Key Specifications
:Confirmation
EAN:4047621010946
UPC:804766327605
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Confirmation
EAN4047621010946
UPC804766327605
ETIM5
IDEA4
depth90 mm
width22.5 mm
UNSPSC15
eClass6
height100 mm
● at DC24 ... 240 V
● solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Group CodeR711
— upwards0 mm
● at 24 V0.5 A
Metal FactorLAO-----
— forwards0 mm
● ON-delayYes
● at 125 V0.2 A
● at 240 V5 A
● at 250 V3 A
● at 50 Hz24 ... 240 V
● at 60 Hz24 ... 240 V
● stranded20 ... 14
Date5/10/2022Subject to change without notice© Copyright Siemens 2022
Product Group4952
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
recovery time250 ms
— backwards0 mm
— downwards0 mm
● OFF delayNo
Commodity Code85364900
Product familySIRIUS 3RP25 timing relays 17.5 mm and 22.5 mm
last modified:12/9/2021
Net Weight (kg)0,180 Kg
adjustable time0.05 s ... 100 h
thermal current5 A
— at the side0 mm
Depth (EF000049)90.0
Width (EF000008)22.5
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
product function
required spacing
● non-volatileNo
● relay outputYes
Country of originGermany
Height (EF000040)100.0
Marine / Shippingother
minimum ON period35 ms
mounting positionany
product component
tightening torque0.6 ... 0.8 N·m
● initial value0.7
● pulse delayedYes
● pulse-shapingYes
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
switching function
type of insulationBasic insulation
● during storage-40 ... +85 °C
● for live parts
Packaging Dimension111,00 x 129,00 x 40,00
Product DescriptionTiming relay, Multifunction 2 change-over contacts, 13 functions Positively driven Relay contacts 24...240 V AC/DC at 50/60 Hz AC 7 time ranges (0.05 s...100 h) with LED, Screw terminal
ambient temperature
degree of pollution3
inrush current peak
product designationtiming relay
protection class IPIP20
● during operation-25 ... +60 °C
● during transport-40 ... +85 °C
● full-scale value1.1
Time range (EF003384)['0.05', '360000.0']
design of the product13 functions, suitable for railway applications
number of CO contacts
number of NC contacts
number of NO contacts
● additive ON-delayYes
● delayed switching0
conducted interference
power loss [W] maximum2 W
power supply influence1% in the whole voltage range to the set runtime
● for grounded parts
● star-delta circuitNo
Product Lifecycle (PLM)PM300:Active Product
● at AWG cables solid1x (20 ... 12), 2x (20 ... 14)
General Product ApprovalEMC
control supply voltage 1
product type designation3RP25
relative repeat accuracy1 %; +/-
● passing make contactYes
Declaration of ConformityTest Certificates
● instantaneous contact0
● passing break contactYes
● semi-conductor outputNo
Export Control RegulationsAL : N / ECCN : N
Nominal current (EF000001)-
● at AWG cables stranded1x (20 ... 12), 2x (20 ... 14)
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
● OFF delay/instantaneousNo
Package size unit of measureMM
Substance Prohibitance (Date)04/21/2016
Function star-delta (EF003380)false
With plug-in socket (EF003360)true
category according to EN 954-1none
control supply voltage 1 at AC
material of switching contactsAgSnO2
● with side-by-side mounting
duration of inrush current peak
test voltage for isolation test2.5 kV
● pulse delayed/instantaneousNo
● pulse-shaping/instantaneousNo
Function pulse shaping (EF003403)true
control supply voltage frequency 150 ... 60 Hz
relative humidity during operation10 ... 95 %
● ON-delay/instantaneous contactNo
connectable conductor cross-section
● additive ON-delay/instantaneousNo
Remote operation possible (EF003361)false
With semiconductor output (EF003373)false
surge voltage resistance rated value4 000 V
● ON-delay/OFF-delay/instantaneousNo
Article Number (Market Facing Number)3RP2505-1RW30
EMC immunity according to IEC 61812-1corresponds to degree of severity 3
Suitable as remote control (EF003362)false
Voltage type for actuating (EF008242)AC/DC
Suitable for front mounting (EF001127)screw and snap-on mounting onto 35 mm standard mounting rail
Type of electric connection (EF003961)Screw connection
WEEE (2012/19/EU) Take-Back ObligationYes
switching function with control signal
● star-delta circuit with delay timeNo
reference code according to IEC 81346-2K
● passing break contact/instantaneousNo
