| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4047621003672 |
| UPC | 804766216138 |
| ETIM | 5 |
| IDEA | 4 |
| depth | 72.5 mm |
| width | 6.2 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 93 mm |
| ● solid | 1x (0.25 ... 2.5 mm²) |
| Group Code | R711 |
| wire length | |
| — upwards | 0 mm |
| ● at 24 V | 3 A |
| Metal Factor | None |
| — forwards | 0 mm |
| ● at 125 V | 0.2 A |
| ● at 250 V | 3 A |
| ● stranded | 20 ... 14 |
| Date5/14/2022 | Subject to change without notice© Copyright Siemens 2022 |
| ON-delay time | |
| Product Group | 4950 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| — backwards | 0 mm |
| — downwards | 0 mm |
| Commodity Code | 85364900 |
| OFF-delay time | 11 ms |
| Product family | SIRIUS 3RQ3 coupling relays, narrow design |
| last modified: | 5/6/2021 |
| Net Weight (kg) | 0,033 Kg |
| thermal current | 6 A; for derating see characteristics |
| type of voltage | DC |
| — at the side | 0 mm |
| ● rated value | 110 V |
| fastening method | snap-on mounting |
| product category | SIRIUS 3RQ3 coupling relays in slim design |
| required spacing | |
| shock resistance | |
| ● relay output | Yes |
| Country of origin | Tunisia |
| mounting position | any |
| product component | |
| ● at DC maximum | 6 ms |
| ● initial value | 0.7 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| switching behavior | monostable |
| ● during storage | -40 ... +85 °C |
| ● for live parts | |
| Packaging Dimension | 16,00 x 19,00 x 7,00 |
| Product Description | output coupler relay coupler, 1 change-over contact 110 V DC working range 0.7 to 1.25 x US width 6.2 mm spring-type terminal (push-in) thermal current 6 A (see derating characteristic) |
| ambient temperature | |
| display version LED | Yes |
| product designation | Coupling relays with relay output (not plug-in) |
| protection class IP | IP20 |
| vibration resistance | |
| ● during operation | -40 ... +70 °C |
| ● during transport | -40 ... +85 °C |
| ● full-scale value | 1.25 |
| consumed active power | 0.6 W |
| design of the product | Output coupling link |
| Minimum order quantity | 5 |
| conducted interference | |
| ● for grounded parts | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at AWG cables solid | 1 x (20 ... 14) |
| General Product Approval | EMC |
| product type designation | 3RQ3 |
| Declaration of Conformity | Test Certificates |
| type of switching contact | Changeover contact |
| ● semi-conductor output | No |
| Export Control Regulations | AL : N / ECCN : N |
| ● at AWG cables stranded | 1x (20 ... 14) |
| Standard lead time ex-works | 50 Day/Days |
| Surcharge for Raw Materials | None |
| operating frequency maximum | 72 000 1/h |
| Package size unit of measure | MM |
| UK Declaration of Conformity | |
| control supply voltage at DC | |
| Substance Prohibitance (Date) | 03/25/2015 |
| material of switching contacts | AgSnO2 |
| ● with side-by-side mounting | |
| product component plug-in socket | No |
| relative humidity during operation | 10 ... 95 % |
| connectable conductor cross-section | |
| product function removable terminal | No |
| surge voltage resistance rated value | 4 kV |
| Article Number (Market Facing Number) | 3RQ3018-2AN08-0AA0 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3 |
| ampacity of the output relay at DC-13 | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| design of the relay operating mechanism | poled |
| reference code according to IEC 81346-2 | K |
| display version as status display by LED | LED green |
| flammability class of enclosure material | UL94 V-0 |
| contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) |
| ● between control and auxiliary circuit | 300 V |
| property of the output short-circuit proof | No |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| number of CO contacts for auxiliary contacts | 1 |
| type of connectable conductor cross-sections | |
| ● finely stranded with core end processing | 1x (0.25 ... 1.5 mm²) |
| maximum permissible voltage for safe isolation | |
| ● finely stranded without core end processing | 1x (0.25 ... 2.5 mm²) |
| EMC emitted interference according to IEC 60947-1 | ambience A (industrial sector) |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| mechanical service life (switching cycles) typical | 10 000 000 |
| operational current of auxiliary contacts at AC-15 | |
| operational current of auxiliary contacts at DC-13 | |
| ● for railway applications according to EN 61373 | Category 1, Class B |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Region Specific PriceGroup / Headquarter Price Group | 41H / 41H |
| AWG number as coded connectable conductor cross section | |
| installation altitude at height above sea level maximum | 2 000 m |
| percental drop-out voltage related to the input voltage | 9.6 % |
| ampacity of the output relay at AC-15 at 250 V at 50/60 Hz | 3 A |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| operating range factor control supply voltage rated value at DC | |
| type of electrical connection for auxiliary and control circuit | spring-loaded terminals (push-in) |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| Compliance with the substance restrictions according to RoHS directive | Since: 25.03.2015 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| design of the fuse link for short-circuit protection of the auxiliary switch required | fuse gG: 4 A |
| insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value | 300 V |
| General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide