Service time: Monday to Friday 9:00-18:00
3RK1908-1AA00-0BP0 - 3RK1908-1AA00-0BP0 SIEMENS 3DI/LC module (connection terminals) for ET 200SP motor starter
In Stock Hot Product

3RK1908-1AA00-0BP0

3RK1908-1AA00-0BP0 SIEMENS 3DI/LC module (connection terminals) for ET 200SP motor starter

$0.00USD
3916 in stock
Key Specifications
:
EAN:4047621012209
UPC:804766246982
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4047621012209
UPC804766246982
ETIM5
depth42.3 mm
width30 mm
eClass6
height54.5 mm
● noteGreen LED
Group CodeR711
Metal FactorNone
Date5/12/2022Subject to change without notice© Copyright Siemens 2022
Product Group3724
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85371098
Product familyET 200SP motor starters
last modified:1/6/2021
Net Weight (kg)0,047 Kg
Depth (EF000049)42.3
Width (EF000008)30.0
fastening methodCan be plugged onto motor starters
product categoryAccessories
product function
shock resistance6g / 11 ms
Country of originGermany
Height (EF000040)54.5
Test CertificatesMarine / Shipping
mounting positionvertical, horizontal, flat
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIMATIC
● during storage-40 ... +70 °C
Packaging Dimension60,00 x 77,00 x 50,00
Product Description3DI/LC module (connection terminals) for ET 200SP motor starter
ambient temperature
degree of pollution2
product designation3DI/LC control module
protection class IPIP20
With fuse (EF006693)-
vibration resistance15 mm to 6 Hz; 2g to 500 Hz
● during operation-25 ... +60 °C
● during transport-40 ... +70 °C
● product functionAccessories
design of the productAccessories
● solid or stranded0.2 ... 1.5 mm²
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Release class (EF006668)-
number of digital inputs4
product type designationET 200SP
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works1 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
size of the screwdriver tipStandard screwdriver 0.6 mm x 3.5 mm
Package size unit of measureMM
shape of the screwdriver tipSlot
Substance Prohibitance (Date)04/15/2016
wire length of sensor maximum30 m
Type of motor starter (EF009598)Other
Rail mounting possible (EF003972)-
External reset possible (EF003426)-
Type Test Certificates/Test Report
air pressure according to SN 31205900 ... 1 060 hPa
relative humidity during operation10 ... 95 %
● digital inputs parameterizableYes
Degree of protection (IP) (EF005474)IP20
Article Number (Market Facing Number)3RK1908-1AA00-0BP0
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)-
Voltage type for actuating (EF008242)-
With short-circuit release (EF006691)true
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
input delay time at the standard inputs
output voltage for sensor supply minimum19.2 V
type of output voltage for sensor supplyDC
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)-
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
diagnostics function short-circuit detectionYes
● finely stranded with core end processing0.25 ... 1.5 mm²
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
digital input version type 1 acc. to IEC 61131Yes
Rated operation power at AC-3, 400 V (EF001364)-
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
● finely stranded without core end processing0.2 ... 1.5 mm²
Rated control supply voltage Us at DC (EF003980)-
● for signal <0> to <1> at rated input voltage10 ... 15 ms
● for signal <1> to <0> at rated input voltage10 ... 15 ms
Rated operation current at AC-3, 400 V (EF009602)-
Supporting protocol for INTERBUS-Safety (EF006662)-
output current for sensor supply at 60 °C maximum0.1 A
Supporting protocol for DeviceNet Safety (EF007520)-
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Supporting protocol for other bus systems (EF003062)-
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
input current at digital input for signal <1> typical9 mA
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
installation altitude at height above sea level maximum2 000 m
Coordination class according to IEC 60947-4-3 (EF012390)-
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)-
connectable conductor cross-section for auxiliary contacts
Supporting protocol for AS-Interface Safety at Work (EF007519)-
type of electrical connection for auxiliary and control circuitspring-loaded terminals (push-in)
Number of auxiliary contacts as normally open contact (EF001376)-
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
Number of auxiliary contacts as normally closed contact (EF001377)-
● product function with 24 V sensor supply short-circuit protectionYes
Compliance with the substance restrictions according to RoHS directiveSince: 15.04.2016
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
value range of the input voltage at digital input for signal <0> detection-30 ... +5 V
value range of the input voltage at digital input for signal <1> detection+15 ... +30 V
AWG number as coded connectable conductor cross section for auxiliary contacts24 ... 16
● at the standard inputs at rated input voltage parameterizable input delay timeNo
Type of electrical connection for auxiliary- and control current circuit (EF006979)Other
display version for diagnostic function: Status display transmission channel channel status LEDYes
General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherType Test Certificates/Test ReportConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty