Service time: Monday to Friday 9:00-18:00
3RS2040-2GW50 - 3RS2040-2GW50 SIEMENS temperature monitoring relay Pt100/1000 KTY83/84, NTC 2 threshold values digitally adj..
In Stock Hot Product

3RS2040-2GW50

3RS2040-2GW50 SIEMENS temperature monitoring relay Pt100/1000 KTY83/84, NTC 2 threshold values digitally adj..

$0.00USD
3478 in stock
Key Specifications
:VersionClassificationeClass627-37-18-10eClass7.127-37-18-10eClass827-37-18-10eClass927-37-18-10eClass9.127-37-18-10ETIM5EC001446ETIM6EC001446ETIM7EC001446ETIM8EC001446IDEA45282UNSPSC1439-12-22-29UNSPSC1539-12-22-29
EAN:4011209626324
UPC:754554871240
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
VersionClassificationeClass627-37-18-10eClass7.127-37-18-10eClass827-37-18-10eClass927-37-18-10eClass9.127-37-18-10ETIM5EC001446ETIM6EC001446ETIM7EC001446ETIM8EC001446IDEA45282UNSPSC1439-12-22-29UNSPSC1539-12-22-29
EAN4011209626324
UPC754554871240
ETIM5
IDEA4
depth91 mm
width45 mm
UNSPSC14
eClass6
height108 mm
● at DC24 ... 240 V
Group CodeR711
Confirmation
Metal FactorLAO-----
● at 50 Hz24 ... 240 V
● at 60 Hz24 ... 240 V
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5882
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85364900
Product familyRelays, digitally adjustable for 1 sensor
last modified:5/1/2021
Net Weight (kg)0,275 Kg
Depth (EF000049)91.0
Width (EF000008)45.0
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
product functiontemperature monitoring
● error memoryYes
Country of originGermany
Height (EF000040)108.0
● initial value-58 °F
LKZ_FDB/ CatalogIDCC-IC10
PLM Effective DateProduct phase-out since: 01.10.2020
Packaging Quantity1
product brand nameSIRIUS
● external resetYes
Packaging Dimension53,00 x 111,50 x 105,00
Product Descriptiontemperature monitoring relay Pt100/1000 KTY83/84, NTC 2 threshold values digitally adjustable -58 °F to 932 °F 24 - 240 V AC/DC 2 x 1 CO + 1 NO, width 45 mm spring-loaded terminal !!!phased-out product!!! the preferred successor is 3RS2600-2BW30
ambient temperature
product designationTemperature monitoring relay
● during operation-25 ... +60 °C
● full-scale value932 °F
Product Lifecycle (PLM)PM400:Phase Out Started
General Product ApprovalDeclaration of Conformity
control supply voltage 1
product type designation3RS20
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
number of measuring circuits1
Substance Prohibitance (Date)05/01/2012
type of electrical connection
control supply voltage 1 at AC
design of the sensor connectablePT100/1000, KTY83/84, NTC (resistance sensors)
With detachable clamps (EF003340)true
measurable Fahrenheit temperature
External reset possible (EF003426)true
Article Number (Market Facing Number)3RS2040-2GW50
Resistance measuring range (EF011955)-
Voltage type for actuating (EF008242)AC/DC
● for auxiliary and control circuitspring-loaded terminals
Error registration possible (EF003423)true
Temperature measuring range (EF009788)-
Type of electric connection (EF003961)Spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
Number of measuring circuits (EF003425)1
reference code according to IEC 81346-2K
number of CO contacts for auxiliary contacts2
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts1
type of electrical connection plug-in socketYes
Rated control supply voltage Us at DC (EF003980)['24', '240']
Number of contacts as change-over contact (EF008257)2
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Rated control supply voltage Us at AC 50HZ (EF003978)['24', '240']
Rated control supply voltage Us at AC 60HZ (EF003979)['24', '240']
Number of contacts as normally open contact (EF008256)1
Number of contacts as normally closed contact (EF008255)0
supply voltage frequency for auxiliary and control circuit50 ... 60 Hz
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Dicyclohexyl phthala... CAS-No. 84-61-7 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Dicyclohexyl phthalate (DCHP)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
General Product ApprovalDeclaration of ConformityTest CertificatesConfirmationType Test Certificates/Test ReportotherConfirmationGeneral Product Approval

Product Description

TEMPERATURE MONITORING RELAY PT100/1000, KTY83/84, NTC 2 THRESHOLD VALUES, DIGITAL -58 DEGR. F TO 932 DEGR. F 24-240V AC/DC. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Confirmation

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top