Service time: Monday to Friday 9:00-18:00
3RT2646-1AB05 - 3RT2646-1AB05 SIEMENS Capacitor contactor, AC-6b 100 kVAr, / 400 V 2 NC, 24 V AC, 50 Hz 3-pole, Size S3 scre..
In Stock Hot Product

3RT2646-1AB05

3RT2646-1AB05 SIEMENS Capacitor contactor, AC-6b 100 kVAr, / 400 V 2 NC, 24 V AC, 50 Hz 3-pole, Size S3 scre..

$0.00USD
3941 in stock
Key Specifications
:Confirmation
EAN:4047621026381
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4047621026381
UPCNot available
ETIM5
IDEA4
depth152 mm
width80 mm
UNSPSC15
eClass6
height140 mm
— solid2x (10 ... 16 mm²)
● at AC6.8g / 5 ms, 4g / 10 ms
Group CodeR711
arcing time10 ... 20 ms
● at 24 V6 A
● at 60 V2 A
Date5/5/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLCO-----
— stranded2x (10 ... 70 mm²), 1x (10 ... 70 mm²)
● at 110 V1 A
● at 125 V0.9 A
● at 220 V0.3 A
● at 230 V6 A
● at 400 V3 A
● at 50 Hz0.8 ... 1.1
Product Group5370
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
closing delay
opening delay
● at 40 °C1x 70 mm²
● at 60 °C2x 50 mm²
Commodity Code85364900
Product familySIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
last modified:12/8/2021
● attachable1
Net Weight (kg)1,730 Kg
type of voltageAC
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
product function
required spacing
Country of originGermany
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
size of contactorS3
● 1 rated value50 Hz
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● of magnet coilScrew-type terminals
Packaging Dimension153,50 x 160,00 x 100,00
Product DescriptionCapacitor contactor, AC-6b 100 kVAr, / 400 V 2 NC, 24 V AC, 50 Hz 3-pole, Size S3 screw terminal
ambient temperature
product designationcapacitor contactors
● at 230 V maximum150 1/h
● at 240 V maximum150 1/h
● at 400 V maximum80 1/h
● at 480 V maximum53 1/h
● at 500 V maximum53 1/h
● at 600 V maximum32 1/h
● at 690 V maximum30 1/h
● during operation-25 ... +60 °C
Transport Information
— solid or stranded2x (10 ... 70 mm²), 1x (10 ... 70 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
General Product ApprovalEMC
product type designation3RT26
surge voltage resistance
● at 50 Hz rated value24 V
Declaration of ConformityTest Certificates
relative humidity minimum10 %
● instantaneous contact2
Export Control RegulationsAL : N / ECCN : N
● for auxiliary contacts
Standard lead time ex-works40 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
Package size unit of measureMM
control supply voltage at AC
operating frequency at AC-6b
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)06/26/2017
type of electrical connection
● of main circuit rated value8 kV
control supply voltage frequency
shock resistance with sine pulse
operating reactive power at AC-6b
product extension auxiliary switchYes
● for grounded parts at the side10 mm
● at AWG cables for main contacts2x (8 ... 3/0), 1x (6 ... 3/0)
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2646-1AB05
Voltage type for actuating (EF008242)AC
● for auxiliary and control circuitscrew-type terminals
WEEE (2012/19/EU) Take-Back ObligationYes
electrical endurance (switching cycles)120 000
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
contact reliability of auxiliary contacts0.00000001
mechanical service life (switching cycles)
● with side-by-side mounting at the side10 mm
apparent holding power of magnet coil at AC19 VA
apparent pick-up power of magnet coil at AC296 VA
Rated blind power at 400 V, 50 Hz (EF007044)100.0
number of NC contacts for auxiliary contacts2
number of NO contacts for auxiliary contacts0
type of connectable conductor cross-sections
— finely stranded with core end processing2x (10 ... 50 mm²)
type of voltage of the control supply voltageAC
● mirror contact according to IEC 60947-4-1No
Rated control supply voltage Us at DC (EF003980)['-', '-']
control version of the switch operating mechanismStandard A1 - A2
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
inductive power factor with closing power of the coil0.61
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
inductive power factor with the holding power of the coil0.38
operational current of auxiliary contacts at AC-12 maximum10 A
● of main circuit with degree of pollution 3 rated value1 000 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)3
Number of normally closed contacts as main contact (EF001375)0
● of the contactor with added auxiliary switch block typical3 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value690 V
Number of auxiliary contacts as normally open contact (EF001376)0
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
● at 230 V at 50/60 Hz at ambient temperature 60 °C rated value19 ... 57 kvar
● at 400 V at 50/60 Hz at ambient temperature 60 °C rated value33 ... 100 kvar
● at 500 V at 50/60 Hz at ambient temperature 60 °C rated value41 ... 125 kvar
● at 690 V at 50/60 Hz at ambient temperature 60 °C rated value57 ... 172 kvar
type of minimum connectable cross-section for main contacts at AC-6b
Compliance with the substance restrictions according to RoHS directiveSince: 26.06.2017
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
AWG number as coded connectable conductor cross section for main contacts8
operating range factor control supply voltage rated value of magnet coil at AC
operational current at AC-6b at 690 V at ambient temperature 60 °C rated value144 A
● for short-circuit protection of the main circuit with type of coordination 1 requiredgG: 250 A (690 V, 50 kA)
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
General Product ApprovalEMCConfirmationKCDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmationDangerous GoodTransport InformationGeneral Product Approval

Product Description

contactor, AC - 6 B, 100 kVAr /. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide