Key Specifications
:Value
EAN:4011209781665
UPC:662643920444
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209781665
UPC662643920444
ETIM4
IDEA4
Depth70 mm
Width45 mm
Height76 mm
UNSPSC14
eClass6
● Notefor contactor disconnection
Group CodeR711
Trip classCLASS 10
Price Group41F
● maximum2 000 m
Metal FactorL-O-----
Mounting typeContactor mounting
Product Group5346
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
Product family3RU2 for standard applications
last modified:08/19/2020
Display version
Net Weight (kg)0,159 Kg
● rated value690 V
Product function
Shock resistance
Country of originGermany
Marine / Shippingother
Operating voltage
Tightening torque
Failure rate [FIT]
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-55 ... +80 °C
Ambient temperature
Packaging Dimension49,00 x 102,00 x 84,00
Product DescriptionOverload relay 5.5...8.0 A Thermal For motor protection Size S00, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
Product designationthermal overload relay
Vibration and Shock
● during operation-40 ... +70 °C
● during transport-55 ... +80 °C
Number of CO contacts
● for main contacts
● mounting positionany
Size of overload relayS00
Design of the fuse link
Operating power at AC-3
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalFor use in hazardous locations
Product type designation3RU2
Release class (EF006668)CLASS 10
Temperature compensation-40 ... +60 °C
● at 400 V rated value3 kW
● at 480 V rated value8 A
● at 500 V rated value4 kW
● at 600 V rated value8 A
● at 690 V rated value5.5 kW
● for switching statusSlide switch
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
MTTF with high demand rate2 280 y
Mounting method (EF000003)-
● acc. to IEC 60068-2-278g / 11 ms
● for auxiliary contacts0
Design of screwdriver shaftDiameter 5 ... 6 mm
Size of the screwdriver tipPozidriv PZ 2
Standard lead time ex-works1 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
— single or multi-stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
Operating current rated value8 A
Design of the auxiliary switchintegrated
Design of the overload releasethermal
Product Dimensions (W x L x H)Not available
Operating frequency rated value50 ... 60 Hz
Reset function input (EF011940)-
● at AC-3 rated value maximum690 V
● at AC in hot operating state6.6 W
Relative humidity during operation10 ... 95 %
Adjustable current range (EF008211)['5.5', '8']
Reset function automatic (EF011941)-
Surge voltage resistance rated value6 kV
● protection class IP on the frontIP20
Article Number (Market Facing Number)3RU2116-1HB0
Reference code acc. to DIN EN 81346-2F
Reset function push-button (EF011942)-
WEEE (2012/19/EU) Take-Back ObligationYes
● Protection class IP of the terminalIP20
● at AWG conductors for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Number of poles for main current circuit3
● at AC in hot operating state per pole2.2 W
● of the auxiliary and control contactsM3
● with low demand rate acc. to SN 3192050 FIT
Max. rated operation voltage Ue (EF007357)690
Design of the thread of the connection screw
Number of NC contacts for auxiliary contacts1
Number of NO contacts for auxiliary contacts1
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
Power loss [W] for rated value of the current
maximum permissible voltage for safe isolation
Installation altitude at height above sea level
● for main contacts with screw-type terminals0.8 ... 1.2 N·m
Full-load current (FLA) for three-phase AC motor
Size of contactor can be combined company-specificS00
Contact rating of auxiliary contacts according to ULB600 / R300
● for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
Type of electrical connection of main circuit (EF006819)Screw connection
● removable terminal for auxiliary and control circuitNo
Type of protection according to ATEX directive 2014/34/EUEx II (2) GD
● Type of electrical connection for main current circuitscrew-type terminals
● Operating current of auxiliary contacts at DC-13 at 60 V0.3 A
● operating current of auxiliary contacts at AC-15 at 24 V3 A
● operating current of auxiliary contacts at DC-13 at 24 V2 A
Arrangement of electrical connectors for main current circuitTop and bottom
● Operating current of auxiliary contacts at AC-15 at 110 V3 A
● Operating current of auxiliary contacts at AC-15 at 120 V3 A
● Operating current of auxiliary contacts at AC-15 at 125 V3 A
● Operating current of auxiliary contacts at AC-15 at 230 V2 A
● Operating current of auxiliary contacts at DC-13 at 110 V0.22 A
● Operating current of auxiliary contacts at DC-13 at 220 V0.11 A
● operating current of auxiliary contacts at AC-15 at 400 V1 A
● operating current of auxiliary contacts at DC-13 at 125 V0.22 A
Number of auxiliary contacts as change-over contact (EF003531)0
Insulation voltage with degree of pollution 3 at AC rated value690 V
Number of auxiliary contacts as normally open contact (EF001376)1
Certificate of suitability according to ATEX directive 2014/34/EUDMT 98 ATEX G 001
● for short-circuit protection of the auxiliary switch requiredfuse gG: 6 A, quick: 10 A
Number of auxiliary contacts as normally closed contact (EF001377)1
T1 value for proof test interval or service life acc. to IEC 6150820 y
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable pick-up value current of the current-dependent overload release5.5 ... 8 A
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
● in networks with grounded star point between main and auxiliary circuit440 V
● in networks with grounded star point between auxiliary and auxiliary circuit440 V
General Product ApprovalFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherConfirmationRailwayVibration and ShockGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top