Key Specifications
:VersionClassificationeClass627-37-18-10eClass7.127-37-18-10eClass827-37-18-10eClass927-37-18-10eClass9.127-37-18-10ETIM5EC001446ETIM6EC001446ETIM7EC001446ETIM8EC001446IDEA45282UNSPSC1439-12-22-29UNSPSC1539-12-22-29
EAN:4011209535350
UPC:754554869995
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
VersionClassificationeClass627-37-18-10eClass7.127-37-18-10eClass827-37-18-10eClass927-37-18-10eClass9.127-37-18-10ETIM5EC001446ETIM6EC001446ETIM7EC001446ETIM8EC001446IDEA45282UNSPSC1439-12-22-29UNSPSC1539-12-22-29
EAN4011209535350
UPC754554869995
ETIM5
IDEA4
depth91 mm
width22.5 mm
UNSPSC14
eClass6
height92 mm
Group CodeR711
Confirmation
Metal FactorLAO-----
Date5/14/2022Subject to change without notice© Copyright Siemens 2022
Product Group5882
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85364900
Product familyRelays, analogically adjustable for 1 sensor
last modified:2/1/2021
Net Weight (kg)0,191 Kg
type of voltageAC
Depth (EF000049)91.0
Width (EF000008)22.5
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
product function
● error memoryNo
Country of originGermany
Height (EF000040)92.0
● initial value0 °C
LKZ_FDB/ CatalogIDCC-IC10
PLM Effective DateProduct phase-out since: 01.10.2020
Packaging Quantity1
product brand nameSIRIUS
● external resetNo
Packaging Dimension29,00 x 99,00 x 107,00
Product Descriptiontemperature monitoring relay Pt100, undershoot 1 threshold value, width 22.5 mm 0 °C to 200 °C 110-120/220-240 V AC 1 NO + 1 NC, quiescent current principle screw terminal !!!phased-out product!!! the preferred successor is 3RS2500-1AW30
product designationTemperature monitoring relay
● full-scale value200 °C
design of the productUndershoot, 1 threshold value
measurable temperature
power loss [W] maximum2 W
Product Lifecycle (PLM)PM400:Phase Out Started
General Product ApprovalDeclaration of Conformity
product type designation3RS10
● at 50 Hz rated value110 V
● at 60 Hz rated value110 V
Export Control RegulationsAL : N / ECCN : N
power loss [V∙A] maximum4 VA
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
number of measuring circuits1
Substance Prohibitance (Date)05/01/2012
control supply voltage 1 at AC
control supply voltage 2 at AC
design of the sensor connectablePT100 (resistance sensor)
With detachable clamps (EF003340)true
External reset possible (EF003426)false
ambient temperature during operation-25 ... +60 °C
Article Number (Market Facing Number)3RS1010-1CK20
Resistance measuring range (EF011955)-
Voltage type for actuating (EF008242)AC
Error registration possible (EF003423)false
Temperature measuring range (EF009788)-
Type of electric connection (EF003961)Screw connection
WEEE (2012/19/EU) Take-Back ObligationYes
Number of measuring circuits (EF003425)1
reference code according to IEC 81346-2K
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
type of electrical connection plug-in socketYes
Rated control supply voltage Us at DC (EF003980)['-', '-']
Number of contacts as change-over contact (EF008257)0
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Rated control supply voltage Us at AC 50HZ (EF003978)['110', '230']
Rated control supply voltage Us at AC 60HZ (EF003979)['110', '230']
Number of contacts as normally open contact (EF008256)1
Number of contacts as normally closed contact (EF008255)1
supply voltage frequency for auxiliary and control circuit50 ... 60 Hz
type of electrical connection for auxiliary and control circuitscrew-type terminals
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
General Product ApprovalDeclaration of ConformityTest CertificatesConfirmationType Test Certificates/Test ReportotherConfirmationGeneral Product Approval

Product Description

SIRIUS Temperature monitoring relay for PT100, default overshoot 1 threshold, width 22.5 mm 0~C-200~C, 110-120/220-240V AC 1 NA + 1 NC, NC circuit screw connection. Manufactured to order. Non-Cancelab