Key Specifications
:
EAN:4011209766785
UPC:662643923667
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209766785
UPC662643923667
ETIM5
IDEA4
depth97 mm
otherRailway
width45 mm
UNSPSC14
eClass6
height119 mm
B10 value
Group CodeR711
— upwards30 mm
● at AC-3
Metal FactorLBP-----
— forwards0 mm
● at 400 VgL/gG 63 A
● at 500 VgL/gG 50 A
● at 690 VgL/gG 50 A
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5333
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards30 mm
Commodity Code85362010
Product familySIRIUS 3RV2 motor starter protectors
last modified:10/7/2021
Net Weight (kg)0,410 Kg
operating power
— at the side9 mm
● rated value690 V
Depth (EF000049)97.0
Width (EF000008)45.0
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Height (EF000040)119.0
Marine / Shippingother
mounting positionany
operating voltage
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIRIUS
● during storage-50 ... +80 °C
Packaging Dimension52,50 x 133,00 x 106,50
Product DescriptionCircuit breaker size S0 for starter combination Rated current 20 A N-release 260 A Spring-type terminal Standard switching capacity
ambient temperature
operating frequency
operational current
product designationCircuit breaker
● at AC-3 maximum15 1/h
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productFor starter combinations
— solid or stranded2x (1 ... 10 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
product type designation3RV2
— at 230 V rated value5.5 kW
— at 400 V rated value7.5 kW
— at 500 V rated value11 kW
— at 690 V rated value15 kW
● at 240 V rated value100 kA
● at 400 V rated value25 kA
● at 480 V rated value20 A
● at 500 V rated value5 kA
● at 600 V rated value20 A
● at 690 V rated value2 kA
● for 3-phase AC motor
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
● ground fault detectionNo
Standard lead time ex-works70 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 3 mm
size of the circuit-breakerS0
size of the screwdriver tip3,0 x 0,5 mm
● for live parts at 400 V
● for live parts at 500 V
● for live parts at 690 V
● phase failure detectionNo
Package size unit of measureMM
UK Declaration of Conformity
— at 110/120 V rated value1.5 hp
— at 200/208 V rated value7.5 hp
— at 220/230 V rated value5 hp
— at 460/480 V rated value10 hp
● for main current circuitspring-loaded terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
● for single-phase AC motor
Device construction (EF008240)Built-in device fixed built-in technique
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value55 kA
● at AC at 500 V rated value10 kA
● at AC at 690 V rated value4 kA
Switch off technique (EF007007)Magnetic
operating frequency rated value50 ... 60 Hz
operational current rated value20 A
● at AC-3 rated value maximum690 V
● for grounded parts at 400 V
● for grounded parts at 500 V
● for grounded parts at 690 V
design of the short-circuit tripmagnetic
proportion of dangerous failures
● at AC in hot operating state10.5 W
● at AC-3 at 400 V rated value20 A
● of the main contacts typical100 000
● of auxiliary contacts typical100 000
Phase failure sensitive (EF007400)false
Rated operating voltage (EF001435)['690', '690']
Type of control element (EF006976)Turn button
With thermal protection (EF006233)-
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
yielded mechanical performance [hp]
● at AWG cables for main contacts2x (18 ... 8)
Degree of protection (IP) (EF005474)IP20
display version for switching statusHandle
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RV2321-4BC20
Rated permanent current Iu (EF001389)20.0
WEEE (2012/19/EU) Take-Back ObligationYes
● between main and auxiliary circuit400 V
reference code according to IEC 81346-2Q
number of poles for main current circuit3
product function short circuit protectionYes
● at AC in hot operating state per pole3.5 W
mechanical service life (switching cycles)
Overload release current setting (EF002336)['-', '-']
With integrated auxiliary switch (EF001387)false
full-load current (FLA) for 3-phase AC motor
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
shock resistance according to IEC 60068-2-2725g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 6 mm²)
power loss [W] for rated value of the current
● with low demand rate according to SN 3192050 %
Rated operation power at AC-3, 230 V (EF007025)5.5
Rated operation power at AC-3, 400 V (EF001364)7.5
electrical endurance (switching cycles) typical100 000
— finely stranded without core end processing2x (1 ... 6 mm²)
● with high demand rate according to SN 319205 000
With integrated under voltage release (EF001390)false
size of contactor can be combined company-specificS00, S0
Region Specific PriceGroup / Headquarter Price Group41E / 41E
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
breaking capacity maximum short-circuit current (Icu)
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Spring clamp connection
Adjustment range undelayed short-circuit release (EF007131)['260', '260']
arrangement of electrical connectors for main current circuitTop and bottom
breaking capacity operating short-circuit current (Ics) at AC
insulation voltage with degree of pollution 3 at AC rated value690 V
response value current of instantaneous short-circuit trip unit260 A
Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049)55.0
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
product component removable terminal for auxiliary and control circuitNo
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
maximum permissible voltage for safe isolation in networks with grounded star point
design of the fuse link for IT network for short-circuit protection of the main circuit
General Product ApprovalConfirmationKCDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationotherRailwayVibration and ShockConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top