Key Specifications
:Confirmation
EAN:4011209508590
UPC:Not available
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209508590
UPCNot available
ETIM5
IDEA4
depth225 mm
width160 mm
UNSPSC15
eClass6
height214 mm
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
Group CodeR711
arcing time10 ... 15 ms
— upwards10 mm
● at AC-1
● at AC-3
Date5/8/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLFO-----
— forwards20 mm
● at AC-6a
● stranded70 ... 240 mm²
Product Group3706
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
closing delay
opening delay
— downwards10 mm
Commodity Code85364900
Product familySIRIUS 3RT contactors, 3-pole, up to 250 kW
last modified:12/23/2021
Net Weight (kg)9,463 Kg
number of holes1
operating power
— at the side0 mm
fastening methodscrew fixing
product function
required spacing
Country of originGermany
Marine / Shippingother
diameter of holes11 mm
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
operating voltage
product extension
size of contactorS12
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
● for live parts
● of magnet coilScrew-type terminals
Packaging Dimension289,00 x 233,00 x 272,00
Product DescriptionPower contactor, AC-3 500 A, 250 kW / 400 V without coil Auxiliary contacts 2 NO + 2 NC 3-pole, size S12 main conductor: Busbar connections auxiliary conductor: Screw terminals
ambient temperature
operating frequency
operational current
product designationPower contactor
suitability for use
● at AC-1 maximum500 1/h
● at AC-2 maximum170 1/h
● at AC-3 maximum420 1/h
● at AC-4 maximum130 1/h
● auxiliary switchYes
● during operation-25 ... +60 °C
— solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
● solid or stranded0.5 ... 4 mm²
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
width of connection bar25 mm
— at 24 V rated value400 A
● at 24 V rated value10 A
● at 48 V rated value6 A
● at 60 V rated value6 A
General Product ApprovalEMC
Special Test Certificate
product type designation3RT1
surge voltage resistance
— at 110 V rated value33 A
— at 220 V rated value3.8 A
— at 230 V rated value160 kW
— at 400 V rated value500 A
— at 440 V rated value0.9 A
— at 500 V rated value500 A
— at 600 V rated value0.6 A
— at 690 V rated value450 A
● at 110 V rated value3 A
● at 125 V rated value2 A
● at 220 V rated value1 A
● at 230 V rated value6 A
● at 400 V rated value175 A
● at 480 V rated value477 A
● at 500 V rated value2 A
● at 600 V rated value0.15 A
● at 690 V rated value150 A
● for 3-phase AC motor
● of contactor typical10 000 000
relative humidity minimum10 %
— at 1000 V rated value180 A
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
● for auxiliary contacts
Standard lead time ex-works50 Day/Days
Surcharge for Raw MaterialsNone
no-load switching frequency
thickness of connection bar6 mm
Package size unit of measureMM
Type Examination Certificate
operational current at AC-15
operational current at DC-12
operational current at DC-13
— at 200/208 V rated value150 hp
— at 220/230 V rated value200 hp
— at 460/480 V rated value400 hp
— at 575/600 V rated value500 hp
● for main current circuitConnection bar
Substance Prohibitance (Date)05/01/2012
type of electrical connection
● at 1 current path at DC-1
● with side-by-side mounting
● at AC-3 rated value maximum1 000 V
● of main circuit rated value8 kV
shock resistance with sine pulse
● at AC in hot operating state165 W
● at AC-4 at 400 V rated value430 A
● safety-related switching OFFNo
operating apparent power at AC-6a
yielded mechanical performance [hp]
● at AWG cables for main contacts2/0 ... 500 kcmil
operational current at AC-12 maximum10 A
● at AC-5a up to 690 V rated value536 A
● at AC-5b up to 400 V rated value415 A
● of auxiliary circuit rated value6 kV
Article Number (Market Facing Number)3RT1076-6LA06
Functional Safety/Safety of MachineryDeclaration of Conformity
Rated operation power NEMA (EF011960)294.1995
Voltage type for actuating (EF008242)AC/DC
● at 1 current path at DC-3 at DC-5
● for auxiliary and control circuitscrew-type terminals
● function module for communicationNo
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG: 500 A (690 V, 100 kA), aM: 500 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
number of NO contacts for main contacts3
reference code according to IEC 81346-2Q
shock resistance at rectangular impulse
● at contactor for auxiliary contactsScrew-type terminals
number of poles for main current circuit3
— with type of coordination 1 requiredgG: 630 A (690 V, 100 kA)
● at AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
● at AC in hot operating state per pole55 W
mechanical service life (switching cycles)
● with 2 current paths in series at DC-1
● with 3 current paths in series at DC-1
