| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209824263 |
| UPC | 662643544732 |
| ETIM | 5 |
| depth | 148 mm |
| width | 294 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 215 mm |
| ● at DC | 20.4 ... 28.8 V |
| Group Code | R711 |
| trip class | CLASS 5, 10, 15, 20 |
| ● at AC-3 | |
| Metal Factor | LAO----- |
| Date5/12/2022 | Subject to change without notice© Copyright Siemens 2022 |
| ON-delay time | 85 ms |
| Product Group | 3722 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85371098 |
| OFF-delay time | 65 ms |
| Product family | M200D motor starter modules |
| last modified: | 12/21/2021 |
| Net Weight (kg) | 4,000 Kg |
| operating power | |
| product feature | |
| ● recommended | horizontal |
| Depth (EF000049) | 148.0 |
| Width (EF000008) | 294.0 |
| fastening method | screw fixing |
| product function | |
| shock resistance | 12g / 11 ms |
| ● direct start | No |
| Country of origin | Germany |
| Height (EF000040) | 215.0 |
| mounting position | vertical, horizontal, flat |
| number of sockets | |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIRIUS |
| type of assignment | 1 |
| ● during storage | -40 ... +70 °C |
| Packaging Dimension | 287,00 x 377,00 x 221,00 |
| Product Description | SIRIUS motor starter M200D Technology module Reversing starter Mechanical switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch via communication module 3RK1305* can be used on PROFIBUS or PROFINET |
| ambient temperature | |
| degree of pollution | 3 |
| operational current | |
| product designation | Motor starters |
| protection class IP | IP65 |
| With fuse (EF006693) | - |
| vibration resistance | 7 mm / 2g |
| ● during operation | 0.6 A |
| ● during transport | -40 ... +70 °C |
| ● reverse starting | Yes |
| control current at DC | |
| design of the product | reversing starter |
| protocol is supported | |
| ● PROFINET protocol | No |
| ● at DC rated value | 20.4 ... 28.8 V |
| ● on-site operation | Yes |
| conducted interference | |
| Product Lifecycle (PLM) | PM300:Active Product |
| design of the interface | |
| General Product Approval | EMC |
| Release class (EF006668) | Other |
| control supply voltage 1 | |
| number of digital inputs | 4 |
| product type designation | M200D |
| — at 400 V rated value | 5.5 kW |
| — at 500 V rated value | 5 500 W |
| ● PROFIBUS DP protocol | No |
| ● at 400 V rated value | 50 000 A |
| ● at 500 V rated value | 50 000 A |
| ● for 3-phase AC motor | |
| Declaration of Conformity | Test Certificates |
| number of digital outputs | 2 |
| ● AS-Interface protocol | No |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| certificate of suitability | CE |
| Standard lead time ex-works | 15 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| Package size unit of measure | MM |
| type of the motor protection | full motor protection |
| — at 220/230 V rated value | 3 hp |
| — at 460/480 V rated value | 7.5 hp |
| — at 575/600 V rated value | 10 hp |
| ● for main current circuit | plug according to ISO 23570, HAN Q4/2 |
| Substance Prohibitance (Date) | 07/01/2006 |
| operating voltage rated value | 200 ... 440 V |
| type of electrical connection | |
| ● for digital input signals | 4 |
| insulation voltage rated value | 500 V |
| ● at AC at 400 V rated value | 12 A |
| ● brake control with 24 V DC | No |
| ● for digital output signals | 2 |
| design of the switching contact | electromechanical |
| ● 1 for digital input signals | M12 socket |
| ● 2 for digital input signals | M12 socket |
| ● 3 for digital input signals | M12 socket |
| ● 4 for digital input signals | M12 socket |
| ● brake control with 180 V DC | No |
| ● brake control with 230 V AC | Yes |
| ● brake control with 400 V AC | Yes |
| ● brake control with 500 V DC | No |
| Type of motor starter (EF009598) | Reversing starter |
| ● 1 for digital output signals | M12 socket |
| ● at AC-3 at 400 V rated value | 12 A |
| ● in standby mode of operation | 0.1 A |
| Rail mounting possible (EF003972) | - |
| External reset possible (EF003426) | - |
| design of short-circuit protection | circuit-breakers |
| product function bus communication | Yes |
| relative humidity during operation | 10 ... 95 % |
| ● digital inputs parameterizable | Yes |
| yielded mechanical performance [hp] | |
| ● digital outputs parameterizable | Yes |
| Degree of protection (IP) (EF005474) | IP65 |
| product component motor brake output | Yes |
| surge voltage resistance rated value | 6 000 V |
| Article Number (Market Facing Number) | 3RK1395-6LS41-3AD3 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | 12 |
| Voltage type for actuating (EF008242) | DC |
| With short-circuit release (EF006691) | true |
| type of voltage of the supply voltage | DC |
| ● for auxiliary and control circuit | connector |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● between main and auxiliary circuit | 400 V |
| number of poles for main current circuit | 3 |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| product function short circuit protection | Yes |
| touch protection against electrical shock | finger-safe |
| ● between control and auxiliary circuit | 24 V |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | ['1.5', '12'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| protocol is supported AS-Interface protocol | No |
| ● due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| type of voltage of the control supply voltage | DC |
| ● in switching state ON with bypass circuit | 5.04 W |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| maximum permissible voltage for safe isolation | |
| ● in switching state OFF with bypass circuit | 1.9584 W |
| Rated operation power at AC-3, 400 V (EF001364) | 5.5 |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| power loss [W] in auxiliary and control circuit | |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] |
| ● control circuit interface to parallel wiring | No |
| EMC emitted interference according to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
| Rated operation current at AC-3, 400 V (EF009602) | 12 |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| product extension braking module for brake control | No |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| Supporting protocol for other bus systems (EF003062) | - |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] |
| breaking capacity maximum short-circuit current (Icu) | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| installation altitude at height above sea level maximum | 2 000 m |
| product function control circuit interface with IO link | No |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Other |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
| Number of auxiliary contacts as normally open contact (EF001376) | - |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| full-load current (FLA) for 3-phase AC motor at 480 V rated value | 11 A |
| Number of auxiliary contacts as normally closed contact (EF001377) | - |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 600 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| mechanical service life (switching cycles) of the main contacts typical | 10 000 000 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other |
| adjustable current response value current of the current-dependent overload release | 1.5 ... 12 A |
| General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherDangerous GoodUK Declaration of ConformityType Test Certificates/Test ReportConfirmationTransport Information | General Product Approval |
Technical specifications and performance data
Installation and operation guide