| Parameter | Value |
|---|---|
| Depth | 73 mm |
| Width | 45 mm |
| Height | 70 mm |
| B10 value | |
| — at DC | 7.3g / 5 ms, 4.7g / 10 ms |
| — solid | 2x (0.5 ... 4 mm²) |
| ● at AC | 10 000 1/h |
| ● at DC | 10 000 1/h |
| Arcing time | 10 ... 15 ms |
| — upwards | 0 mm |
| ● at AC-1 | |
| — forwards | 0 mm |
| Closing delay | |
| Mounting type | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
| Opening delay | |
| — Backwards | 0 mm |
| — downwards | 0 mm |
| Operating power | |
| — at the side | 0 mm |
| ● rated value | 690 V |
| Product function | |
| Required spacing | |
| Shock resistance | |
| ● on the front | IP20 |
| Mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| Operating current | |
| Product extension | |
| Size of contactor | S00 |
| Failure rate [FIT] | |
| Insulation voltage | |
| product brand name | SIRIUS |
| ● during storage | -55 ... +80 °C |
| ● for live parts | |
| Ambient temperature | |
| Degree of pollution | 3 |
| Operating frequency | |
| Product designation | 3RT2 contactor |
| Protection class IP | |
| ● at AC-1 maximum | 1 000 1/h |
| ● at AC-2 at AC-3 | |
| ● with sine pulse | |
| ● Auxiliary switch | Yes |
| ● during operation | -25 ... +60 °C |
| Number of NC contacts | |
| Number of NO contacts | |
| ● for main contacts | |
| ● for grounded parts | |
| Design of the fuse link | |
| — at 24 V rated value | 20 A |
| ● at 24 V rated value | 10 A |
| ● at 48 V rated value | 6 A |
| ● at 60 V rated value | 6 A |
| — at 110 V rated value | 2.1 A |
| — at 220 V rated value | 0.8 A |
| — at 230 V rated value | 7.5 kW |
| — at 400 V rated value | 13 kW |
| — at 440 V rated value | 0.6 A |
| ● at 110 V rated value | 3 A |
| ● at 125 V rated value | 2 A |
| ● at 220 V rated value | 1 A |
| ● at 230 V rated value | 10 A |
| ● at 400 V rated value | 3 A |
| ● at 600 V rated value | 0.15 A |
| ● of contactor typical | 30 000 000 |
| — instantaneous contact | 1 |
| ● Side-by-side mounting | Yes |
| Operating current at AC-15 | |
| Operating current at DC-12 | |
| Operating current at DC-13 | |
| ● at rectangular impulse | |
| ● for auxiliary contacts | |
| No-load switching frequency | |
| Control supply voltage at DC | |
| — at 110/120 V rated value | 0.5 hp |
| — single or multi-stranded | 2x (0,5 ... 4 mm²) |
| ● at AC-2 at AC-3 at 400 V | |
| ● for main current circuit | spring-loaded terminals |
| Type of electrical connection | |
| ● at 1 current path at DC-1 | |
| ● for single-phase AC motor | |
| Design of the surge suppressor | with diode assemblies |
| — per NC contact rated value | 9 A |
| — per NO contact rated value | 12 A |
| ● with side-by-side mounting | |
| Proportion of dangerous failures | |
| ● at 40 °C minimum permissible | 4 mm² |
| ● at 60 °C minimum permissible | 2.5 mm² |
| Closing power of magnet coil at DC | 4 W |
| Holding power of magnet coil at DC | 1.6 W |
| Operating current at AC-12 maximum | 10 A |
| Yielded mechanical performance [hp] | |
| Surge voltage resistance rated value | 6 kV |
| ● at 1 current path at DC-3 at DC-5 | |
| ● function module for communication | No |
| — at 24 V per NC contact rated value | 20 A |
| — at 24 V per NO contact rated value | 20 A |
| — with type of assignment 2 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 20 A |
| ● at AC at 230 V maximum permissible | 0.004 A |
| Number of NC contacts for main contacts | 2 |
| Number of NO contacts for main contacts | 2 |
| — at 110 V per NC contact rated value | 0.075 A |
| — at 110 V per NO contact rated value | 0.15 A |
| — at 220 V per NC contact rated value | 0.375 A |
| — at 220 V per NO contact rated value | 0.75 A |
| — at 230 V per NC contact rated value | 2.2 kW |
| — at 230 V per NO contact rated value | 3 kW |
| — at 400 V per NC contact rated value | 4 kW |
| — at 400 V per NO contact rated value | 5.5 kW |
| ● at AWG conductors for main contacts | 2x (20 ... 12) |
| — with type of coordination 1 required | gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A |
| ● Mirror contact acc. to IEC 60947-4-1 | Yes; with 3RH29 |
| Contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| ● with low demand rate acc. to SN 31920 | 40 % |
| Mechanical service life (switching cycles) | |
| ● with 2 current paths in series at DC-1 | |
| ● with high demand rate acc. to SN 31920 | 1 000 000 |
| Type of connectable conductor cross-sections | |
| — finely stranded with core end processing | 2x (0.5 ... 2.5 mm²) |
| ● at AWG conductors for auxiliary contacts | 2x (20 ... 12) |
| Type of voltage of the control supply voltage | DC |
| ● for auxiliary and control current circuit | spring-loaded terminals |
| maximum permissible voltage for safe isolation | |
| — finely stranded without core end processing | 2x (0.5 ... 2.5 mm²) |
| ● with 2 current paths in series at DC-3 at DC-5 | |
| Contact rating of auxiliary contacts according to UL | A600 / Q600 |
| ● for short-circuit protection of the main circuit | |
| ● between coil and main contacts acc. to EN 60947-1 | 400 V |
| ● positively driven operation acc. to IEC 60947-5-1 | No |
| Installation altitude at height above sea level maximum | 2 000 m |
| — up to 690 V at ambient temperature 40 °C rated value | 22 A |
| — up to 690 V at ambient temperature 60 °C rated value | 20 A |
| Connectable conductor cross-section in main circuit at AC-1 | |
| ● of the contactor with added auxiliary switch block typical | 10 000 000 |
| Residual current of the electronics for control with signal <0> | |
| ● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| T1 value for proof test interval or service life acc. to IEC 61508 | 20 y |
| Operating range factor control supply voltage rated value of magnet coil at DC | 0.85 ... 1.85 |
| ● of the contactor with added electronics-compatible auxiliary switch block typical | 5 000 000 |
| Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor | 1.2 W |