| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4047621068312 |
| UPC | 804766971839 |
| ETIM | 5 |
| depth | 150 mm |
| width | 30 mm |
| eClass | 6 |
| height | 142 mm |
| Group Code | R711 |
| safe state | Load circuit open |
| trip class | CLASS OFF / 5 / 10 adjustable |
| ● upwards | 50 mm |
| Confirmation | |
| Metal Factor | LAO----- |
| Date5/11/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 3724 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● downwards | 50 mm |
| Commodity Code | 85371098 |
| OFF-delay time | 35 ... 50 ms |
| Product family | Starter kit: ET 200SP motor starters |
| last modified: | 10/22/2021 |
| Net Weight (kg) | 0,810 Kg |
| fastening method | pluggable in BaseUnit |
| minimum load [%] | 20 % |
| product category | Motor starter |
| product function | Reversing starter |
| shock resistance | 6g / 11 ms |
| ● direct start | Yes |
| Country of origin | Germany |
| Marine / Shipping | other |
| mounting position | Vertical, horizontal (observe derating) |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIMATIC |
| type of assignment | 1 |
| ● during storage | -40 ... +70 °C |
| Packaging Dimension | 220,00 x 330,00 x 50,00 |
| Product Description | ET 200SP MS starter kit including 3RK 1308 motor starter 0.9 - 3 A, reversing starter, BaseUnit with infeed 24 V and 500 V, EMC distance module (blank module 15 mm) |
| ambient temperature | |
| degree of pollution | 2 |
| product designation | Starter kit |
| overvoltage category | III |
| utilization category | |
| vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
| ● during operation | -25 ... +60 °C; For derating see manual |
| ● during transport | -40 ... +70 °C |
| ● reverse starting | Yes |
| protocol is supported | |
| ● PROFINET protocol | Yes |
| ● on-site operation | Yes |
| conducted interference | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● maximum permissible | 28.8 V |
| ● minimum permissible | 20.4 V |
| General Product Approval | EMC |
| number of digital inputs | 4 |
| product type designation | ET 200SP |
| — at 230 V rated value | 0.25 hp |
| ● PROFIBUS DP protocol | Yes |
| ● at 400 V rated value | 55 kA |
| ● at 500 V rated value | 55 kA |
| ● for 3-phase AC motor | |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| ● for main energy infeed | Plug contact to Base Unit |
| ● remote firmware update | Yes |
| Standard lead time ex-works | 5 Day/Days |
| Surcharge for Raw Materials | None |
| Package size unit of measure | MM |
| type of the motor protection | solid-state |
| — at 200/208 V rated value | 0.5 hp |
| — at 220/230 V rated value | 0.5 hp |
| — at 460/480 V rated value | 1.5 hp |
| Substance Prohibitance (Date) | 03/13/2019 |
| operating voltage rated value | 48 ... 500 V |
| type of electrical connection | |
| ● for single-phase AC motor | |
| insulation voltage rated value | 500 V |
| ● according to IEC 60947-4-2 | AC-53a: 3 A: (8-0,7: 70-32) |
| design of the switching contact | Hybrid |
| ● 1 for digital input signals | Pluggable module - accessory |
| ● intrinsic device protection | Yes |
| supply voltage at DC rated value | 24 V |
| ● for supply voltage line-side | Plug contact to Base Unit |
| operating frequency 1 rated value | 50 Hz |
| operating frequency 2 rated value | 60 Hz |
| ● for load-side outgoing feeder | Plug contact to Base Unit |
| ● supports PROFIenergy shutdown | Yes |
| air pressure according to SN 31205 | 900 ... 1 060 hPa |
| design of short-circuit protection | fuse |
| product function bus communication | Yes |
| relative humidity during operation | 10 ... 95 % |
| supply voltage 1 at DC rated value | |
| yielded mechanical performance [hp] | |
| product component motor brake output | No |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3RK1908-1SK00 |
| EMC immunity according to IEC 60947-1 | Class A |
| type of voltage of the supply voltage | DC |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● between main and auxiliary circuit | 500 V |
| duration of inrush current peak at 24 V | 0.145 ms |
| reference code according to IEC 81346-2 | Q |
| number of poles for main current circuit | 3 |
| wire length for motor unshielded maximum | 200 m |
| ● supports PROFIenergy measured values | Yes |
| product function short circuit protection | Yes |
| protocol is supported AS-Interface protocol | No |
| required spacing with side-by-side mounting | |
| ● due to burst according to IEC 61000-4-4 | 2 kV |
| equipment variant according to IEC 60947-4-2 | 3 |
| maximum permissible voltage for safe isolation | |
| operational current at AC at 400 V rated value | 3 A |
| ● at 500 V according to UL 60947 rated value | 100 kA |
| ● for power supply reverse polarity protection | Yes |
| EMC emitted interference according to IEC 60947-1 | class A |
| electrostatic discharge according to IEC 61000-4-2 | 8 kV air discharge |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| operating power for 3-phase motors at 400 V at 50 Hz | 0.37 ... 1.1 kW |
| touch protection on the front according to IEC 60529 | finger-safe |
| breaking capacity maximum short-circuit current (Icu) | |
| relative negative tolerance of the operating frequency | 5 % |
| relative positive tolerance of the operating frequency | 5 % |
| installation altitude at height above sea level maximum | 4 000 m; For derating see manual |
| protection class IP on the front according to IEC 60529 | IP20 |
| conducted HF interference emissions according to CISPR11 | Class A for industrial environment |
| field-bound HF interference emission according to CISPR11 | Class A for industrial environment |
| relative symmetrical tolerance of the operating frequency | 5 % |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| type of electrical connection of the communication interface | Plug contact to Base Unit |
| environmental category during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices) |
| ● due to high-frequency radiation according to IEC 61000-4-6 | Class A |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| full-load current (FLA) for 3-phase AC motor at 480 V rated value | 3 A |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 480 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 13.03.2019 |
| mechanical service life (switching cycles) of the main contacts typical | 30 000 000 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| adjustable current response value current of the current-dependent overload release | 0.9 ... 3 A |
| General Product ApprovalEMCDeclaration of ConformityMarine / ShippingConfirmationMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide