| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209893061 |
| UPC | 040892567502 |
| ETIM | 4 |
| IDEA | 4 |
| Depth | 97 mm |
| Width | 45 mm |
| Height | 97 mm |
| UNSPSC | 14 |
| eClass | 6 |
| B10 value | |
| Group Code | R711 |
| Trip class | CLASS 10 |
| Price Group | 41E |
| — upwards | 30 mm |
| ● at AC-3 | |
| ● maximum | 2 000 m |
| ● typical | 100 000 |
| Metal Factor | LBP----- |
| — forwards | 0 mm |
| ● at 400 V | gG 63 A |
| ● at 500 V | gG 50 A |
| ● at 690 V | gG 40 A |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 |
| Product Group | 5333 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| — Backwards | 0 mm |
| — downwards | 30 mm |
| Commodity Code | 85362090 |
| Product family | SIRIUS 3RV2 motor starter protectors |
| last modified: | 08/13/2020 |
| Display version | |
| Net Weight (kg) | 0,365 Kg |
| Operating power | |
| — at the side | 9 mm |
| ● rated value | 690 V |
| Product function | |
| Required spacing | |
| Shock resistance | |
| Country of origin | Germany |
| Marine / Shipping | other |
| Operating current | |
| Operating voltage | |
| Product extension | |
| Test Certificates | Marine / Shipping |
| Tightening torque | |
| Failure rate [FIT] | |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| ● during storage | -50 ... +80 °C |
| Ambient temperature | |
| Operating frequency | |
| Packaging Dimension | 49,00 x 102,00 x 102,00 |
| Product Description | Circuit breaker size S0 for system protection without phase failure protection A-release 10...16 A N-release 208 A screw terminal Standard switching capacity |
| Product designation | Circuit breaker |
| ● at AC-3 maximum | 15 1/h |
| ● Auxiliary switch | Yes |
| ● during operation | -20 ... +60 °C |
| ● during transport | -50 ... +80 °C |
| Design of the product | for system protection |
| Number of CO contacts | |
| ● for main contacts | |
| ● mounting position | any |
| Response value current | |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | Declaration of Conformity |
| Product type designation | 3RV2 |
| Rated voltage (EF003977) | - |
| Special Test Certificate | |
| Temperature compensation | -20 ... +60 °C |
| — at 230 V rated value | 4 000 W |
| — at 400 V rated value | 16 A |
| — at 500 V rated value | 7 500 W |
| — at 690 V rated value | 11 000 W |
| ● at 240 V rated value | 100 kA |
| ● at 400 V rated value | 25 kA |
| ● at 480 V rated value | 16 A |
| ● at 500 V rated value | 5 kA |
| ● at 600 V rated value | 16 A |
| ● at 690 V rated value | 2 kA |
| ● for switching status | Handle |
| Export Control Regulations | AL : N / ECCN : N |
| Number of poles (EF001391) | 3 |
| ● Ground fault detection | No |
| ● acc. to IEC 60068-2-27 | 25g / 11 ms |
| ● for auxiliary contacts | 0 |
| Design of screwdriver shaft | Diameter 5 to 6 mm |
| Size of the circuit-breaker | S0 |
| Size of the screwdriver tip | Pozidriv 2 |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| ● Phase failure detection | No |
| ● for live parts at 400 V | |
| ● for live parts at 500 V | |
| ● for live parts at 690 V | |
| Package size unit of measure | MM |
| — at 110/120 V rated value | 1 hp |
| — at 200/208 V rated value | 3 hp |
| — at 220/230 V rated value | 5 hp |
| — at 460/480 V rated value | 10 hp |
| — single or multi-stranded | 2x (1 ... 2,5 mm²), 2x (2,5 ... 10 mm²) |
| ● for three-phase AC motor | |
| Operating current rated value | 16 A |
| ● for single-phase AC motor | |
| Design of the overload release | thermal |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Product Dimensions (W x L x H) | Not available |
| ● at AC at 240 V rated value | 100 kA |
| ● at AC at 400 V rated value | 55 kA |
| ● at AC at 500 V rated value | 10 kA |
| ● at AC at 690 V rated value | 4 kA |
| Motor drive optional (EF007386) | false |
| Operating frequency rated value | 50 ... 60 Hz |
| ● at AC-3 rated value maximum | 690 V |
| ● for grounded parts at 400 V | |
| ● for grounded parts at 500 V | |
