Key Specifications
Depth:149 mm
Width:55 mm
Height:140 mm
— solid:2x (0.75 ... 16 mm²)
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Depth149 mm
Width55 mm
Height140 mm
— solid2x (0.75 ... 16 mm²)
Trip classClass 20
● at AC-3
— stranded2x (0.75 ... 25 mm²), 1x (0.75 … 35 mm²)
Mounting typescrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
— Backwards0 mm
Operating power
— at the side0 mm
● rated value690 V
Product function
Required spacing
Shock resistance25g / 11 ms
● on the frontIP20
Mounting positionany
Operating current
Operating voltage
Product extension
product brand nameSIRIUS
● during storage-50 ... +80 °C
Ambient temperature
Operating frequency
Product designationcircuit breaker
Protection class IP
● at AC-3 maximum15 1/h
● Auxiliary switchYes
● during operation-50 ... +60 °C
● during transport-50 ... +80 °C
Design of the productfor motor protection
Number of CO contacts
● for main contacts
— at 400 V rated value40 A
● for auxiliary contacts0
Power loss [W] total typical20 W
● for main current circuitscrew-type terminals with box terminals
Type of electrical connection
● at AC at 240 V rated value100 kA
● at AC at 400 V rated value50 kA
● at AC at 500 V rated value10 kA
● at AC at 690 V rated value4 kA
● with side-by-side mounting
● at AC-3 rated value maximum690 V
● of the main contacts typical500
Surge voltage resistance rated value6 000 V
● at AWG conductors for main contacts2x (18 ... 2), 1x (18 ... 2)
Mechanical service life (switching cycles)
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.75 ... 16 mm²), 0.75 ... 25 mm²
● for auxiliary and control current circuitscrew-type terminals
Maximum short-circuit current breaking capacity (Icu)
Installation altitude at height above sea level maximum2 000 m
● removable terminal for auxiliary and control circuitNo
Design of the overcurrent release and short-circuit releasethermomagnetic
Arrangement of electrical connectors for main current circuitfront side
Adjustable pick-up value current of the current-dependent overload release28 ... 40 A