Technical Specifications

ParameterValue
EAN4047621062532
UPCNot available
ETIM5
IDEA4
depth97 mm
otherRailway
width45 mm
UNSPSC15
eClass6
height97 mm
B10 value
Group CodeR711
trip classCLASS 10
— upwards30 mm
● at AC-3
Metal FactorLBP-----
— forwards0 mm
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5333
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— backwards0 mm
— downwards30 mm
Commodity Code85362010
Product familySIRIUS 3RV2 motor starter protectors
last modified:1/27/2022
Net Weight (kg)0,291 Kg
operating power
— at the side9 mm
● rated value690 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Marine / Shippingother
mounting positionany
operating voltage
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIRIUS
● during storage-50 ... +80 °C
Packaging Dimension50,00 x 102,00 x 104,00
Product DescriptionCircuit breaker size S0 For transformer protection A-release 0.14...0.2 A Short-circuit release 4.2 A Screw terminal Standard switching capacity
ambient temperature
operating frequency
operational current
product designationCircuit breaker
● at AC-3 maximum15 1/h
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productFor transformer protection
— solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
Rated voltage (EF003977)-
product type designation3RV2
temperature compensation-20 ... +60 °C
— at 230 V rated value0 kW
— at 400 V rated value0.1 kW
— at 500 V rated value0.1 kW
— at 690 V rated value0.1 kW
● at 240 V rated value100 kA
● at 400 V rated value100 kA
● at 480 V rated value0.2 A
● at 500 V rated value100 kA
● at 600 V rated value0.2 A
● at 690 V rated value100 kA
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : EAR99
Number of poles (EF001391)3
● ground fault detectionNo
Standard lead time ex-works70 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 5 to 6 mm
size of the circuit-breakerS0
size of the screwdriver tipPozidriv size 2
● for live parts at 400 V
● for live parts at 500 V
● for live parts at 690 V
● phase failure detectionYes
Package size unit of measureMM
UK Declaration of Conformity
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
Device construction (EF008240)Built-in device fixed built-in technique
design of the overload releasethermal
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value100 kA
● at AC at 500 V rated value100 kA
● at AC at 690 V rated value100 kA
Motor drive optional (EF007386)false
operating frequency rated value50 ... 60 Hz
operational current rated value0.2 A
● at AC-3 rated value maximum690 V
● for grounded parts at 400 V
● for grounded parts at 500 V
● for grounded parts at 690 V
design of the short-circuit tripmagnetic
proportion of dangerous failures
● at AC in hot operating state5.5 W
● at AC-3 at 400 V rated value0.2 A
● of the main contacts typical100 000
Motor drive integrated (EF006697)false
● of auxiliary contacts typical100 000
Type of control element (EF006976)-
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
● at AWG cables for main contacts2x (16 ... 12), 2x (14 ... 8)
Degree of protection (IP) (EF005474)-
display version for switching statusHandle
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RV2421-0BA10
Rated permanent current Iu (EF001389)0.2
With under voltage release (EF007518)false
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)false
● between main and auxiliary circuit400 V
reference code according to IEC 81346-2Q
number of poles for main current circuit3
product function short circuit protectionYes
● at AC in hot operating state per pole1.8 W
mechanical service life (switching cycles)
Overload release current setting (EF002336)['0.14', '0.2']
Integrated earth fault protection (EF007296)false
design of the thread of the connection screw
full-load current (FLA) for 3-phase AC motor
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
shock resistance according to IEC 60068-2-2725g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
power loss [W] for rated value of the current
● with low demand rate according to SN 3192050 %
Complete device with protection unit (EF008906)-
electrical endurance (switching cycles) typical100 000
● for main contacts with screw-type terminals2 ... 2.5 N·m
● with high demand rate according to SN 319205 000
size of contactor can be combined company-specificS00, S0
DIN rail (top hat rail) mounting optional (EF008904)-
Region Specific PriceGroup / Headquarter Price Group41E / 41E
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
breaking capacity maximum short-circuit current (Icu)
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Suitable for DIN rail (top hat rail) mounting (EF007250)FALSE
Type of electrical connection of main circuit (EF006819)-
Position of connection for main current circuit (EF006671)-
Adjustment range undelayed short-circuit release (EF007131)['4.2', '4.2']
arrangement of electrical connectors for main current circuitTop and bottom
breaking capacity operating short-circuit current (Ics) at AC
Number of auxiliary contacts as change-over contact (EF003531)0
insulation voltage with degree of pollution 3 at AC rated value690 V
response value current of instantaneous short-circuit trip unit4.2 A
Number of auxiliary contacts as normally open contact (EF001376)0
Number of auxiliary contacts as normally closed contact (EF001377)0
Adjustment range short-term delayed short-circuit release (EF007129)['-', '-']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)100.0
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
product component removable terminal for auxiliary and control circuitNo
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable current response value current of the current-dependent overload release0.14 ... 0.2 A
maximum permissible voltage for safe isolation in networks with grounded star point
General Product ApprovalConfirmationKCDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherConfirmationotherRailwayVibration and ShockConfirmationGeneral Product Approval

Product Description

S0 size circuit breaker for transformer protection Overload trigger with current delay 0.14...0.2 A Short circuit trigger 4.2 A screw terminal Standard cutting power. Manufactured to order. Non-Cancel
Key Features