Key Specifications
:
EAN:4047621048000
EMC:Functional Safety/Safety of Machinery
UPC:Not available
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621048000
EMCFunctional Safety/Safety of Machinery
UPCNot available
ETIM5
IDEA4
depth73 mm
width45 mm
UNSPSC15
eClass6
height70 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
● at DC6,7g / 5 ms, 4,2g / 10 ms
Group CodeR711
arcing time10 ... 15 ms
— upwards10 mm
● at AC-1
● at AC-3
Date5/2/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLDP-----
— forwards10 mm
● at AC-3e
Product Group5330
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT contactors with extended application range, 3-pole
last modified:2/1/2022
Net Weight (kg)0,304 Kg
operating power
type of voltageDC
— at the side0 mm
● rated value72 ... 125 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
product function
required spacing
Country of originGermany
Marine / Shippingother
mounting positionhanging, on horizontal mounting surface
operating voltage
product extension
size of contactorS00
● initial value0.7
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilSpring-type terminals
Packaging Dimension50,00 x 81,00 x 73,00
Product DescriptionContactor for railway, AC-3, 7.5 kW 400 V, 1 NC,DC 72-125V,0.7-1.25*US, with integrated varistor Size S00, Spring-type terminal suitable for PLC outputs
ambient temperature
inrush current peak1.1 A
operating frequency
operational current
product designationContactor
● at AC-4 maximum250 1/h
● auxiliary switchYes
● during operation-40 ... +70 °C
● full-scale value1.25
design of the productWith extended operating range
— solid or stranded2x (0,5 ... 4 mm²)
● for main contacts
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
product type designation3RT2
surge voltage resistance
— at 230 V rated value4 kW
— at 400 V rated value16 A
— at 500 V rated value12.4 A
— at 690 V rated value8.9 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 230 V rated value10 A
● at 400 V rated value5.5 A
● at 480 V rated value14 A
● at 500 V rated value2 A
● at 600 V rated value0.15 A
● at 690 V rated value4.4 A
● for 3-phase AC motor
● of contactor typical30 000 000
locked-rotor current peak0.04 A
relative humidity minimum10 %
● instantaneous contact1
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
holding current mean value7 mA
● for auxiliary contacts
Standard lead time ex-works80 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
Package size unit of measureMM
control supply voltage at DC
operational current at AC-15
operational current at DC-12
operational current at DC-13
— at 110/120 V rated value1 hp
— at 200/208 V rated value3 hp
— at 220/230 V rated value5 hp
— at 460/480 V rated value10 hp
— at 575/600 V rated value10 hp
● at AC-2 at AC-3e maximum750 1/h
● for main current circuitspring-loaded terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
● for single-phase AC motor
design of the surge suppressorwith varistor
● at maximum Ith rated value4 mm²
● with side-by-side mounting
duration of inrush current peak50 µs
locked-rotor current mean value0.04 A
● at AC-3 rated value maximum690 V
● at maximum AC-1 rated value4 mm²
● of main circuit rated value6 kV
duration of locked-rotor current250 ms
proportion of dangerous failures
shock resistance with sine pulse
● at AC in hot operating state6.6 W
● at AC-2 at 400 V rated value16 A
● at AC-3e rated value maximum690 V
● at AC-4 at 400 V rated value11.5 A
thermal current (Ith) up to 690 V
closing power of magnet coil at DC4.5 W
holding power of magnet coil at DC0.75 W
product function bus communicationNo
yielded mechanical performance [hp]
● at AWG cables for main contacts2x (20 ... 12)
operational current at AC-12 maximum10 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2018-2XF42-2LA2
Rated operation power NEMA (EF011960)7.3549875
Voltage type for actuating (EF008242)DC
minimum cross-section in main circuit
● for auxiliary and control circuitspring-loaded terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 20 A
● without load current share typical0.8 W
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsSpring-type terminals
number of poles for main current circuit3
— with type of coordination 1 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 35 A
● at AWG cables for auxiliary contacts2x (20 ... 12)
product function short circuit protectionNo
● at AC in hot operating state per pole2.2 W
mechanical service life (switching cycles)
full-load current (FLA) for 3-phase AC motor
number of NC contacts for auxiliary contacts1
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 2.5 mm²)
power loss [W] for rated value of the current
type of voltage of the control supply voltageDC
● mirror contact according to IEC 60947-4-1Yes
● with low demand rate according to SN 3192040 %
Rated operation power at AC-3, 400 V (EF001364)7.5
Rated operation power at AC-4, 400 V (EF008496)5.5
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
● with high demand rate according to SN 3192073 %
Rated control supply voltage Us at DC (EF003980)['72', '125']
control version of the switch operating mechanismStandard A1 - A2
● up to 40 °C according to IEC 60077 rated value22 A
● up to 70 °C according to IEC 60077 rated value18 A
Rated operation current Ie at AC-1, 400 V (EF001393)22
Rated operation current Ie at AC-3, 400 V (EF001392)16
Rated operation current Ie at AC-4, 400 V (EF008495)11.5
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for short-circuit protection of the main circuit
● limited to 1 s switching at zero current maximum300 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum169 A; Use minimum cross-section acc. to AC-1 rated value
B10 value with high demand rate according to SN 319201 000 000
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
● limited to 10 s switching at zero current maximum128 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum92 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum74 A; Use minimum cross-section acc. to AC-1 rated value
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Spring clamp connection
— up to 690 V at ambient temperature 40 °C rated value22 A
— up to 690 V at ambient temperature 60 °C rated value20 A
● of main circuit with degree of pollution 3 rated value690 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)3
operating power for approx. 200000 operating cycles at AC-4
Number of normally closed contacts as main contact (EF001375)0
failure rate [FIT] with low demand rate according to SN 31920100 FIT
● at AC-1 at 400 V at ambient temperature 40 °C rated value22 A
● of the contactor with added auxiliary switch block typical10 000 000
operational current for approx. 200000 operating cycles at AC-4
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value690 V
Number of auxiliary contacts as normally open contact (EF001376)-
short-time withstand current in cold operating state up to 40 °C
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)1
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at DC
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
General Product ApprovalConfirmationKCEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesType Examination CertificateUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingMarine / ShippingotherRailwayDangerous GoodConfirmationSpecial Test CertificateType Test Certificates/Test ReportTransport InformationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top