Service time: Monday to Friday 9:00-18:00
3RT1476-6NF36 - 3RT1476-6NF36 SIEMENS Contactor, AC-1, 690 A/690 V/40 °C, S12, 3-pole, 96-127 V AC/DC, PLC-IN optional, with..
In Stock Hot Product

3RT1476-6NF36

3RT1476-6NF36 SIEMENS Contactor, AC-1, 690 A/690 V/40 °C, S12, 3-pole, 96-127 V AC/DC, PLC-IN optional, with..

$0.00USD
3029 in stock
Key Specifications
:Confirmation
EAN:4011209510203
UPC:754554774077
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209510203
UPC754554774077
ETIM5
IDEA4
depth225 mm
otherRailway
width160 mm
UNSPSC14
eClass6
height214 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
Group CodeR711
arcing time10 ... 15 ms
— upwards10 mm
● at AC-1
● at AC-3
Metal FactorLFO-----
— forwards20 mm
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
● stranded70 ... 240 mm²
Date5/14/2022Subject to change without notice© Copyright Siemens 2022
MiscellaneousSpecial Test Certificate
Product Group3706
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A
last modified:3/15/2022
● attachable4
Net Weight (kg)10,438 Kg
number of holes1
type of voltageAC/DC
— at the side0 mm
● rated value96 ... 127 V
fastening methodscrew fixing
product function
required spacing
Country of originGermany
Marine / Shippingother
diameter of holes11 mm
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
product extension
size of contactorS12
● initial value0.8
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Packaging Dimension289,00 x 233,00 x 272,00
Product DescriptionContactor, AC-1, 690 A/690 V/40 °C, S12, 3-pole, 96-127 V AC/DC, PLC-IN optional, with varistor, 2 NO+2 NC, Connection rail/ screw terminal
ambient temperature
operational current
product designationContactor
● auxiliary switchYes
● during operation-25 ... +60 °C
● full-scale value1.1
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
● solid or stranded70 ... 240 mm²
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
width of connection bar25 mm
● at 24 V rated value10 A
● at 48 V rated value2 A
● at 60 V rated value2 A
General Product ApprovalEMC
product type designation3RT14
surge voltage resistance
— at 400 V rated value170 A
— at 690 V rated value170 A
● at 110 V rated value1 A
● at 125 V rated value0.9 A
● at 220 V rated value0.3 A
● at 230 V rated value6 A
● at 400 V rated value3 A
● at 50 Hz rated value96 ... 127 V
● at 500 V rated value2 A
● at 60 Hz rated value96 ... 127 V
● at 600 V rated value0.1 A
● at 690 V rated value1 A
● of contactor typical10 000 000
relative humidity minimum10 %
● instantaneous contact2
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
● for auxiliary contacts
Standard lead time ex-works50 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
thickness of connection bar6 mm
Package size unit of measureMM
Type Examination CertificateUK Declaration of Conformity
control supply voltage at AC
control supply voltage at DC
operational current at AC-15
operational current at DC-13
● for main current circuitConnection bar
Substance Prohibitance (Date)05/01/2012
type of electrical connection
design of the surge suppressorwith varistor
● with side-by-side mounting
● of main circuit rated value8 kV
shock resistance with sine pulse
● at AC in hot operating state185.7 W
closing power of magnet coil at DC800 W
holding power of magnet coil at DC3.6 W
operating frequency at AC-1 maximum600 1/h
● at AWG cables for main contacts2/0 ... 500 kcmil
operational current at AC-12 maximum10 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT1476-6NF36
Functional Safety/Safety of MachineryDeclaration of Conformity
Rated operation power NEMA (EF011960)-
Voltage type for actuating (EF008242)AC/DC
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgR: 710 A (690 V, 100 kA)
● without load current share typical3.6 W
number of NC contacts for main contacts0
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit3
type of voltage for main current circuitAC
— with type of coordination 1 requiredgG: 800 A (690 V, 50 kA)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
product function short circuit protectionNo
● at AC in hot operating state per pole61.9 W
mechanical service life (switching cycles)
apparent holding power of magnet coil at AC
apparent pick-up power of magnet coil at AC
number of NC contacts for auxiliary contacts2
number of NO contacts for auxiliary contacts2
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm²
power loss [W] for rated value of the current
type of voltage of the control supply voltageAC/DC
● mirror contact according to IEC 60947-4-1Yes
Rated operation power at AC-3, 400 V (EF001364)-
Rated operation power at AC-4, 400 V (EF008496)-
Rated control supply voltage Us at DC (EF003980)['96', '127']
control version of the switch operating mechanismPLC-IN or Standard A1 - A2 (adjustable)
type of PLC-control input according to IEC 60947-1Type 2
Rated operation current Ie at AC-1, 400 V (EF001393)690
Rated operation current Ie at AC-3, 400 V (EF001392)170
Rated operation current Ie at AC-4, 400 V (EF008495)-
Region Specific PriceGroup / Headquarter Price Group41B / 41B
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
● for short-circuit protection of the main circuit
Rated control supply voltage Us at AC 50HZ (EF003978)['96.0', '127.0']
Rated control supply voltage Us at AC 60HZ (EF003979)['96.0', '127.0']
connectable conductor cross-section for main contacts
inductive power factor with closing power of the coil
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
Type of electrical connection of main circuit (EF006819)-
inductive power factor with the holding power of the coil
— up to 690 V at ambient temperature 40 °C rated value690 A
— up to 690 V at ambient temperature 55 °C rated value600 A
— up to 690 V at ambient temperature 60 °C rated value600 A
connectable conductor cross-section for auxiliary contacts
● of main circuit with degree of pollution 3 rated value1 000 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)3
Number of normally closed contacts as main contact (EF001375)-
● of the contactor with added auxiliary switch block typical10 000 000
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value500 V
Number of auxiliary contacts as normally open contact (EF001376)2
minimum cross-section in main circuit at maximum AC-1 rated value480 mm²
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
consumed current at PLC-control input according to IEC 60947-1 maximum20 mA
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value of magnet coil at AC
operating range factor control supply voltage rated value of magnet coil at DC
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
design of the miniature circuit breaker for short-circuit protection of the auxiliary switch requiredgG: 10 A (230 V, 400 A)
General Product ApprovalEMCConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingType Examination CertificateUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationConfirmationotherRailwayMiscellaneousSpecial Test CertificateGeneral Product Approval

Product Description

SIRIUS Contactor, 690A/AC-1 drive AC/DC UC 96-127V Auxiliary contacts 2NA+2NC 3 poles, size S12 Electronic drive bar connections With SPS DC24V interface. Manufactured to order. Non-Cancelable Non-Ret
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top