3RT1054-1AP30 - 3RT1054-1AP30 SIEMENS CONTACTOR, 55KW/400V/AC-3, AC(40...60HZ)/DC OPERATION UC 220...240V W/O AUXILIARY CON..
In Stock Hot Product

3RT1054-1AP30

3RT1054-1AP30 SIEMENS CONTACTOR, 55KW/400V/AC-3, AC(40...60HZ)/DC OPERATION UC 220...240V W/O AUXILIARY CON..

$0.00USD
3002 in stock
Key Specifications
Depth:170 mm
Width:120 mm
Height:172 mm
— at AC:8,5g / 5 ms, 4,2g / 10 ms
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Depth170 mm
Width120 mm
Height172 mm
— at AC8,5g / 5 ms, 4,2g / 10 ms
— at DC8,5g / 5 ms, 4,2g / 10 ms
— solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
● at AC2 000 1/h
● at DC2 000 1/h
Arcing time10 ... 15 ms
● at AC-1
● at AC-3
— strandedmax. 2x 70 mm²
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
Closing delay
Mounting typescrew fixing
Opening delay
Operating power
— at the side10 mm
● rated value1 000 V
Required spacing
Shock resistance
● on the frontIP00
Operating current
Size of contactorS6
Insulation voltage
product brand nameSIRIUS
● during storage-55 ... +80 °C
Ambient temperature
Degree of pollution3
Operating frequency
Product designationpower contactor
Protection class IP
● at AC-1 maximum800 1/h
● at AC-2 maximum400 1/h
● at AC-3 maximum1 000 1/h
● at AC-4 maximum130 1/h
● of the terminalIP00
● with sine pulse
● at AC-1 at 400 V
● during operation-25 ... +60 °C
Number of NC contacts
Number of NO contacts
● for main contacts
● for grounded parts
Design of the fuse link
— at 24 V rated value160 A
● at 24 V rated value10 A
● at 60 V rated value6 A
— at 110 V rated value18 A
— at 230 V rated value37 kW
— at 400 V rated value115 A
— at 500 V rated value81 kW
— at 690 V rated value115 A
● at 110 V rated value3 A
● at 220 V rated value1 A
● at 230 V rated value6 A
● at 400 V rated value54 A
● at 50 Hz rated value220 ... 240 V
● at 60 Hz rated value220 ... 240 V
● at 690 V rated value48 A
● of contactor typical10 000 000
— at 1000 V rated value53 A
— instantaneous contact0
● Side-by-side mountingYes
Operating current at AC-15
Operating current at DC-12
Operating current at DC-13
● at rectangular impulse
● for auxiliary contacts
No-load switching frequency
Control supply voltage at AC
Control supply voltage at DC
● for main current circuitscrew-type terminals
Type of electrical connection
● at 1 current path at DC-1
Design of the surge suppressorwith varistor
● at AC-2 at 400 V rated value84 kW
● at 40 °C minimum permissible70 mm²
● at 60 °C minimum permissible50 mm²
Closing power of magnet coil at DC360 W
Holding power of magnet coil at DC5.2 W
Operating current at AC-12 maximum10 A
— at 230 V at 60 °C rated value53 kW
— at 690 V at 60 °C rated value159 kW
— at 1000 V at 60 °C rated value131 W
Surge voltage resistance rated value8 kV
● at 1 current path at DC-3 at DC-5
— with type of assignment 2 requiredfuse gL/gG: 315 A
Number of NC contacts for main contacts0
Number of NO contacts for main contacts3
● at AWG conductors for main contacts2x 1/0
— with type of coordination 1 requiredfuse gL/gG: 355 A
Mechanical service life (switching cycles)
Thermal short-time current limited to 10 s1 100 A
● with 2 current paths in series at DC-1
● with 3 current paths in series at DC-1
Apparent holding power of magnet coil at AC5.8 V·A
Apparent pick-up power of magnet coil at AC300 V·A
Type of connectable conductor cross-sections
— finely stranded with core end processingmax. 1x 50, 1x 70 mm²
● at AWG conductors for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
Type of voltage of the control supply voltageAC/DC
— at ambient temperature 40 °C rated value160 A
● for auxiliary and control current circuitscrew-type terminals
Control supply voltage frequency 1 rated value50 Hz
Control supply voltage frequency 2 rated value60 Hz
maximum permissible voltage for safe isolation
— finely stranded without core end processingmax. 1x 50, 1x 70 mm²
● with 2 current paths in series at DC-3 at DC-5
● with 3 current paths in series at DC-3 at DC-5
Contact rating of auxiliary contacts according to ULA600 / Q600
● for short-circuit protection of the main circuit
Inductive power factor with closing power of the coil0.9
● between coil and main contacts acc. to EN 60947-1690 V
Installation altitude at height above sea level maximum2 000 m
Inductive power factor with the holding power of the coil0.8
— up to 690 V at ambient temperature 40 °C rated value160 A
— up to 690 V at ambient temperature 60 °C rated value140 A
— up to 1000 V at ambient temperature 40 °C rated value80 A
— up to 1000 V at ambient temperature 60 °C rated value80 A
Connectable conductor cross-section in main circuit at AC-1
Operating power for approx. 200000 operating cycles at AC-4
Operating current for approx. 200000 operating cycles at AC-4
● of the contactor with added auxiliary switch block typical10 000 000
● for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Operating range factor control supply voltage rated value of magnet coil at AC
Operating range factor control supply voltage rated value of magnet coil at DC0.8 ... 1.1
● of the contactor with added electronics-compatible auxiliary switch block typical5 000 000
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor7 W

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide