Service time: Monday to Friday 9:00-18:00
3RT2448-6KB40-0KS0 - 3RT2448-6KB40-0KS0 SIEMENS Contactor, AC-1, 160 A/690 V/40 °C, S3, 3-pole, 24 V DC, with varistor, 1 NO+1 NC..
In Stock Hot Product

3RT2448-6KB40-0KS0

3RT2448-6KB40-0KS0 SIEMENS Contactor, AC-1, 160 A/690 V/40 °C, S3, 3-pole, 24 V DC, with varistor, 1 NO+1 NC..

$0.00USD
3158 in stock
Key Specifications
:
EAN:4047621068305
EMC:Functional Safety/Safety of Machinery
UPC:195125050068
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621068305
EMCFunctional Safety/Safety of Machinery
UPC195125050068
ETIM5
IDEA4
depth152 mm
otherRailway
width70 mm
UNSPSC15
eClass6
height140 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at DC6.7 g / 5 ms, 4.0 g / 10 ms
Group CodeR711
arcing time10 ... 20 ms
— upwards10 mm
● at AC-1
● at AC-3
ConfirmationVibration and Shock
Metal FactorLEO-----
— forwards20 mm
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5370
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
last modified:3/15/2022
● attachable2
Net Weight (kg)1,674 Kg
number of holes1
type of voltageDC
— at the side0 mm
● rated value24 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
diameter of holes6.6 mm
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
product extension
size of contactorS3
● initial value0.8
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Packaging Dimension80,00 x 160,00 x 165,00
Product Descriptioncontactor, AC-1, 160 A/690 V/40 °C, S3, 3-pole, 24 V DC, with varistor, ring cable lug connection/ screw terminal
ambient temperature
inrush current peak2.7 A
operational current
product designationContactor
● auxiliary switchYes
● during operation-25 ... +60 °C
● full-scale value1.2
— solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● solid or stranded0.5 ... 2.5 mm²
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
width of connection bar11 mm
● at 24 V rated value10 A
● at 48 V rated value2 A
● at 60 V rated value2 A
product type designation3RT24
surge voltage resistance
— at 400 V rated value44 A
— at 690 V rated value44 A
● at 110 V rated value1 A
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
● at 230 V rated value6 A
● at 400 V rated value3 A
● at 500 V rated value2 A
● at 600 V rated value0.1 A
● at 690 V rated value1 A
● of contactor typical10 000 000
locked-rotor current peak2.1 A
relative humidity minimum10 %
● instantaneous contact1
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : EAR99
holding current mean value40 mA
● for auxiliary contacts
Standard lead time ex-works40 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
thickness of connection bar2.5 mm
Package size unit of measureMM
control supply voltage at DC
operational current at AC-15
operational current at DC-13
● for main current circuitRing cable lug connection
Substance Prohibitance (Date)03/15/2019
type of electrical connection
design of the surge suppressorwith varistor
● with side-by-side mounting
duration of inrush current peak50 µs
locked-rotor current mean value0.9 A
● of main circuit rated value8 kV
duration of locked-rotor current150 ms
proportion of dangerous failures
shock resistance with sine pulse
● at AC in hot operating state38.4 W
closing power of magnet coil at DC76 W
holding power of magnet coil at DC2.7 W
operating frequency at AC-1 maximum650 1/h
operational current at AC-12 maximum10 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2448-6KB40-0KS0
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgR: 250 A (690 V, 100 kA)
● without load current share typical2.7 W
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit3
type of voltage for main current circuitAC
— with type of coordination 1 requiredgG: 250 A (690 V,100 kA)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
product function short circuit protectionNo
● at AC in hot operating state per pole12.8 W
mechanical service life (switching cycles)
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm²
power loss [W] for rated value of the current
type of voltage of the control supply voltageDC
● mirror contact according to IEC 60947-4-1Yes
● with low demand rate according to SN 3192040 %
● with high demand rate according to SN 3192073 %
control version of the switch operating mechanismStandard A1 - A2
Region Specific PriceGroup / Headquarter Price Group41B / 41B
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
● for short-circuit protection of the main circuit
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
— up to 690 V at ambient temperature 40 °C rated value160 A
— up to 690 V at ambient temperature 55 °C rated value140 A
— up to 690 V at ambient temperature 60 °C rated value140 A
connectable conductor cross-section for auxiliary contacts
— up to 1000 V at ambient temperature 40 °C rated value80 A
— up to 1000 V at ambient temperature 60 °C rated value80 A
● of main circuit with degree of pollution 3 rated value1 000 V
● positively driven operation according to IEC 60947-5-1No
● of the contactor with added auxiliary switch block typical10 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value690 V
minimum cross-section in main circuit at maximum AC-1 rated value70 mm²
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Compliance with the substance restrictions according to RoHS directiveSince: 15.03.2019
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at DC
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
design of the miniature circuit breaker for short-circuit protection of the auxiliary switch requiredgG: 10 A (230 V, 400 A)
General Product ApprovalConfirmationKCEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesType Examination CertificateUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherRailwayConfirmationVibration and ShockGeneral Product Approval

Product Description

Contactor, AC-1:160 A 24 V DC, 3 poles, 3S, size S3 connection for bar, 1 NA+1 NC, integrated varistor, see. Custom: No Auxiliary Switch Integration, Only Usable with 3RH2911-2XF22-0KS1 Auxiliary Swit
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top