influence of the surrounding temperature1% in the whole temperature range to the set runtime
Function delay-on energization (EF003374)true
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
product extension optional remote controlNo
product extension required remote controlNo
design of the control terminal non-floatingYes
● due to burst according to IEC 61000-4-42 kV network connection / 1 kV control connection
● flashing symmetrically with pulse startYes
Function delay on de-energization (EF003401)false
design of the thread of the connection screwM3
shock resistance according to IEC 60068-2-2711g / 15 ms
type of connectable conductor cross-sections
● finely stranded with core end processing1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
● flashing asymmetrically with pulse startNo
type of voltage of the control supply voltageAC/DC
switching capacity current with inductive load0.01 ... 3 A
● flashing symmetrically with interval startYes
● passing make contact/instantaneous contactNo
Pluggable on auxiliary contact block (EF006952)false
operating frequency with 3RT2 contactor maximum5 000 1/h
vibration resistance according to IEC 60068-2-610 ... 55 Hz / 0.35 mm
● flashing asymmetrically with interval startNo
Outputs, reversible delayed/undelayed (EF006988)false
Rated control supply voltage Us at DC (EF003980)['24', '240']
EMC emitted interference according to IEC 61812-1ambience A (industrial sector)
● retriggerable with deactivated control signalYes
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
mechanical service life (switching cycles) typical10 000 000
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
field-based interference according to IEC 61000-4-310 V/m
Function floating contact on energization (EF003378)true
Region Specific PriceGroup / Headquarter Price Group41H / 41H
contact rating of auxiliary contacts according to ULR300 / B300
● retrotriggerable with switched-on control signalYes
Rated control supply voltage Us at AC 50HZ (EF003978)['24', '240']
Rated control supply voltage Us at AC 60HZ (EF003979)['24', '240']
relative setting accuracy relating to full-scale value5 %; +/-
AWG number as coded connectable conductor cross section
Function floating contact on de-energization (EF003402)true
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Clock function, starting with pause, variable (EF003365)false
Clock function, starting with pulse, variable (EF003366)false
Suitable for DIN rail (top hat rail) mounting (EF007250)screw and snap-on mounting onto 35 mm standard mounting rail
switching function of interval relay with control signal
● at the relay outputs switchover delayed/without delayNo
● flashing symmetrically with pulse start/instantaneousNo
Number of outputs, delayed, change-over contact (EF006840)2
● due to conductor-earth surge according to IEC 61000-4-52 kV
Number of outputs, delayed, normally open contact (EF006839)0
Number of outputs, undelayed, change-over contact (EF006837)0
● flashing symmetrically with interval start/instantaneousNo
Function flashing, starting with pause, fixed time (EF003363)true
Function flashing, starting with pulse, fixed time (EF003364)true
Number of outputs, delayed, normally closed contact (EF006838)0
Number of outputs, undelayed, normally open contact (EF006836)0
operating range factor control supply voltage rated value at DC
type of electrical connection for auxiliary and control circuitscrew-type terminals
● due to conductor-conductor surge according to IEC 61000-4-51 kV
Number of outputs, undelayed, normally closed contact (EF006835)0
electrical endurance (switching cycles) at AC-15 at 230 V typical100 000
Compliance with the substance restrictions according to RoHS directiveSince: 21.04.2016
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
operating range factor control supply voltage rated value at AC at 50 Hz
operating range factor control supply voltage rated value at AC at 60 Hz
● retrotriggerable with deactivated control signal/instantaneous contactNo
● retrotriggerable with switched-on control signal/instantaneous contactNo
design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 4 A
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesMarine / ShippingUK Declaration of ConformitySpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top