3RW3036-2BB04 - 3RW3036-2BB04 SIEMENS SIRIUS soft starter S2 45 A, 22 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type t..
In Stock Hot Product

3RW3036-2BB04

3RW3036-2BB04 SIEMENS SIRIUS soft starter S2 45 A, 22 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type t..

$0.00USD
3812 in stock
Key Specifications
:Confirmation
EAN:4011209719323
UPC:754554958255
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209719323
UPC754554958255
ETIM5
IDEA4
depthmm
widthmm
UNSPSC14
eClass6
heightmm
● solid
Group CodeR711
● upwardsmm
Confirmation
Metal FactorLBO-----
● at 230 V
● at 400 V
● stranded
Date5/13/2022Subject to change without notice© Copyright Siemens 2022
Product Group5345
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
● downwardsmm
Commodity Code85371098
Product family3RW30 soft starters
last modified:1/16/2022
● thyristors
Net Weight (kg)1,169 Kg
product feature
● at the sidemm
fastening method
minimum load [%]%
product function
● at 220/230 V
● at 460/480 V
Country of originCzech Republic
mounting position
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand name
● during storage°C
● external reset
Function (EF000030)Single direction
Packaging Dimension169,00 x 197,00 x 71,00
Product DescriptionSIRIUS soft starter S2 45 A, 22 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC spring-type terminals
ambient temperature
degree of pollution
operational current
product designation
wire length maximumm
derating temperature°C
● during operation°C
environmental category
Product Lifecycle (PLM)PM300:Active Product
With display (EF000458)-
General Product ApprovalEMC
Release class (EF006668)-
● at 50 Hz rated valueV
● at 60 Hz rated valueV
● inside-delta circuit
Declaration of ConformityTest Certificates
Torque control (EF009215)-
● at 40 °C rated valueA
● at 50 °C rated valueA
● at 60 °C rated valueA
Export Control RegulationsAL : N / ECCN : N
Internal bypass (EF009214)-
● for auxiliary contacts
Standard lead time ex-works50 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
● for main current circuit
size of engine control device
type of electrical connection
● motor overload protection
control supply voltage 1 at AC
insulation voltage rated valueV
● using both clamping points
operating frequency rated valueHz
● intrinsic device protection
display version for fault signal
● adjustable current limitation
● using the back clamping point
● using the front clamping point
Degree of protection (IP) (EF005474)IP00
product component motor brake output
● integrated bypass contact system
Article Number (Market Facing Number)3RW3036-2BB04
Rated operating voltage Ue (EF002418)['200', '480']
Voltage type for actuating (EF008242)AC/DC
● for auxiliary and control circuit
Degree of protection (NEMA) (EF011959)-
WEEE (2012/19/EU) Take-Back ObligationYes
reference code according to EN 61346-2
number of poles for main current circuit
● during storage according to IEC 60721
control supply voltage 1 at DC rated valueV
required spacing with side-by-side mounting
● during operation according to IEC 60721
● during transport according to IEC 60721
number of CO contacts for auxiliary contacts
number of NC contacts for auxiliary contacts
number of NO contacts for auxiliary contacts
● finely stranded with core end processing
type of voltage of the control supply voltage
— at standard circuit at 40 °C rated valuekW
— at standard circuit at 50 °C rated valuehp
● evaluation of thermistor motor protection
control supply voltage frequency 1 rated valueHz
control supply voltage frequency 2 rated valueHz
Integrated motor overload protection (EF007297)false
installation altitude at height above sea levelm
Rated control supply voltage Us at DC (EF003980)['-', '24']
continuous operating current [% of Ie] at 40 °C%
operating voltage at standard circuit rated valueV
yielded mechanical performance for 3-phase motors
Rated operation current Ie at 40 °C Tu (EF007039)45
Region Specific PriceGroup / Headquarter Price Group42G / 42G
contact rating of auxiliary contacts according to UL
touch protection on the front according to IEC 60529
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '24']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '24']
relative negative tolerance of the operating frequency%
relative positive tolerance of the operating frequency%
protection class IP on the front according to IEC 60529
yielded mechanical performance [hp] for 3-phase AC motor
Rated surrounding temperature without derating (EF007074)40
Rated power three-phase motor, inline, at 230 V (EF007053)11.0
Rated power three-phase motor, inline, at 400 V (EF007054)22.0
type of connectable conductor cross-sections at AWG cables
relative negative tolerance of the control supply voltage at DC%
relative positive tolerance of the control supply voltage at DC%
Rated power three-phase motor, inside delta, at 230 V (EF007055)-
Rated power three-phase motor, inside delta, at 400 V (EF007056)-
relative negative tolerance of the control supply voltage frequency%
relative positive tolerance of the control supply voltage frequency%
type of connectable conductor cross-sections for auxiliary contacts
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
REACH Art. 33 Duty to inform according to the current list of candidatesPerfluorobutane sulfonic ... > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Perfluorobutane sulfonic acid (PFBS) and its saltsBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
power loss [W] at operational current at 40 °C during operation typicalW
relative negative tolerance of the control supply voltage at AC at 50 Hz%
relative negative tolerance of the control supply voltage at AC at 60 Hz%
relative negative tolerance of the operating voltage at standard circuit%
relative positive tolerance of the control supply voltage at AC at 50 Hz%
relative positive tolerance of the control supply voltage at AC at 60 Hz%
relative positive tolerance of the operating voltage at standard circuit%
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750
type of connectable conductor cross-sections at AWG cables for main contacts for box terminal
type of connectable conductor cross-sections for main contacts for box terminal using both clamping points
type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated valuehp
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherRailwayType Test Certificates/Test ReportSpecial Test CertificateConfirmationMiscellaneousVibration and ShockRailwayConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top