full-load current (FLA) for 3-phase AC motor
type of connectable conductor cross-sections
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● finely stranded with core end processing0.5 ... 2.5 mm²
power loss [W] for rated value of the current
type of voltage of the control supply voltageAC/DC
● mirror contact according to IEC 60947-4-1Yes
Rated operation power at AC-3, 400 V (EF001364)250.0
Rated operation power at AC-4, 400 V (EF008496)250.0
Rated control supply voltage Us at DC (EF003980)['-', '-']
control version of the switch operating mechanismWithout operating mechanism
● with 2 current paths in series at DC-3 at DC-5
● with 3 current paths in series at DC-3 at DC-5
Rated operation current Ie at AC-1, 400 V (EF001393)610
Rated operation current Ie at AC-3, 400 V (EF001392)500
Rated operation current Ie at AC-4, 400 V (EF008495)430
Region Specific PriceGroup / Headquarter Price Group41B / 41B
contact rating of auxiliary contacts according to ULA600 / Q600
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
● for short-circuit protection of the main circuit
● limited to 1 s switching at zero current maximum7 484 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum7 484 A; Use minimum cross-section acc. to AC-1 rated value
B10 value with high demand rate according to SN 319201 000 000
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
connectable conductor cross-section for main contacts
● limited to 10 s switching at zero current maximum5 978 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum3 765 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum2 887 A; Use minimum cross-section acc. to AC-1 rated value
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
— up to 230 V for current peak value n=20 rated value414 A
— up to 230 V for current peak value n=30 rated value276 A
— up to 400 V for current peak value n=20 rated value414 A
— up to 400 V for current peak value n=30 rated value276 A
— up to 500 V for current peak value n=20 rated value414 A
— up to 500 V for current peak value n=30 rated value276 A
— up to 690 V for current peak value n=20 rated value414 A
— up to 690 V for current peak value n=30 rated value276 A
● up to 230 V for current peak value n=20 rated value160 000 kVA
● up to 230 V for current peak value n=30 rated value110 000 VA
● up to 400 V for current peak value n=20 rated value280 000 VA
● up to 400 V for current peak value n=30 rated value190 000 VA
● up to 500 V for current peak value n=20 rated value350 000 VA
● up to 500 V for current peak value n=30 rated value230 000 VA
● up to 690 V for current peak value n=20 rated value490 000 VA
● up to 690 V for current peak value n=30 rated value330 000 VA
Type of electrical connection of main circuit (EF006819)-
— up to 1000 V for current peak value n=20 rated value180 A
— up to 1000 V for current peak value n=30 rated value180 A
● up to 1000 V for current peak value n=20 rated value310 000 VA
● up to 1000 V for current peak value n=30 rated value310 000 VA
— up to 690 V at ambient temperature 40 °C rated value610 A
— up to 690 V at ambient temperature 60 °C rated value550 A
connectable conductor cross-section for auxiliary contacts
— up to 1000 V at ambient temperature 40 °C rated value200 A
— up to 1000 V at ambient temperature 60 °C rated value200 A
● of main circuit with degree of pollution 3 rated value1 000 V
● positively driven operation according to IEC 60947-5-1No
Number of main contacts as normally open contact (EF001374)3
operating power for approx. 200000 operating cycles at AC-4
Number of normally closed contacts as main contact (EF001375)-
● at AC-1 at 400 V at ambient temperature 40 °C rated value610 A
● of the contactor with added auxiliary switch block typical10 000 000
operational current for approx. 200000 operating cycles at AC-4
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
● of auxiliary circuit with degree of pollution 3 rated value500 V
Number of auxiliary contacts as normally open contact (EF001376)2
minimum cross-section in main circuit at maximum AC-1 rated value370 mm²
short-time withstand current in cold operating state up to 40 °C
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Number of auxiliary contacts as normally closed contact (EF001377)2
number of NC contacts for auxiliary contacts instantaneous contact2
number of NO contacts for auxiliary contacts instantaneous contact2
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1690 V
General Product ApprovalEMCConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingType Examination CertificateUK Declaration of ConformityType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherConfirmationMiscellaneousMiscellaneousRailwaySpecial Test CertificateGeneral Product Approval

Product Description