Service time: Monday to Friday 9:00-18:00
3RW4073-6AB44 - 3RW4073-6AB44 SIEMENS SIRIUS soft starter S12 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw termina..
In Stock Hot Product

3RW4073-6AB44

3RW4073-6AB44 SIEMENS SIRIUS soft starter S12 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw termina..

$0.00USD
3248 in stock
Key Specifications
:Value
EAN:4011209611085
UPC:Not available
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209611085
UPCNot available
ETIM4
IDEA4
Depthmm
NotesSucessor:Nachfolger ist SIRIUS 3RW5
Widthmm
Heightmm
UNSPSC15
eClass6
● solid
Group CodeR711
Price Group42G
● upwardsmm
Metal FactorLAO-----
● at 230 V
● at 400 V
● stranded
MiscellaneousSpecial Test Certificate
Mounting type
Product Group3727
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● downwardsmm
Commodity Code85371098
Product familyOrdering Data Overview
last modified:07/07/2020
● Thyristors
Net Weight (kg)8,125 Kg
Product feature
● at the sidemm
Minimum load [%]%
Product function
● at 220/230 V
● at 460/480 V
Country of originCzech Republic
Mounting position
Operating current
LKZ_FDB/ CatalogIDCC-IC10
PLM Effective DateProduct phase-out since: 01.10.2019
Packaging Quantity1
Product brand name
● External reset
● during storage°C
Ambient temperature
Degree of pollution
Function (EF000030)Single direction
Packaging Dimension321,00 x 342,00 x 221,00
Product DescriptionSIRIUS soft starter S12 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals without bypass !!! Phased-out product !!! Successor is SIRIUS 3RW5.
Product designation
Protection class IP
Wire length maximumm
● finely stranded
Derating temperature°C
● during operation°C
● for main contacts
Environmental category
Product Lifecycle (PLM)PM400:Phase Out Started
With display (EF000458)-
General Product ApprovalEMC
Release class (EF006668)-
● at 50 Hz rated valueV
● at 60 Hz rated valueV
● inside-delta circuit
Declaration of ConformityTest Certificates
Torque control (EF009215)-
● at 40 °C rated valueA
● at 50 °C rated valueA
● at 60 °C rated valueA
Export Control RegulationsAL : N / ECCN : N
Internal bypass (EF009214)-
● for auxiliary contacts
Standard lead time ex-works5 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
● for main current circuit
Size of engine control device
Type of electrical connection
● motor overload protection
Control supply voltage 1 at AC
Insulation voltage rated valueV
Product Dimensions (W x L x H)Not available
● using both clamping points
Operating frequency rated valueHz
● Intrinsic device protection
Display version for fault signal
● Adjustable current limitation
● using the back clamping point
● using the front clamping point
Degree of protection (IP) (EF005474)IP00
Product component Motor brake output
● during storage acc. to IEC 60721
● integrated bypass contact system
Article Number (Market Facing Number)3RW4073-6AB44
Rated operating voltage Ue (EF002418)['200', '460']
Reference code acc. to DIN EN 61346-2
Voltage type for actuating (EF008242)AC
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
● during operation acc. to IEC 60721
● during transport acc. to IEC 60721
Number of poles for main current circuit
Required spacing with side-by-side mounting
Number of CO contacts for auxiliary contacts
Number of NC contacts for auxiliary contacts
Number of NO contacts for auxiliary contacts
● finely stranded with core end processing
Type of voltage of the control supply voltage
— at standard circuit at 40 °C rated valueW
— at standard circuit at 50 °C rated valuehp
● Evaluation of thermistor motor protection
● for auxiliary and control current circuit
Control supply voltage frequency 1 rated valueHz
Control supply voltage frequency 2 rated valueHz
Mechanical power output for three-phase motors
Installation altitude at height above sea levelm
Integrated motor overload protection (EF007297)true
● finely stranded without core end processing
Continuous operating current [% of Ie] at 40 °C%
Rated control supply voltage Us at DC (EF003980)['-', '-']
Operating voltage at standard circuit rated valueV
Rated operation current Ie at 40 °C Tu (EF007039)134
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '230']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '230']
Relative negative tolerance of the operating frequency%
Relative positive tolerance of the operating frequency%
Rated surrounding temperature without derating (EF007074)40
Rated power three-phase motor, inline, at 230 V (EF007053)37.0
Rated power three-phase motor, inline, at 400 V (EF007054)75.0
Yielded mechanical performance [hp] for three-phase AC motor
Type of connectable conductor cross-sections at AWG conductors
Rated power three-phase motor, inside delta, at 230 V (EF007055)-
Rated power three-phase motor, inside delta, at 400 V (EF007056)-
Relative negative tolerance of the control supply voltage frequency%
Relative positive tolerance of the control supply voltage frequency%
Type of connectable conductor cross-sections for auxiliary contacts
● for auxiliary contacts finely stranded with core end processing
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Power loss [W] at operating current at 40 °C during operation typicalW
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Relative negative tolerance of the control supply voltage at AC at 50 Hz%
Relative negative tolerance of the control supply voltage at AC at 60 Hz%
Relative negative tolerance of the operating voltage at standard circuit%
Relative positive tolerance of the control supply voltage at AC at 50 Hz%
Relative positive tolerance of the control supply voltage at AC at 60 Hz%
Relative positive tolerance of the operating voltage at standard circuit%
Adjustable motor current for motor overload protection minimum rated valueA
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750
Type of connectable conductor cross-sections for DIN cable lug for main contacts
Type of connectable conductor cross-sections at AWG conductors for main contacts for box terminal
Type of connectable conductor cross-sections for main contacts for box terminal using both clamping points
Type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point
Type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point
Yielded mechanical performance [hp] for three-phase AC motor at 200/208 V at standard circuit at 50 °C rated valuehp
General Product ApprovalEMCDeclaration of ConformityDeclaration of ConformityTest CertificatesMarine / ShippingotherMiscellaneousSpecial Test CertificateConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide