for main contacts for box terminal | |
| Type of connectable conductor cross-sections for main contacts for box terminal using both clamping points | |
| Type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point | |
| Type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point | |
| Yielded mechanical performance [hp] for three-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | hp |
| General Product ApprovalEMCDeclaration of ConformityDeclaration of ConformityTest CertificatesMarine / ShippingotherMiscellaneousSpecial Test CertificateConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide