| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4047621021102 |
| UPC | 804766246999 |
| ETIM | 5 |
| depth | 60 mm |
| width | 30 mm |
| eClass | 6 |
| height | 135 mm |
| Group Code | R711 |
| Metal Factor | None |
| Date5/13/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 3724 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85389099 |
| Product family | ET 200SP motor starters |
| last modified: | 1/7/2021 |
| Net Weight (kg) | 0,070 Kg |
| Depth (EF000049) | - |
| Width (EF000008) | - |
| fastening method | pluggable on BaseUnit |
| product category | Accessories |
| product function | Zubehör |
| shock resistance | 6g / 11 ms |
| Country of origin | Czech Republic |
| Height (EF000040) | - |
| Test Certificates | Marine / Shipping |
| mounting position | vertical, horizontal, flat |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| ● during storage | -40 ... +70 °C |
| Packaging Dimension | 95,00 x 161,00 x 45,00 |
| Product Description | BU cover 30 mm for ET 200SP motor starter for protection of empty slots |
| ambient temperature | |
| degree of pollution | 2 |
| product designation | Base Unit cover 30 mm |
| With fuse (EF006693) | - |
| vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
| ● during operation | -25 ... +60 °C |
| ● during transport | -40 ... +70 °C |
| design of the product | for protection of empty slots, 30 mm |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | EMC |
| Release class (EF006668) | - |
| product type designation | BaseUnit cover |
| Export Control Regulations | AL : N / ECCN : N |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | - |
| Package size unit of measure | MM |
| Substance Prohibitance (Date) | 04/15/2016 |
| Type of motor starter (EF009598) | - |
| Rail mounting possible (EF003972) | - |
| External reset possible (EF003426) | - |
| Type Test Certificates/Test Report | |
| Degree of protection (IP) (EF005474) | - |
| Article Number (Market Facing Number) | 3RK1908-1CA00-0BP0 |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | - |
| Voltage type for actuating (EF008242) | - |
| With short-circuit release (EF006691) | - |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | - |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | - |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| Rated control supply voltage Us at DC (EF003980) | - |
| Rated operation current at AC-3, 400 V (EF009602) | - |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| Supporting protocol for other bus systems (EF003062) | - |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| Coordination class according to IEC 60947-4-3 (EF012390) | - |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | - |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| Number of auxiliary contacts as normally open contact (EF001376) | - |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| Number of auxiliary contacts as normally closed contact (EF001377) | - |
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - |
| General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherType Test Certificates/Test ReportConfirmation | General Product Approval |
Technical specifications and performance data