Key Specifications
:Confirmation
EAN:4011209909809
UPC:040892960877
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209909809
UPC040892960877
ETIM5
IDEA4
depth97 mm
width45 mm
UNSPSC14
eClass6
height97 mm
B10 value
Group CodeR711
trip classCLASS 10
— upwards50 mm
● at AC-3
Metal FactorLBP-----
● at 400 VgG 63 A
● at 500 VgG 50 A
● at 690 VgG 50 A
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5333
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
— downwards50 mm
Commodity Code85362090
Product familySIRIUS 3RV2 motor starter protectors
last modified:1/27/2022
Net Weight (kg)0,363 Kg
operating power
— at the side30 mm
● rated value690 V
Depth (EF000049)97.0
Width (EF000008)45.0
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Height (EF000040)97.0
Marine / Shippingother
Test CertificatesMarine / Shipping
mounting positionany
operating voltage
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIRIUS
● during storage-50 ... +80 °C
Packaging Dimension49,00 x 102,00 x 102,00
Product DescriptionCircuit breaker size S0 for motor protection, CLASS 10 A-release 17...22 A N-release 286 A screw terminal Switching capacity 30 kA at 600 V according to UL/CSA
ambient temperature
operating frequency
operational current
product designationCircuit breaker
● at AC-3 maximum15 1/h
● during operation-20 ... +60 °C
● during transport-50 ... +80 °C
design of the productFor motor protection
— solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalTest Certificates
Special Test Certificate
product type designation3RV2
temperature compensation-20 ... +60 °C
— at 230 V rated value5.5 kW
— at 400 V rated value11 kW
— at 500 V rated value11 kW
— at 690 V rated value18.5 kW
● at 480 V rated value22 A
● at 600 V rated value22 A
● at 690 V rated value2 kA
● for 3-phase AC motor
Export Control RegulationsAL : N / ECCN : N
Number of poles (EF001391)3
● ground fault detectionNo
Standard lead time ex-works70 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 5 to 6 mm
size of the circuit-breakerS0
size of the screwdriver tipPozidriv size 2
● for live parts at 690 V
● phase failure detectionYes
Package size unit of measureMM
— at 110/120 V rated value1.5 hp
— at 200/208 V rated value7.5 hp
— at 220/230 V rated value7.5 hp
— at 460/480 V rated value15 hp
— at 575/600 V rated value20 hp
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
● for single-phase AC motor
Device construction (EF008240)Built-in device fixed built-in technique
design of the overload releasethermal
● at AC at 690 V rated value4 kA
Switch off technique (EF007007)Magnetic
operating frequency rated value50 ... 60 Hz
operational current rated value22 A
● at AC-3 rated value maximum690 V
● for grounded parts at 690 V
design of the short-circuit tripmagnetic
proportion of dangerous failures
● at AC in hot operating state10.5 W
● at AC-3 at 400 V rated value22 A
● of the main contacts typical100 000
● of auxiliary contacts typical100 000
Phase failure sensitive (EF007400)true
Rated operating voltage (EF001435)['690', '690']
Type of control element (EF006976)Turn button
With thermal protection (EF006233)thermal
product extension auxiliary switchYes
relative humidity during operation10 ... 95 %
yielded mechanical performance [hp]
● at AWG cables for main contacts2x (16 ... 12), 2x (14 ... 8)
Degree of protection (IP) (EF005474)IP20
display version for switching statusHandle
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RV2023-4CA10
Rated permanent current Iu (EF001389)22.0
WEEE (2012/19/EU) Take-Back ObligationYes
● between main and auxiliary circuit400 V
reference code according to IEC 81346-2Q
number of poles for main current circuit3
product function short circuit protectionYes
● at AC in hot operating state per pole3.5 W
mechanical service life (switching cycles)
Overload release current setting (EF002336)['16', '22']
With integrated auxiliary switch (EF001387)false
design of the thread of the connection screw
full-load current (FLA) for 3-phase AC motor
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
shock resistance according to IEC 60068-2-2725g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
power loss [W] for rated value of the current
● with low demand rate according to SN 3192050 %
Rated operation power at AC-3, 230 V (EF007025)5.5
Rated operation power at AC-3, 400 V (EF001364)11.0
electrical endurance (switching cycles) typical100 000
● for main contacts with screw-type terminals2 ... 2.5 N·m
● with high demand rate according to SN 319205 000
With integrated under voltage release (EF001390)false
size of contactor can be combined company-specificS00, S0
Region Specific PriceGroup / Headquarter Price Group41E / 41E
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
breaking capacity maximum short-circuit current (Icu)
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
Adjustment range undelayed short-circuit release (EF007131)['286', '286']
arrangement of electrical connectors for main current circuitTop and bottom
breaking capacity operating short-circuit current (Ics) at AC
insulation voltage with degree of pollution 3 at AC rated value690 V
response value current of instantaneous short-circuit trip unit286 A
Rated short-circuit breaking capacity lcu at 400 V, AC (EF007049)55.0
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
product component removable terminal for auxiliary and control circuitNo
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable current response value current of the current-dependent overload release16 ... 22 A
maximum permissible voltage for safe isolation in networks with grounded star point
design of the fuse link for IT network for short-circuit protection of the main circuit
General Product ApprovalTest CertificatesConfirmationType Test Certificates/Test ReportTest CertificatesMarine / ShippingSpecial Test CertificateMarine / ShippingotherRailwayConfirmationConfirmationVibration and ShockGeneral Product Approval

Product Description

SWITCH AUT. TAM. S0, P/ PROTEC. ENGINES, CLASS 10, DISP. A 17...22A, DISP. N 286A, SCREW TERMINALS, STANDARD CUTTING POWER,. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide