Key Specifications
:
EAN:4011209946064
UPC:804766202667
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209946064
UPC804766202667
ETIM5
IDEA4
depth149 mm
otherRailway
width55 mm
UNSPSC15
eClass6
height140 mm
B10 value
Group CodeR711
— upwards50 mm
● at AC-3
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLBP-----
— forwards0 mm
● at 240 Vnone required
● at 400 V160
● at 500 V125
● at 690 V100
Product Group5334
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards50 mm
Commodity Code85362010
Product familySIRIUS 3RV2 motor starter protectors
last modified:1/27/2022
Net Weight (kg)1,152 Kg
operating power
— at the side10 mm
● rated value690 V
Depth (EF000049)97.0
Width (EF000008)55.0
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Height (EF000040)140.0
Marine / Shippingother
mounting positionany
operating voltage
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIRIUS
● during storage-50 ... +80 °C
Packaging Dimension62,00 x 147,00 x 167,00
Product DescriptionCircuit breaker size S2 for starter combination Rated current 52 A N-release 741 A screw terminal Standard switching capacity
ambient temperature
operating frequency
operational current
product designationCircuit breaker
● at AC-3 maximum15 1/h
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productFor starter combinations
— solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
product type designation3RV2
— at 230 V rated value15 kW
— at 400 V rated value22 kW
— at 500 V rated value30 kW
— at 690 V rated value45 kW
● at 240 V rated value100 kA
● at 400 V rated value30 kA
● at 480 V rated value52 A
● at 500 V rated value4 kA
● at 600 V rated value52 A
● at 690 V rated value2 kA
● for 3-phase AC motor
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
● ground fault detectionNo
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 5 to 6 mm
size of the circuit-breakerS2
size of the screwdriver tipPozidriv size 2
● for live parts at 400 V
● for live parts at 500 V
● for live parts at 690 V
● phase failure detectionNo
Package size unit of measureMM
UK Declaration of Conformity
— at 110/120 V rated value5 hp
— at 200/208 V rated value15 hp
— at 220/230 V rated value20 hp
— at 460/480 V rated value40 hp
— at 575/600 V rated value50 hp
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/15/2014
type of electrical connection
● for single-phase AC motor
Device construction (EF008240)Built-in device fixed built-in technique
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value65 kA
● at AC at 500 V rated value8 kA
● at AC at 690 V rated value4 kA
Switch off technique (EF007007)Magnetic
operating frequency rated value50 ... 60 Hz
operational current rated value52 A
● at AC-3 rated value maximum690 V
● for grounded parts at 400 V
● for grounded parts at 500 V
● for grounded parts at 690 V
design of the short-circuit tripmagnetic
proportion of dangerous failures
● at AC in hot operating state24.5 W
● at AC-3 at 400 V rated value52 A
● of the main contacts typical50 000
● of auxiliary contacts typical50 000
Phase failure sensitive (EF007400)false
Rated operating voltage (EF001435)['690', '690']
Type of control element (EF006976)Turn button
With thermal protection (EF006233)-
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
yielded mechanical performance [hp]
● at AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
Degree of protection (IP) (EF005474)IP20
display version for switching statusHandle
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RV2331-4WC10
Rated permanent current Iu (EF001389)52.0
WEEE (2012/19/EU) Take-Back ObligationYes
● between main and auxiliary circuit400 V
reference code according to IEC 81346-2Q
number of poles for main current circuit3
product function short circuit protectionYes
● at AC in hot operating state per pole8.2 W
mechanical service life (switching cycles)
Overload release current setting (EF002336)['-', '-']
With integrated auxiliary switch (EF001387)false
design of the thread of the connection screw
full-load current (FLA) for 3-phase AC motor
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
shock resistance according to IEC 60068-2-2725g / 11 ms Sinus
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
power loss [W] for rated value of the current
● with low demand rate according to SN 3192050 %
Rated operation power at AC-3, 230 V (EF007025)15.0
Rated operation power at AC-3, 400 V (EF001364)22.0
electrical endurance (switching cycles) typical50 000
● for main contacts with screw-type terminals3 ... 4.5 N·m
● with high demand rate according to SN 319205 000
With integrated under voltage release (EF001390)false
size of contactor can be combined company-specificS2
Region Specific PriceGroup / Headquarter Price Group41E / 41E
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
breaking capacity maximum short-circuit current (Icu)
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
Adjustment range undelayed short-circuit release (EF007131)['741', '741']
arrangement of electrical connectors for main current circuitTop and bottom
breaking capacity operating short-circuit current (Ics) at AC
insulation voltage with degree of pollution 3 at AC rated value690 V
response value current of instantaneous short-circuit trip unit741 A
Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049)65.0
Compliance with the substance restrictions according to RoHS directiveSince: 15.10.2014
product component removable terminal for auxiliary and control circuitNo
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
maximum permissible voltage for safe isolation in networks with grounded star point
design of the fuse link for IT network for short-circuit protection of the main circuit
General Product ApprovalConfirmationKCDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationotherRailwayVibration and ShockConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top