| Parameter | Value |
|---|---|
| EAN | 4011209437883 |
| UPC | 662643247541 |
| ETIM | 5 |
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. |
| depth | 95 mm |
| width | 15 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 196.5 mm |
| ● at DC | 24 ... 24 V |
| Group Code | R711 |
| Date5/8/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| Product Group | 4962 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85371098 |
| Product family | Accessories |
| last modified: | 12/15/2020 |
| Net Weight (kg) | 0,103 Kg |
| product feature | |
| fastening method | pluggable on terminal module |
| product function | |
| shock resistance | 5g / 11 ms |
| Country of origin | Germany |
| mounting position | vertical, horizontal |
| LKZ_FDB/ CatalogID | CC-IC10 |
| PLM Effective Date | Product phase-out since: 01.10.2020 |
| Packaging Quantity | 1 |
| product brand name | SIMATIC |
| ● during storage | -40 ... +70 °C |
| Packaging Dimension | 28,00 x 108,50 x 147,00 |
| Product Description | XB1 for ET 200S/DS-X/RS-X brake control module 24 V DC 4 A for motors with mechanical brakes |
| ambient temperature | |
| vibration resistance | 2g |
| ● during operation | 0 ... 60 °C |
| ● during transport | -40 ... +70 °C |
| conducted interference | |
| supply voltage 1 at DC | 24 ... 24 V |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| ● maximum permissible | 28.8 V |
| ● minimum permissible | 20.4 V |
| General Product Approval | EMC |
| control supply voltage 1 | |
| number of digital inputs | 0 |
| product type designation | ET 200S |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| ● for main energy infeed | screw-type terminals |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| operating frequency maximum | 750 1/h |
| Package size unit of measure | MM |
| Substance Prohibitance (Date) | 03/01/2017 |
| operating voltage rated value | 24 ... 24 V |
| type of electrical connection | |
| ● brake control with 24 V DC | Yes |
| ● brake control with 180 V DC | No |
| ● brake control with 230 V AC | No |
| ● brake control with 500 V DC | No |
| ● for main energy transmission | via energy bus |
| ● for supply voltage line-side | via backplane bus |
| ● for load-side outgoing feeder | Screw-type terminals |
| ● supports PROFIenergy shutdown | No |
| relative humidity during operation | 5 ... 95 % |
| supply voltage 1 at DC rated value | |
| ● digital inputs parameterizable | No |
| ● for communication transmission | via backplane bus |
| ● of the communication interface | via backplane bus |
| ● digital outputs parameterizable | No |
| ● for supply voltage transmission | via backplane bus |
| surge voltage resistance rated value | 8 kV |
| Article Number (Market Facing Number) | 3RK1903-0CB00 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
| type of voltage of the supply voltage | DC |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Type of accessory/spare part (EF000215) | - |
| number of poles for main current circuit | 2 |
| ● supports PROFIenergy measured values | No |
| type of voltage of the control supply voltage | DC |
| EMC emitted interference according to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| touch protection on the front according to IEC 60529 | finger-safe |
| installation altitude at height above sea level maximum | 2 000 m |
| protection class IP on the front according to IEC 60529 | IP20 |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV (U > 24 V DC) |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV (U > 24 V DC) |
| operating range relative to the operating voltage at AC at 50 Hz | 200 ... 440 V |
| type of voltage of the supply voltage for brake control required | DC |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 600 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2017 |
| T1 value for proof test interval or service life according to IEC 61508 | 20 y |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmation | General Product Approval |