| ● for grounded parts at 690 V | |
| Design of the short-circuit trip | magnetic |
| Proportion of dangerous failures | |
| ● at AC in hot operating state | 9.25 W |
| ● of the main contacts typical | 100 000 |
| Motor drive integrated (EF006697) | false |
| ● of auxiliary contacts typical | 500 |
| Relative humidity during operation | 10 ... 95 % |
| Type of control element (EF006976) | Toggle |
| Yielded mechanical performance [hp] | |
| Degree of protection (IP) (EF005474) | IP20 |
| Surge voltage resistance rated value | 6 kV |
| ● protection class IP on the front | IP20 |
| Article Number (Market Facing Number) | 3RV2021-4AA10-0DA0 |
| Rated permanent current Iu (EF001389) | 16.0 |
| Reference code acc. to DIN EN 81346-2 | Q |
| With under voltage release (EF007518) | false |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With switched-off indicator (EF007006) | false |
| Electrical endurance (switching cycles) | |
| ● Protection class IP of the terminal | IP20 |
| ● at AWG conductors for main contacts | 2x (16 ... 12), 2x (14 ... 8) |
| Number of poles for main current circuit | 3 |
| Product function Short circuit protection | Yes |
| ● at AC in hot operating state per pole | 3.1 W |
| ● with low demand rate acc. to SN 31920 | 50 % |
| Mechanical service life (switching cycles) | |
| ● with high demand rate acc. to SN 31920 | 5 000 |
| Overload release current setting (EF002336) | ['10', '16'] |
| Design of the thread of the connection screw | |
| Integrated earth fault protection (EF007296) | false |
| Number of NC contacts for auxiliary contacts | 0 |
| Number of NO contacts for auxiliary contacts | 0 |
| Type of connectable conductor cross-sections | |
| — finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² |
| ● of instantaneous short-circuit trip unit | 208 A |
| Power loss [W] for rated value of the current | |
| maximum permissible voltage for safe isolation | |
| Complete device with protection unit (EF008906) | - |
| Installation altitude at height above sea level | |
| ● for main contacts with screw-type terminals | 2 ... 2.5 N·m |
| Full-load current (FLA) for three-phase AC motor | |
| Size of contactor can be combined company-specific | S00, S0 |
| DIN rail (top hat rail) mounting optional (EF008904) | - |
| Maximum short-circuit current breaking capacity (Icu) | |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | FALSE |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| ● removable terminal for auxiliary and control circuit | No |
| Position of connection for main current circuit (EF006671) | Other |
| ● Type of electrical connection for main current circuit | screw-type terminals |
| Adjustment range undelayed short-circuit release (EF007131) | ['208', '208'] |
| Arrangement of electrical connectors for main current circuit | Top and bottom |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| Operational short-circuit current breaking capacity (Ics) at AC | |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| T1 value for proof test interval or service life acc. to IEC 61508 | 10 y |
| Adjustment range short-term delayed short-circuit release (EF007129) | ['-', '-'] |
| Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) | 55.0 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2009 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| adjustable pick-up value current of the current-dependent overload release | 10 ... 16 A |
| ● in networks with grounded star point between main and auxiliary circuit | 400 V |
| Design of the fuse link for IT network for short-circuit protection of the main circuit | |
| General Product ApprovalDeclaration of ConformityTest CertificatesKCMiscellaneousType Test Certificates/Test ReportTest CertificatesMarine / ShippingSpecial Test CertificateMarine / ShippingotherRailwayConfirmationVibration and ShockConfirmation | General Product Approval |
Technical specifications and performance data