Service time: Monday to Friday 9:00-18:00
3RR2142-2AA30 - 3RR2142-2AA30 SIEMENS Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment A..
In Stock Hot Product

3RR2142-2AA30

3RR2142-2AA30 SIEMENS Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment A..

$0.00USD
4038 in stock
Key Specifications
:Confirmation
EAN:4011209787339
UPC:662643908619
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4011209787339
UPC662643908619
ETIM5
IDEA4
depth92 mm
width45 mm
● 14 ... 40 A
● 24 ... 40 A
UNSPSC14
eClass6
height109 mm
— solid1x (1 ... 10 mm²)
Group CodeR711
— upwards0 mm
● at 24 V3 A
Metal FactorLAO-----
— forwards0 mm
● at 125 V0.2 A
● at 230 V3 A
● at 250 V0.1 A
● at 400 V3 A
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group5343
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
— backwards0 mm
— downwards0 mm
Commodity Code85364900
Product familyCurrent and active current monitoring
last modified:1/18/2021
Net Weight (kg)0,260 Kg
— at the side0 mm
Depth (EF000049)92.0
Width (EF000008)45.0
fastening methoddirect mounting
required spacing
shock resistance15g / 11 ms
● on the frontIP20
Country of originCzech Republic
Height (EF000040)109.0
Marine / Shippingother
mounting positionany
● when starting0 ... 60 s
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-40 ... +80 °C
● for live parts
Packaging Dimension103,00 x 117,00 x 60,00
Product DescriptionMonitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment Apparent current monitoring 4...40 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system
ambient temperature
product designationMonitoring relays
protection class IP
● of the terminalIP20
vibration resistance10 ... 55 Hz / 0.35 mm
● during operation-25 ... +60 °C
design of the productanalogically adjustable, 2-phase current monitoring
number of CO contacts
● for main contacts
● solid or stranded1 ... 10 mm²
supply voltage 1 at AC
● for grounded parts
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
product type designation3RR2
relative repeat accuracy2 %
● at 50 Hz rated value24 V
● at 60 Hz rated value24 V
Declaration of ConformityTest Certificates
temperature drift per °C0.1 %/°C
Export Control RegulationsAL : N / ECCN : N
supply voltage frequency 150 ... 60 Hz
● for auxiliary contacts1
Standard lead time ex-works60 Day/Days
Surcharge for Raw MaterialsNone
operating power rated value2.5 W
Package size unit of measureMM
● for main current circuitspring-loaded terminals
Substance Prohibitance (Date)10/01/2009
type of electrical connection
adjustable response delay time
type of current for monitoringAC
● with side-by-side mounting
With detachable clamps (EF003340)true
supply voltage 1 at DC rated value24 V
operational current at 17 V minimum5 mA
● at AWG cables for main contacts1x (18 ... 8)
Current measurement range (EF000417)['4.0', '40.0']
operating apparent power rated value4 VA
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RR2142-2AA30
EMC immunity according to IEC 60947-1ambience A (industrial sector)
Voltage type for actuating (EF008242)AC/DC
type of voltage of the supply voltageAC/DC
● for auxiliary and control circuitspring-loaded terminals
Type of electric connection (EF003961)Spring clamp connection
WEEE (2012/19/EU) Take-Back ObligationYes
protocol is supported IO-Link protocolNo
External current transformer (EF001923)-
reference code according to IEC 81346-2K
● with lower or upper limit violation0 ... 30 s
Max. permitted off-delay time (EF008191)30
● at AWG cables for auxiliary contacts2x (24 ... 16)
Function DC-current hysteresis (EF003411)false
Min. adjustable off-delay time (EF008192)0
adjustable current response value current
Three-phase hysteresis possible (EF003395)false
● with degree of pollution 3 rated value690 V
Single-phase hysteresis possible (EF003394)false
tightening torque with screw-type terminals0.8 ... 1.2 N·m
Three-phase over current possible (EF003408)false
type of connectable conductor cross-sections
— finely stranded with core end processing1x (1 ... 6 mm²)
● finely stranded with core end processing1 ... 6 mm²
Single-phase over current possible (EF003407)false
Three-phase under current possible (EF003406)false
Single-phase under current possible (EF003405)false
— finely stranded without core end processing1x (1 ... 6 mm²)
● finely stranded without core end processing1 ... 6 mm²
Rated control supply voltage Us at DC (EF003980)['-', '24']
ampacity of the semiconductor output in SIO mode200 mA
EMC emitted interference according to IEC 60947-1ambience A (industrial sector)
mechanical service life (switching cycles) typical10 000 000
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
size of contactor can be combined company-specificS0
type of voltage supply via input/output link masterNo
Contains function DC-voltage over current (EF003410)false
Max. permitted delay-on energization time (EF008189)60
Number of contacts as change-over contact (EF008257)-
Region Specific PriceGroup / Headquarter Price Group41H / 41H
contact rating of auxiliary contacts according to ULB300 / R300
Contains function DC-voltage under current (EF003409)false
Min. adjustable delay-on energization time (EF008190)0
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '24']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '24']
connectable conductor cross-section for main contacts
product component removable terminal for main circuitNo
Number of contacts as normally open contact (EF008256)-
installation altitude at height above sea level maximum2 000 m
Number of contacts as normally closed contact (EF008255)-
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
insulation voltage for overvoltage category III according to IEC 60664
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
AWG number as coded connectable conductor cross section for main contacts18 ... 8
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top