Key Specifications
:
EAN:4011209823860
UPC:662643544350
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209823860
UPC662643544350
ETIM5
depth159 mm
width294 mm
UNSPSC14
eClass6
height215 mm
● at DC20.4 ... 28.8 V
Group CodeR711
trip classCLASS 5, 10, 15, 20
● at AC-3
Date5/9/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
ON-delay time25 ms
Product Group3722
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85371098
OFF-delay time35 ms
Product familyM200D Standard motor starters
last modified:12/21/2021
Net Weight (kg)4,446 Kg
operating power
product feature
● recommendedhorizontal
Depth (EF000049)159.0
Width (EF000008)294.0
fastening methodscrew fixing
product function
shock resistance12g / 11 ms
● direct startNo
Country of originGermany
Height (EF000040)215.0
mounting positionvertical, horizontal, flat
number of sockets
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
type of assignment1
● during storage-40 ... +70 °C
Packaging Dimension287,00 x 377,00 x 221,00
Product DescriptionSIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter standard Electronic switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0
ambient temperature
degree of pollution3
operational current
product designationMotor starters
protection class IPIP65
With fuse (EF006693)-
vibration resistance7 mm / 2g
● during operation0.6 A
● during transport-40 ... +70 °C
● reverse startingYes
control current at DC
design of the productreversing starter
protocol is supported
● PROFINET protocolNo
● at DC rated value24 V
● on-site operationNo
conducted interference
supply voltage 1 at DC24 V
Product Lifecycle (PLM)PM300:Active Product
design of the interface
● maximum permissible31.6 V
● minimum permissible26.5 V
General Product ApprovalEMC
Release class (EF006668)Other
control supply voltage 1
number of digital inputs4
product type designationM200D
— at 400 V rated value5.5 kW
— at 500 V rated value5 500 W
● PROFIBUS DP protocolNo
● at 400 V rated value50 000 A
● at 500 V rated value20 000 A
● for 3-phase AC motor
Declaration of ConformityTest Certificates
number of digital outputs1
● AS-Interface protocolYes
● for device addressingM12 plug
Export Control RegulationsAL : N / ECCN : EAR99
certificate of suitabilityCE
Standard lead time ex-worksOn request
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
Package size unit of measureMM
UK Declaration of Conformity
type of the motor protectionfull motor protection
— at 220/230 V rated value3 hp
— at 460/480 V rated value7.5 hp
● for main current circuitplug according to ISO 23570, HAN Q4/2
Substance Prohibitance (Date)07/01/2006
operating voltage rated value200 ... 440 V
type of electrical connection
● for digital input signals4
insulation voltage rated value500 V
● at AC at 400 V rated value12 A
● brake control with 24 V DCNo
● for digital output signals1
design of the switching contactsolid-state / thyristor / 2 phases
● 1 for digital input signalsM12 socket
● 2 for digital input signalsM12 socket
● 3 for digital input signalsM12 socket
● 4 for digital input signalsM12 socket
● brake control with 180 V DCNo
● brake control with 230 V ACNo
● brake control with 400 V ACNo
● brake control with 500 V DCNo
Type of motor starter (EF009598)Reversing starter
● 1 for digital output signalsM12 socket
● at AC-3 at 400 V rated value12 A
● for supply voltage line-sideM12 plug
● in standby mode of operation0.1 A
Rail mounting possible (EF003972)-
External reset possible (EF003426)-
design of short-circuit protectioncircuit-breakers
product function bus communicationYes
relative humidity during operation10 ... 95 %
supply voltage 1 at DC rated value30 V
● digital inputs parameterizableYes
yielded mechanical performance [hp]
● digital outputs parameterizableYes
Degree of protection (IP) (EF005474)IP65
product component motor brake outputNo
surge voltage resistance rated value6 000 V
Article Number (Market Facing Number)3RK1325-6LS71-1AA0
EMC immunity according to IEC 60947-1corresponds to degree of severity 3, ambience A (industrial sector)
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)12
Voltage type for actuating (EF008242)DC
With short-circuit release (EF006691)true
type of voltage of the supply voltageDC
● for auxiliary and control circuitconnector
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)true
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● between main and auxiliary circuit400 V
control supply voltage at DC rated value20.4 ... 28.8 V
number of poles for main current circuit3
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
touch protection against electrical shockfinger-safe
● between control and auxiliary circuit24 V
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)['1.5', '12']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
protocol is supported AS-Interface protocolYes
● due to burst according to IEC 61000-4-42 kV network connection / 1 kV control connection
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
type of voltage of the control supply voltageDC
● in switching state ON with bypass circuit8.2656 W
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
maximum permissible voltage for safe isolation
● in switching state OFF with bypass circuit1.9872 W
Rated operation power at AC-3, 400 V (EF001364)5.5
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
power loss [W] in auxiliary and control circuit
Rated control supply voltage Us at DC (EF003980)['20.4', '28.8']
● control circuit interface to parallel wiringNo
EMC emitted interference according to IEC 60947-1CISPR11, ambience A (group 2)
Rated operation current at AC-3, 400 V (EF009602)12
● at the manufacturer-specific device interfaceoptical interface
Supporting protocol for INTERBUS-Safety (EF006662)-
product extension braking module for brake controlNo
Supporting protocol for DeviceNet Safety (EF007520)-
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Supporting protocol for other bus systems (EF003062)-
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
breaking capacity maximum short-circuit current (Icu)
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
installation altitude at height above sea level maximum2 000 m
product function control circuit interface with IO linkNo
Coordination class according to IEC 60947-4-3 (EF012390)Class 1
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Other
● due to conductor-earth surge according to IEC 61000-4-52 kV
type of electrical connection of the communication interfaceM12 plug
Supporting protocol for AS-Interface Safety at Work (EF007519)-
● due to conductor-conductor surge according to IEC 61000-4-51 kV
Number of auxiliary contacts as normally open contact (EF001376)-
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
full-load current (FLA) for 3-phase AC motor at 480 V rated value11 A
Number of auxiliary contacts as normally closed contact (EF001377)-
operating voltage at AC at 60 Hz according to CSA and UL rated value480 V
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.2-methyl-1-(4-methyl... CAS-No. 71868-10-5 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-oneBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Type of electrical connection for auxiliary- and control current circuit (EF006979)Other
adjustable current response value current of the current-dependent overload release1.5 ... 12 A
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmationGeneral Product Approval

Product Description

SIRIUS ARRANCANC. ENGINE M200D AS-I COMMUNICATION: AS-ENTERFACE START. STANDARD ELECTRONIC LOCK INVERTER 3 AC 400V/5,5KW; 1,5A... 12.00A; PROTEC. ELECT. AGAINST OVERLOAD; THERMISTOR: THERMOCLICK / PTC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top