Service time: Monday to Friday 9:00-18:00
3RV2411-0BA15 - 3RV2411-0BA15 SIEMENS Circuit breaker size S00 for transformer protection A-release 0.14...0.2 A N-release 4..
In Stock Hot Product

3RV2411-0BA15

3RV2411-0BA15 SIEMENS Circuit breaker size S00 for transformer protection A-release 0.14...0.2 A N-release 4..

$0.00USD
3328 in stock
Key Specifications
:Confirmation
EAN:4011209841390
UPC:662643923810
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209841390
UPC662643923810
ETIM5
IDEA4
depth97 mm
otherRailway
width45 mm
UNSPSC14
eClass6
height97 mm
B10 value
Group CodeR711
trip classCLASS 10
— upwards30 mm
● at 24 V2 A
● at 60 V0.15 A
● at AC-3
Date5/7/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAP-----
— forwards0 mm
● at 120 V0.5 A
● at 125 V0.5 A
● at 230 V0.5 A
Product Group5332
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— backwards0 mm
— downwards30 mm
Commodity Code85362010
Product familySIRIUS 3RV2 motor starter protectors
last modified:1/27/2022
Net Weight (kg)0,293 Kg
operating power
— at the side9 mm
● rated value690 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Marine / Shippingother
mounting positionany
operating voltage
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIRIUS
● during storage-50 ... +80 °C
Packaging Dimension49,00 x 102,00 x 102,00
Product DescriptionCircuit breaker size S00 for transformer protection A-release 0.14...0.2 A N-release 4.2 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC
ambient temperature
operating frequency
operational current
product designationCircuit breaker
● at AC-3 maximum15 1/h
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productFor transformer protection
— solid or stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
Rated voltage (EF003977)-
product type designation3RV2
temperature compensation-20 ... +60 °C
— at 230 V rated value0 kW
— at 400 V rated value0.1 kW
— at 500 V rated value0.1 kW
— at 690 V rated value0.1 kW
● at 240 V rated value100 kA
● at 400 V rated value100 kA
● at 480 V rated value0.2 A
● at 500 V rated value100 kA
● at 600 V rated value0.2 A
● at 690 V rated value100 kA
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
● for auxiliary contacts
● ground fault detectionNo
Standard lead time ex-works70 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 5 to 6 mm
size of the circuit-breakerS00
size of the screwdriver tipPozidriv size 2
● for live parts at 400 V
● for live parts at 500 V
● for live parts at 690 V
● phase failure detectionYes
Package size unit of measureMM
UK Declaration of Conformity
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
Device construction (EF008240)Built-in device fixed built-in technique
design of the auxiliary switchtransverse
design of the overload releasethermal
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value100 kA
● at AC at 500 V rated value100 kA
● at AC at 690 V rated value100 kA
Motor drive optional (EF007386)false
operating frequency rated value50 ... 60 Hz
operational current rated value0.2 A
● at AC-3 rated value maximum690 V
● for grounded parts at 400 V
● for grounded parts at 500 V
● for grounded parts at 690 V
design of the short-circuit tripmagnetic
proportion of dangerous failures
● at AC in hot operating state5.5 W
● at AC-3 at 400 V rated value0.2 A
● of the main contacts typical100 000
Motor drive integrated (EF006697)false
● of auxiliary contacts typical100 000
Type of control element (EF006976)Toggle
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
● at AWG cables for main contacts2x (18 ... 14), 2x 12
Degree of protection (IP) (EF005474)IP20
display version for switching statusHandle
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RV2411-0BA15
Rated permanent current Iu (EF001389)0.2
With under voltage release (EF007518)false
● for auxiliary and control circuitscrew-type terminals
WEEE (2012/19/EU) Take-Back ObligationYes
With switched-off indicator (EF007006)false
● between main and auxiliary circuit400 V
reference code according to IEC 81346-2Q
number of poles for main current circuit3
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
product function short circuit protectionYes
● at AC in hot operating state per pole1.8 W
● of the auxiliary and control contactsM3
mechanical service life (switching cycles)
Overload release current setting (EF002336)['0.14', '0.2']
Integrated earth fault protection (EF007296)false
design of the thread of the connection screw
full-load current (FLA) for 3-phase AC motor
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
shock resistance according to IEC 60068-2-2725g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
power loss [W] for rated value of the current
● with low demand rate according to SN 3192050 %
Complete device with protection unit (EF008906)-
electrical endurance (switching cycles) typical100 000
● for main contacts with screw-type terminals0.8 ... 1.2 N·m
● with high demand rate according to SN 319205 000
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
size of contactor can be combined company-specificS00, S0
DIN rail (top hat rail) mounting optional (EF008904)-
Region Specific PriceGroup / Headquarter Price Group41E / 41E
contact rating of auxiliary contacts according to ULC300 / R300
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
breaking capacity maximum short-circuit current (Icu)
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Suitable for DIN rail (top hat rail) mounting (EF007250)FALSE
Type of electrical connection of main circuit (EF006819)Screw connection
Position of connection for main current circuit (EF006671)Other
Adjustment range undelayed short-circuit release (EF007131)['4.2', '4.2']
arrangement of electrical connectors for main current circuitTop and bottom
breaking capacity operating short-circuit current (Ics) at AC
Number of auxiliary contacts as change-over contact (EF003531)0
insulation voltage with degree of pollution 3 at AC rated value690 V
response value current of instantaneous short-circuit trip unit4.2 A
Number of auxiliary contacts as normally open contact (EF001376)1
● for short-circuit protection of the auxiliary switch requiredFuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)
Number of auxiliary contacts as normally closed contact (EF001377)1
Adjustment range short-term delayed short-circuit release (EF007129)['-', '-']
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048)100.0
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
product component removable terminal for auxiliary and control circuitNo
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable current response value current of the current-dependent overload release0.14 ... 0.2 A
maximum permissible voltage for safe isolation in networks with grounded star point
General Product ApprovalConfirmationKCDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationotherRailwayVibration and ShockConfirmationGeneral Product Approval

Product Description

SIRIUS Innovations S00 circuit breaker, transformer protection Protection L0, 14...0, 2A, Protection I4, 2A, screw connection, Standard cutting power 1NA+NC. Manufactured to order. Non-Cancelable Non-
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top