Service time: Monday to Friday 9:00-18:00
3RT2337-1NB30 - 3RT2337-1NB30 SIEMENS Contactor, 4 NO, AC-1: 110 A 20 ... 33 V AC / DC, varistor, 4-pole, 4 NO, Size S2, Scr..
In Stock Hot Product

3RT2337-1NB30

3RT2337-1NB30 SIEMENS Contactor, 4 NO, AC-1: 110 A 20 ... 33 V AC / DC, varistor, 4-pole, 4 NO, Size S2, Scr..

$0.00USD
4106 in stock
Key Specifications
:
EAN:4011209942943
EMC:Functional Safety/Safety of Machinery
UPC:887621918842
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209942943
EMCFunctional Safety/Safety of Machinery
UPC887621918842
ETIM5
IDEA4
depth130 mm
width75 mm
UNSPSC15
eClass6
height114 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AC7.7g / 5 ms, 4.5g / 10 ms
● at DC7.7g / 5 ms, 4.5g / 10 ms
Group CodeR711
arcing time10 ... 20 ms
— upwards10 mm
● at AC-1
● at AC-3
Date5/4/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLDP-----
— forwards10 mm
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
Product Group5338
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT.3 contactors, 4-pole, up to 525 A
last modified:3/18/2022
● attachable2
Net Weight (kg)1,279 Kg
type of voltageAC/DC
— at the side0 mm
● rated value20 ... 33 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Marine / Shippingother
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
product extension
size of contactorS2
● initial value0.8
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Packaging Dimension82,00 x 122,50 x 142,00
Product DescriptionContactor, AC-1, 110 A/400 V/40 °C, S2, 4-pole, 20-33 V AC/DC, with varistor, 1 NO+1 NC, screw terminal
ambient temperature
inrush current peak3 A
operational current
product designationContactor
● auxiliary switchYes
● during operation-40 ... +70 °C
● full-scale value1.1
— solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
● for main contacts
● solid or stranded1 ... 50 mm²
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
product type designation3RT23
surge voltage resistance
— at 400 V rated value38 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 230 V rated value10 A
● at 400 V rated value3 A
● at 50 Hz rated value20 ... 33 V
● at 500 V rated value2 A
● at 60 Hz rated value20 ... 33 V
● at 600 V rated value0.15 A
● at 690 V rated value1 A
● of contactor typical10 000 000
locked-rotor current peak2.6 A
relative humidity minimum10 %
● instantaneous contact1
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
holding current mean value40 mA
● for auxiliary contacts
Standard lead time ex-works1 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
Package size unit of measureMM
control supply voltage at AC
control supply voltage at DC
operational current at AC-15
operational current at DC-12
operational current at DC-13
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2014
type of electrical connection
design of the surge suppressorwith varistor
● with side-by-side mounting
duration of inrush current peak50 µs
locked-rotor current mean value1 A
● of main circuit rated value6 kV
duration of locked-rotor current230 ms
shock resistance with sine pulse
● at AC in hot operating state38.8 W
closing power of magnet coil at DC23 W
holding power of magnet coil at DC1 W
product function bus communicationNo
operating frequency at AC-1 maximum700 1/h
● at AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
operational current at AC-12 maximum10 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2337-1NB30
Rated operation power NEMA (EF011960)-
Voltage type for actuating (EF008242)AC/DC
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgR: 80 A (690 V, 100 kA)
● without load current share typical1 W
number of NO contacts for main contacts4
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit4
— with type of coordination 1 requiredgG: 160 A (690 V, 100 kA)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
product function short circuit protectionNo
● at AC in hot operating state per pole9.7 W
mechanical service life (switching cycles)
apparent holding power of magnet coil at AC
apparent pick-up power of magnet coil at AC
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
● finely stranded with core end processing1 ... 35 mm²
power loss [W] for rated value of the current
type of voltage of the control supply voltageAC/DC
● mirror contact according to IEC 60947-4-1Yes
Rated operation power at AC-3, 400 V (EF001364)-
Rated operation power at AC-4, 400 V (EF008496)-
● finely stranded without core end processing0.5 ... 2.5 mm²
Rated control supply voltage Us at DC (EF003980)['20', '33']
control version of the switch operating mechanismStandard A1 - A2
Rated operation current Ie at AC-1, 400 V (EF001393)110
Rated operation current Ie at AC-3, 400 V (EF001392)38
Rated operation current Ie at AC-4, 400 V (EF008495)-
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / P600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for short-circuit protection of the main circuit
● limited to 1 s switching at zero current maximumUse minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximumUse minimum cross-section acc. to AC-1 rated value
Rated control supply voltage Us at AC 50HZ (EF003978)['20.0', '33.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['20.0', '33.0']
connectable conductor cross-section for main contacts
● limited to 10 s switching at zero current maximumUse minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximumUse minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximumUse minimum cross-section acc. to AC-1 rated value
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
— up to 690 V at ambient temperature 40 °C rated value110 A
— up to 690 V at ambient temperature 60 °C rated value95 A
connectable conductor cross-section for auxiliary contacts
● of main circuit with degree of pollution 3 rated value690 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)4
Number of normally closed contacts as main contact (EF001375)-
● at AC-1 at 400 V at ambient temperature 40 °C rated value110 A
● of the contactor with added auxiliary switch block typical10 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Number of auxiliary contacts as normally open contact (EF001376)1
minimum cross-section in main circuit at maximum AC-1 rated value35 mm²
short-time withstand current in cold operating state up to 40 °C
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)1
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2014
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at AC
operating range factor control supply voltage rated value of magnet coil at DC
● of the auxiliary and control circuit with degree of pollution 3 rated value690 V
design of the miniature circuit breaker for short-circuit protection of the auxiliary switch requiredgG: 10 A (230 V, 400 A)
General Product ApprovalConfirmationKCEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesType Examination CertificateUK Declaration of ConformityType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingMarine / ShippingotherRailwayDangerous GoodConfirmationVibration and ShockTransport InformationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top