| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4047621021348 |
| UPC | 804766246975 |
| ETIM | 5 |
| depth | 75 mm |
| width | 30 mm |
| eClass | 6 |
| height | 215 mm |
| ● solid | 1x 0,5 ... 2,5 mm² |
| Group Code | R711 |
| ● upwards | 50 mm |
| Metal Factor | None |
| Date5/11/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 3724 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| ● downwards | 50 mm |
| Commodity Code | 85369095 |
| Product family | ET 200SP motor starters |
| last modified: | 12/16/2020 |
| Net Weight (kg) | 0,170 Kg |
| Depth (EF000049) | 75.0 |
| Width (EF000008) | 30.0 |
| ampacity maximum | 7 A |
| fastening method | standard rail |
| product category | Accessories |
| shock resistance | 6g / 11 ms |
| Country of origin | Czech Republic |
| Height (EF000040) | 215.0 |
| Test Certificates | Marine / Shipping |
| mounting position | vertical, horizontal |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIMATIC |
| ● during storage | -40 ... +70 °C |
| Packaging Dimension | 55,00 x 219,00 x 86,00 |
| Product Description | Base unit (BU30-MS4) For ET 200SP motor starter Without infeed |
| ambient temperature | |
| degree of pollution | 2 |
| product designation | BaseUnit |
| With fuse (EF006693) | - |
| vibration resistance | 15 mm to 6 Hz; 2g to 500 Hz |
| ● during operation | -25 ... +60 °C; For derating see manual |
| ● during transport | -40 ... +70 °C |
| design of the product | Without feed in |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● maximum permissible | 28.8 V |
| ● minimum permissible | 20.4 V |
| General Product Approval | EMC |
| Release class (EF006668) | - |
| number of digital inputs | 0 |
| product type designation | ET 200SP |
| Export Control Regulations | AL : N / ECCN : N |
| Standard lead time ex-works | 60 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| size of the screwdriver tip | Standard screwdriver 0.6 mm x 3.5 mm |
| type of connecting terminal | Push-in terminal |
| Package size unit of measure | MM |
| shape of the screwdriver tip | Slot |
| ● for main current circuit | spring-loaded terminals (push-in) |
| Substance Prohibitance (Date) | 04/15/2016 |
| operating voltage rated value | 500 V |
| type of electrical connection | |
| insulation voltage rated value | 500 V |
| Type of motor starter (EF009598) | Other |
| Rail mounting possible (EF003972) | - |
| External reset possible (EF003426) | - |
| Type Test Certificates/Test Report | |
| air pressure according to SN 31205 | 900 ... 1 060 hPa |
| relative humidity during operation | 10 ... 95 % |
| supply voltage 1 at DC rated value | 24 V |
| Degree of protection (IP) (EF005474) | IP20 |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3RK1908-0AP00-0DP0 |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | 32 |
| Voltage type for actuating (EF008242) | DC |
| With short-circuit release (EF006691) | - |
| type of voltage of the supply voltage | DC |
| ● for auxiliary and control circuit | spring-loaded terminals (push-in) |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | - |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● between main and auxiliary circuit | 500 V |
| reference code according to IEC 81346-2 | Q |
| number of poles for main current circuit | 3 |
| type of voltage of the operating voltage | AC |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | - |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| required spacing with side-by-side mounting | |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| ● finely stranded with core end processing | 1x 0,5 ... 2,5 mm² |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| maximum permissible voltage for safe isolation | |
| operational current at AC at 400 V rated value | 32 A; Derating, see Manual |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| ● finely stranded without core end processing | 1x 0,5 ... 2,5 mm² |
| Rated control supply voltage Us at DC (EF003980) | - |
| Rated operation current at AC-3, 400 V (EF009602) | - |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| Supporting protocol for other bus systems (EF003062) | - |
| touch protection on the front according to IEC 60529 | finger-safe |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| installation altitude at height above sea level maximum | 4 000 m; For derating see manual |
| protection class IP on the front according to IEC 60529 | IP20 |
| Coordination class according to IEC 60947-4-3 (EF012390) | - |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Other |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| environmental category during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices) |
| Number of auxiliary contacts as normally open contact (EF001376) | - |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| Number of auxiliary contacts as normally closed contact (EF001377) | - |
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| type of connectable conductor cross-sections for load-side outgoing feeder | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other |
| type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder | 1x 20 ... 12 |
| General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesMarine / ShippingotherType Test Certificates/Test ReportConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide