Service time: Monday to Friday 9:00-18:00
3RT2636-1NF35 - 3RT2636-1NF35 SIEMENS Capacitor contactor, AC-6b 50 kVAr, / 400 V 2 NC, 50-60 Hz AC / 83-155 V DC 3-pole, Si..
In Stock Hot Product

3RT2636-1NF35

3RT2636-1NF35 SIEMENS Capacitor contactor, AC-6b 50 kVAr, / 400 V 2 NC, 50-60 Hz AC / 83-155 V DC 3-pole, Si..

$0.00USD
4205 in stock
Key Specifications
:Confirmation
EAN:4011209953468
EMC:Declaration of Conformity
UPC:804766160646
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209953468
EMCDeclaration of Conformity
UPC804766160646
ETIM5
IDEA4
depth130 mm
width65 mm
UNSPSC15
eClass6
height114 mm
— solid2x (1 ... 16 mm²)
● at AC6.8g / 5 ms, 4g / 10 ms
● at DC6,8g / 5 ms, 4g / 10 ms
Group CodeR711
arcing time10 ... 20 ms
● at 24 V6 A
● at 60 V2 A
Metal FactorLBP-----
— stranded2x (10 ... 35 mm²), 1x (10 ... 50 mm²)
● at 110 V1 A
● at 125 V0.9 A
● at 220 V0.3 A
● at 230 V6 A
● at 400 V3 A
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
Date5/10/2022Subject to change without notice© Copyright Siemens 2022
Product Group5338
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
closing delay
opening delay
● at 40 °C1x 35 mm²
● at 60 °C1x 50 mm²
Commodity Code85364900
Product familySIRIUS 3RT26 contactors for capacitive loads (AC-6b), 3-pole
last modified:12/8/2021
● attachable1
Net Weight (kg)1,108 Kg
type of voltageAC/DC
● rated value83 ... 155 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
product function
required spacing
Country of originGermany
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
size of contactorS2
● 1 rated value50 Hz
● 2 rated value60 Hz
● initial value0.8
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● of magnet coilScrew-type terminals
Packaging Dimension82,00 x 122,50 x 142,00
Product DescriptionCapacitor contactor, AC-6b 50 kVAr, / 400 V 2 NC, 50-60 Hz AC / 83-155 V DC 3-pole, Size S2 screw terminal
ambient temperature
inrush current peak12 A
product designationcapacitor contactors
● at 230 V maximum100 1/h
● at 240 V maximum100 1/h
● at 400 V maximum100 1/h
● at 480 V maximum60 1/h
● at 500 V maximum55 1/h
● at 600 V maximum40 1/h
● at 690 V maximum30 1/h
● during operation-25 ... +60 °C
● full-scale value1.1
Transport Information
— solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
● for main contacts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
product type designation3RT26
surge voltage resistance
● at 50 Hz rated value83 ... 155 V
● at 60 Hz rated value83 ... 155 V
locked-rotor current peak3.1 A
relative humidity minimum10 %
● instantaneous contact2
Export Control RegulationsAL : N / ECCN : N
holding current mean value22 mA
● for auxiliary contacts
Standard lead time ex-works50 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
Package size unit of measureMM
control supply voltage at AC
control supply voltage at DC
operating frequency at AC-6b
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)05/01/2014
type of electrical connection
duration of inrush current peak20 µs
locked-rotor current mean value1.3 A
● of main circuit rated value6 kV
control supply voltage frequency
duration of locked-rotor current230 ms
shock resistance with sine pulse
operating reactive power at AC-6b
closing power of magnet coil at DC70 W
holding power of magnet coil at DC1.5 W
product extension auxiliary switchYes
● for grounded parts at the side10 mm
● at AWG cables for main contacts2x (18 ... 2), 1x (18 ... 0)
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2636-1NF35
Voltage type for actuating (EF008242)AC/DC
● for auxiliary and control circuitscrew-type terminals
WEEE (2012/19/EU) Take-Back ObligationYes
electrical endurance (switching cycles)200 000
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
contact reliability of auxiliary contacts0.00000001
mechanical service life (switching cycles)
● with side-by-side mounting at the side10 mm
apparent holding power of magnet coil at AC2.5 VA
apparent pick-up power of magnet coil at AC110 VA
Rated blind power at 400 V, 50 Hz (EF007044)50.0
number of NC contacts for auxiliary contacts2
number of NO contacts for auxiliary contacts0
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
type of voltage of the control supply voltageAC/DC
● mirror contact according to IEC 60947-4-1No
Rated control supply voltage Us at DC (EF003980)['83', '155']
control version of the switch operating mechanismStandard A1 - A2
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Rated control supply voltage Us at AC 50HZ (EF003978)['83.0', '155.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['83.0', '155.0']
inductive power factor with closing power of the coil0.95
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
inductive power factor with the holding power of the coil0.95
operational current of auxiliary contacts at AC-12 maximum10 A
● of main circuit with degree of pollution 3 rated value690 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)3
Number of normally closed contacts as main contact (EF001375)0
● of the contactor with added auxiliary switch block typical3 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value690 V
Number of auxiliary contacts as normally open contact (EF001376)0
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
● at 230 V at 50/60 Hz at ambient temperature 60 °C rated value10 ... 29 kvar
● at 400 V at 50/60 Hz at ambient temperature 60 °C rated value17 ... 50 kvar
● at 500 V at 50/60 Hz at ambient temperature 60 °C rated value21 ... 63 kvar
● at 690 V at 50/60 Hz at ambient temperature 60 °C rated value29 ... 86 kvar
type of minimum connectable cross-section for main contacts at AC-6b
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2014
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
AWG number as coded connectable conductor cross section for main contacts18 ... 0
operating range factor control supply voltage rated value of magnet coil at AC
operating range factor control supply voltage rated value of magnet coil at DC
operational current at AC-6b at 690 V at ambient temperature 60 °C rated value72.2 A
● for short-circuit protection of the main circuit with type of coordination 1 requiredgG: 160 A (690 V, 50 kA)
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
General Product ApprovalConfirmationKCEMCDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmationDangerous GoodTransport InformationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top