Service time: Monday to Friday 9:00-18:00
3RT2015-1MB41-0KT0 - 3RT2015-1MB41-0KT0 SIEMENS COUPLING CONT., AC-3, 3KW/400V, 1NO, DC 24V, 0.85...1.85*US, 3-POLE, SZ S00 SCRE..
In Stock Hot Product

3RT2015-1MB41-0KT0

3RT2015-1MB41-0KT0 SIEMENS COUPLING CONT., AC-3, 3KW/400V, 1NO, DC 24V, 0.85...1.85*US, 3-POLE, SZ S00 SCRE..

$0.00USD
3957 in stock
Key Specifications
:
EAN:4011209847286
EMC:Functional Safety/Safety of Machinery
UPC:662643909135
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209847286
EMCFunctional Safety/Safety of Machinery
UPC662643909135
ETIM5
IDEA4
depth73 mm
width45 mm
UNSPSC14
eClass6
height58 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
● at DC6,7g / 5 ms, 4,2g / 10 ms
● solid0.5 ... 4 mm²
Group CodeR711
arcing time10 ... 15 ms
— upwards10 mm
● at AC-1
● at AC-3
Metal FactorLDP-----
— forwards10 mm
● at AC-3e
● at AC-6a
● stranded0.5 ... 4 mm²
Date5/11/2022Subject to change without notice© Copyright Siemens 2022
Product Group5330
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT contactors, 3-pole, up to 250 kW
last modified:2/15/2022
Net Weight (kg)0,297 Kg
operating power
— at the side0 mm
● rated value24 V
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
product function
required spacing
Country of originGermany
Marine / Shippingother
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
operating voltage
product extension
size of contactorS00
● initial value0.85
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Packaging Dimension50,00 x 61,50 x 77,50
Product Descriptionpower contactor, AC-3 7 A, 3 kW / 400 V 1 NO, 24 V DC 0.85-1.85* US, 3-pole, size S00, screw terminal not expandable with auxiliary switch
ambient temperature
operating frequency
operational current
product designationCoupling contactor
suitability for use
● at AC-1 maximum1 000 1/h
● at AC-2 maximum750 1/h
● at AC-3 maximum750 1/h
● at AC-4 maximum250 1/h
● at AC-3e maximum750 1/h
● auxiliary switchNo
● during operation-25 ... +60 °C
● full-scale value1.85
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
● for main contacts
● solid or stranded0.5 ... 4 mm²
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
— at 24 V rated value15 A
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
product type designation3RT2
surge voltage resistance
— at 110 V rated value1.5 A
— at 220 V rated value0.6 A
— at 230 V rated value1.5 kW
— at 400 V rated value7 A
— at 440 V rated value0.42 A
— at 500 V rated value6 A
— at 600 V rated value0.42 A
— at 690 V rated value4.9 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 230 V rated value10 A
● at 400 V rated value2.6 A
● at 480 V rated value4.8 A
● at 500 V rated value2 A
● at 600 V rated value0.15 A
● at 690 V rated value1.8 A
● for 3-phase AC motor
● of contactor typical30 000 000
relative humidity minimum10 %
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
● for auxiliary contacts
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
Package size unit of measureMM
control supply voltage at DC
operational current at AC-15
operational current at DC-12
operational current at DC-13
— at 110/120 V rated value0.25 hp
— at 200/208 V rated value1.5 hp
— at 220/230 V rated value2 hp
— at 460/480 V rated value3 hp
— at 575/600 V rated value5 hp
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
● at 1 current path at DC-1
● for single-phase AC motor
● with side-by-side mounting
● at AC-3 rated value maximum690 V
● of main circuit rated value6 kV
proportion of dangerous failures
shock resistance with sine pulse
● at AC in hot operating state1.2 W
● at AC-3e rated value maximum690 V
● at AC-4 at 400 V rated value6.5 A
● safety-related switching OFFYes
operating apparent power at AC-6a
closing power of magnet coil at DC1.6 W
holding power of magnet coil at DC1.6 W
yielded mechanical performance [hp]
● at AWG cables for main contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
operational current at AC-12 maximum10 A
● at AC-5a up to 690 V rated value15.8 A
● at AC-5b up to 400 V rated value5.8 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT2015-1MB41-0KT0
● at 1 current path at DC-3 at DC-5
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
● without load current share typical1.6 W
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit3
— with type of coordination 1 requiredgG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
● at AC in hot operating state per pole0.4 W
mechanical service life (switching cycles)
● with 2 current paths in series at DC-1
● with 3 current paths in series at DC-1
full-load current (FLA) for 3-phase AC motor
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm²
power loss [W] for rated value of the current
type of voltage of the control supply voltageDC
● mirror contact according to IEC 60947-4-1No
● with low demand rate according to SN 3192040 %
● with high demand rate according to SN 3192073 %
control version of the switch operating mechanismStandard A1 - A2
● with 2 current paths in series at DC-3 at DC-5
● with 3 current paths in series at DC-3 at DC-5
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for short-circuit protection of the main circuit
● limited to 1 s switching at zero current maximum120 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
B10 value with high demand rate according to SN 319201 000 000
connectable conductor cross-section for main contacts
● limited to 10 s switching at zero current maximum67 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum52 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum43 A; Use minimum cross-section acc. to AC-1 rated value
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
— up to 230 V for current peak value n=20 rated value4 A
— up to 230 V for current peak value n=30 rated value2.7 A
— up to 400 V for current peak value n=20 rated value4 A
— up to 400 V for current peak value n=30 rated value2.7 A
— up to 500 V for current peak value n=20 rated value3.8 A
— up to 500 V for current peak value n=30 rated value2.5 A
— up to 690 V for current peak value n=20 rated value3.6 A
— up to 690 V for current peak value n=30 rated value2.4 A
● up to 230 V for current peak value n=20 rated value1.5 kVA
● up to 230 V for current peak value n=30 rated value1 kVA
● up to 400 V for current peak value n=20 rated value2.7 kVA
● up to 400 V for current peak value n=30 rated value1.8 kVA
● up to 500 V for current peak value n=20 rated value3.3 kVA
● up to 500 V for current peak value n=30 rated value2.2 kVA
● up to 690 V for current peak value n=20 rated value4.3 kVA
● up to 690 V for current peak value n=30 rated value2.9 kVA
— up to 690 V at ambient temperature 40 °C rated value18 A
— up to 690 V at ambient temperature 60 °C rated value16 A
connectable conductor cross-section for auxiliary contacts
● of main circuit with degree of pollution 3 rated value690 V
operating power for approx. 200000 operating cycles at AC-4
failure rate [FIT] with low demand rate according to SN 31920100 FIT
● at AC-1 at 400 V at ambient temperature 40 °C rated value18 A
operational current for approx. 200000 operating cycles at AC-4
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value690 V
minimum cross-section in main circuit at maximum AC-1 rated value2.5 mm²
short-time withstand current in cold operating state up to 40 °C
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
number of NO contacts for auxiliary contacts instantaneous contact1
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
REACH Art. 33 Duty to inform according to the current list of candidatesReach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
operating range factor control supply voltage rated value of magnet coil at DC
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1400 V
General Product ApprovalConfirmationKCEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesType Examination CertificateUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingMarine / ShippingotherRailwayDangerous GoodConfirmationVibration and ShockTransport InformationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top