| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209672796 |
| UPC | 754554952437 |
| ETIM | 5 |
| IDEA | 4 |
| Type | 4 inputs / 4 outputs (virtual) |
| note | the module requires an address in each of the two AS-i networks |
| depth | 29 mm |
| width | 60 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 152 mm |
| Outputs | |
| Addressing | front addressing socket |
| Group Code | R711 |
| ● socket | not assigned (closed) |
| ID/ID2 code | F/F |
| Date5/9/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| ● socket 2 | not assigned (closed) |
| ● socket 3 | not assigned (closed) |
| ● socket 4 | not assigned (closed) |
| ● socket 5 | not assigned (closed) |
| ● socket 6 | not assigned (closed) |
| ● socket 7 | not assigned (closed) |
| ● socket 8 | not assigned (closed) |
| ● watchdog | not required |
| Delivery note | the modules are delivered without mounting plate |
| Input circuit | PNP transistor |
| Product Group | 3720 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85371098 |
| Product family | Digital I/O modules, IP67 - K60 |
| Status display | |
| last modified: | 3/10/2021 |
| Ground terminal | not required |
| Net Weight (kg) | 0,181 Kg |
| Depth (EF000049) | 29.0 |
| Width (EF000008) | 60.0 |
| fastening method | standard rail mounting/wall mounting using mounting plate for K60 compact module |
| shock resistance | 15g / 11 ms |
| Country of origin | Czech Republic |
| Height (EF000040) | 152.0 |
| I/O configuration | 7 |
| Marine / Shipping | other |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Number I/O sockets | 0 |
| Packaging Quantity | 1 |
| ● during storage | -40 ... +85 °C |
| Packaging Dimension | 78,00 x 164,00 x 48,00 |
| Product Description | AS-i data coupler K60 digital 4 DI/4 DQ, virtual, IP67 module occupies 2 addresses Mounting plate 3RK1901-0CA00 must be ordered separately |
| ambient temperature | |
| protection class IP | IP67 |
| ● display of I/Os | yellow LED |
| ● during operation | -25 ... +85 °C |
| design of the product | AS-Interface data coupler |
| Assignment of data bits | |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | EMC |
| design of the slave type | standard slave |
| number of digital inputs | 4 |
| IO link master (EF007298) | false |
| Output current (EF003202) | - |
| number of digital outputs | 4 |
| Export Control Regulations | AL : N / ECCN : N |
| Standard lead time ex-works | 80 Day/Days |
| Surcharge for Raw Materials | None |
| System accessory (EF004118) | true |
| Package size unit of measure | MM |
| Supply voltage DC (EF007534) | ['-', '-'] |
| Radio standard GSM (EF008524) | false |
| Radio standard GPRS (EF008523) | false |
| Radio standard UMTS (EF008525) | false |
| Rack-assembly possible (EF007018) | false |
| Rail mounting possible (EF003972) | FALSE |
| Type of digital output (EF003601) | None |
| Type of output voltage (EF008222) | #NO_DATA# / DC |
| With optical interface (EF003028) | false |
| Front build in possible (EF007016) | false |
| Supply voltage AC 50 Hz (EF007532) | ['-', '-'] |
| Supply voltage AC 60 Hz (EF007533) | ['-', '-'] |
| Number of digital inputs (EF001992) | 4 |
| Radio standard Bluetooth (EF007178) | false |
| AS interface total current input max | 70 mA |
| Degree of protection (IP) (EF005474) | IP67 |
| Input current at signal 1 (EF001428) | - |
| Number of digital outputs (EF001993) | 4 |
| Article Number (Market Facing Number) | 3RK1408-8SQ00-0AA3 |
| Outputs external power supply 24 V DC | not required |
| Permitted voltage at input (EF007554) | ['-', '-'] |
| Radio standard WLAN 802.11 (EF007179) | false |
| SIL according to IEC 61508 (EF009889) | - |
| Digital inputs configurable (EF008516) | FALSE |
| Number of HW-interfaces USB (EF003025) | 0 |
| Permitted voltage at output (EF007553) | ['-', '-'] |
| Supporting protocol for ASI (EF003051) | true |
| Supporting protocol for CAN (EF003053) | false |
| Supporting protocol for KNX (EF003055) | false |
| Supporting protocol for LON (EF003017) | false |
| Type of electric connection (EF003961) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| Digital outputs configurable (EF008520) | false |
| ● display of AS-Interface/diagnostics | green/red LED |
| Number of HW-interfaces other (EF003027) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Suitable for safety functions (EF001597) | false |
| Time delay at signal exchange (EF002382) | ['-', '-'] |
| Wall mounting/direct mounting (EF007020) | FALSE |
| Category according to EN 954-1 (EF006782) | - |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Supporting protocol for Modbus (EF003057) | false |
| Supporting protocol for SERCOS (EF006657) | false |
| Supporting protocol for TCP/IP (EF003050) | false |
| Voltage type of supply voltage (EF002991) | DC |
| Supporting protocol for SUCONET (EF003060) | false |
| Type of voltage (input voltage) (EF003033) | #NO_DATA# / DC |
| Number of HW-interfaces Wireless (EF006933) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Supporting protocol for INTERBUS (EF003054) | false |
| Supporting protocol for PROFIBUS (EF003052) | false |
| Appendant operation agent (Ex ia) (EF004141) | - |
| Appendant operation agent (Ex ib) (EF004142) | - |
| Explosion safety category for gas (EF003997) | None |
| Supporting protocol for DeviceNet (EF003059) | false |
| Supporting protocol for PROFIsafe (EF007526) | false |
| Explosion safety category for dust (EF003998) | None |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Supporting protocol for EtherNet/IP (EF007521) | false |
| Supporting protocol for PROFINET IO (EF007525) | false |
| Supporting protocol for SafetyBUS p (EF007527) | false |
| Supporting protocol for Data-Highway (EF003058) | false |
| Supporting protocol for PROFINET CBA (EF007524) | false |
| Supporting protocol for INTERBUS-Safety (EF006662) | false |
| Supporting protocol for DeviceNet Safety (EF007520) | false |
| Region Specific PriceGroup / Headquarter Price Group | 42C / 42C |
| Supporting protocol for other bus systems (EF003062) | false |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Short-circuit protection, outputs available (EF003203) | - |
| Supporting protocol for Foundation Fieldbus (EF007522) | false |
| Performance level according to EN ISO 13849-1 (EF007399) | - |
| operating voltage according to AS-Interface spezification | 26.5 ... 31.6 V |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false |
| Fieldbus connection over separate bus coupler possible (EF004002) | - |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| General Product ApprovalEMCDeclaration of ConformityConfirmationMarine / ShippingMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide