3RQ2000-1CW01 - 3RQ2000-1CW01 SIEMENS Coupling relay in industrial enclosure 3 hard gold-plated changeover contacts Wide vol..
In Stock Hot Product

3RQ2000-1CW01

3RQ2000-1CW01 SIEMENS Coupling relay in industrial enclosure 3 hard gold-plated changeover contacts Wide vol..

$0.00USD
4657 in stock
Key Specifications
:Confirmation
EAN:4047621050447
UPC:804766715129
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4047621050447
UPC804766715129
ETIM5
depth90 mm
otherRailway
width22.5 mm
eClass6
height100 mm
● at DC24 ... 240 V
● solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Group CodeR711
● at 24 V1 A
ConfirmationConfirmation
Date5/8/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLA------
● at 125 V0.2 A
● at 250 V0.1 A
● at 50 Hz24 ... 240 V
● at 60 Hz24 ... 240 V
● stranded12 ... 20
ON-delay time
Product Group4949
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
OFF-delay time100 ms
Product familySIRIUS 3RQ2 coupling relays with industrial enclosure
last modified:1/18/2021
Net Weight (kg)0,193 Kg
type of voltageAC/DC
Depth (EF000049)90.0
Width (EF000008)22.5
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
shock resistance
Country of originGermany
Height (EF000040)100.0
mounting positionany
● at AC maximum10 ms
● at DC maximum10 ms
● initial value0.7
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
switching behaviormonostable
● during storage-40 ... +80 °C
Packaging Dimension110,00 x 125,00 x 35,00
Product DescriptionCoupling relay in industrial enclosure 3 hard gold-plated changeover contacts Wide voltage range 24 V to 240 V AC/DC Screw terminals
ambient temperature
degree of pollution3
product designationCoupling relay in industrial enclosure
protection class IPIP20
vibration resistance
● during operation-40 ... +60 °C
● during transport-40 ... +80 °C
● full-scale value1.1
consumed active power5 W
conducted interference
Product Lifecycle (PLM)PM300:Active Product
● at 24 V at 50/60 Hz3 A
● at AWG cables solid1x (20 ... 12), 2x (20 ... 14)
General Product ApprovalEMC
control supply voltage 1
product type designation3RQ2
● at 110 V at 50/60 Hz3 A
● at 250 V at 50/60 Hz3 A
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
Nominal current (EF000001)-
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
Package size unit of measureMM
Substance Prohibitance (Date)05/31/2018
electromagnetic compatibilityIEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
type of electrical connectionscrew-type terminals
Drive, polarization (EF003355)Polarized
With LED indication (EF005950)-
control supply voltage 1 at AC
material of switching contactsAgNi + Au
● according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
Complete with socket (EF003359)false
● according to IEC 60068-2-2711g / 15 ms
product component plug-in socketNo
Type of switch contact (EF003358)-
With detachable clamps (EF003340)false
relative humidity during operation10 ... 95 %
connectable conductor cross-section
Degree of protection (IP) (EF005474)IP20
Drive, switching attitude (EF003356)Mono stable
surge voltage resistance rated value4 kV
Article Number (Market Facing Number)3RQ2000-1CW01
EMC immunity according to IEC 60947-1corresponds to degree of severity 3
Voltage type for actuating (EF008242)AC/DC
ampacity of the output relay at AC-15
ampacity of the output relay at DC-13
Type of electric connection (EF003961)Screw connection
WEEE (2012/19/EU) Take-Back ObligationYes
With forced-guided contacts (EF003357)false
design of the relay operating mechanismpoled
reference code according to IEC 81346-2K
contact reliability of auxiliary contactsone incorrect switching per 100 million (11 V, 2 mA)
tightening torque with screw-type terminals0.6 ... 0.8 N·m
● between auxiliary and auxiliary circuit300 V
● due to burst according to IEC 61000-4-42 kV
number of CO contacts for auxiliary contacts3
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
maximum permissible voltage for safe isolation
● finely stranded without core end processing0.5 mm²
Rated control supply voltage Us at DC (EF003980)['24', '240']
EMC emitted interference according to IEC 60947-1ambience A (industrial sector)
electrostatic discharge according to IEC 61000-4-24 kV contact discharging, 8 kV air discharging
mechanical service life (switching cycles) typical10 000 000
● for railway applications according to EN 61373Category 1, Class B
field-based interference according to IEC 61000-4-310 V/m
Number of contacts as change-over contact (EF008257)3
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Rated control supply voltage Us at AC 50HZ (EF003978)['24', '240']
Rated control supply voltage Us at AC 60HZ (EF003979)['24', '240']
Number of contacts as normally open contact (EF008256)0
AWG number as coded connectable conductor cross section
installation altitude at height above sea level maximum2 000 m
Number of contacts as normally closed contact (EF008255)0
● due to conductor-earth surge according to IEC 61000-4-52 kV (line to ground)
thermal current of the switching element with contacts maximum5 A
operating range factor control supply voltage rated value at DC
stripped length of the cable for auxiliary and control contacts10 mm
● due to conductor-conductor surge according to IEC 61000-4-51 kV (line to line)
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
● between control and auxiliary circuit according to IEC 60947-1300 V
Compliance with the substance restrictions according to RoHS directiveSince: 31.05.2018
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 6 A
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformityType Test Certificates/Test ReportotherRailwayConfirmationConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top