Key Specifications
:
EAN:4011209646957
UPC:662643245608
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209646957
UPC662643245608
ETIM5
depth150 mm
width110 mm
UNSPSC14
eClass6
height230 mm
● at DC24 ... 24 V
Group CodeR711
trip classCLASS 10
Date5/2/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
Product Group3723
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85371098
Product familyOrdering Data Overview
last modified:1/18/2021
Net Weight (kg)1,700 Kg
product feature
type of voltageAC
Depth (EF000049)150.0
Width (EF000008)110.0
fastening methodscrew fixing
product function
shock resistance15g / 11 ms
● direct startYes
Country of originGermany
Height (EF000040)230.0
mounting positionvertical, horizontal
number of sockets
● of the inputs2 byte
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
failure rate [FIT]
product brand nameSIMATIC
type of assignment1
● during storage-40 ... +70 °C
● of the outputs2 byte
Packaging Dimension228,00 x 309,00 x 184,00
Product DescriptionET 200pro DSE ST DOL starter Standard Mechanical switching Electronic overload protection AC-3, 0.9 kW / 400 V 0.15 A...2.00 A without brake contact Han Q4/2 - Han Q8/0
ambient temperature
degree of pollution3
operational current
product designationMotor starters
protection class IPIP65
With fuse (EF006693)-
vibration resistance2g
● during operation-25 ... +55 °C
● during transport-40 ... +70 °C
● reverse startingNo
design of the productdirect starter
protocol is supported
● PROFINET protocolYes
● at DC rated value20.4 ... 28.8 V
supply voltage 1 at DC24 ... 24 V
Product Lifecycle (PLM)PM300:Active Product
— with bypass circuit1.6416 W
● maximum permissible28.8 V
● minimum permissible20.4 V
General Product ApprovalEMC
Release class (EF006668)CLASS 10
control supply voltage 1
number of digital inputs0
product type designationET 200pro
● PROFIBUS DP protocolYes
● at 400 V rated value100 000 A
Declaration of ConformityTest Certificates
● in switching state ON
Export Control RegulationsAL : N / ECCN : N
— without bypass circuit1.6416 W
● for main energy infeedsocket according to ISO23570
● in switching state OFF
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
Package size unit of measureMM
UK Declaration of Conformity
type of the motor protectionsolid-state
Substance Prohibitance (Date)05/01/2012
operating voltage rated value200 ... 400 V
type of electrical connection
● for digital input signals0
insulation voltage rated value400 V
● at AC at 400 V rated value2 A
● brake control with 24 V DCNo
● for digital output signals0
design of the switching contactelectromechanical
● 1 for digital input signalsM12 socket
● 2 for digital input signalsM12 socket
● 3 for digital input signalsM12 socket
● 4 for digital input signalsM12 socket
● brake control with 180 V DCNo
● brake control with 230 V ACNo
● brake control with 400 V ACNo
● brake control with 500 V DCNo
Type of motor starter (EF009598)Direct online starter (DOL)
proportion of dangerous failures
● at AC-3 at 400 V rated value2 A
● for main energy transmissionsocket according to ISO23570
● for supply voltage line-sidevia backplane bus
Rail mounting possible (EF003972)-
● for load-side outgoing feedersocket according to ISO23570
● supports PROFIenergy shutdownYes
External reset possible (EF003426)-
design of short-circuit protectionfuse
product function bus communicationYes
product function on-site operationYes
relative humidity during operation5 ... 95 %
supply voltage 1 at DC rated value
● digital inputs parameterizableNo
● digital outputs parameterizableNo
● for supply voltage transmissionvia backplane bus
Degree of protection (IP) (EF005474)IP65
product component motor brake outputNo
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RK1304-5KS40-4AA0
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)2
Voltage type for actuating (EF008242)DC
With short-circuit release (EF006691)true
address space memory of address range
type of voltage of the supply voltageDC
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)false
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
reference code according to IEC 81346-2Q
control supply voltage at DC rated value20.4 ... 28.8 V
number of poles for main current circuit3
● supports PROFIenergy measured valuesYes
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
design of the interface PROFINET protocolYes
product function short circuit protectionYes
touch protection against electrical shockfinger-safe
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)['0.15', '2']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
protocol is supported AS-Interface protocolNo
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
operating power at AC-3 at 400 V rated value900 W
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
type of voltage of the control supply voltageDC
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
● with low demand rate according to SN 3192050 %
Rated operation power at AC-3, 400 V (EF001364)0.9
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
power loss [W] in auxiliary and control circuit
● with high demand rate according to SN 3192075 %
Rated control supply voltage Us at DC (EF003980)['20.4', '28.8']
Rated operation current at AC-3, 400 V (EF009602)2
● at the manufacturer-specific device interfaceoptical interface
Supporting protocol for INTERBUS-Safety (EF006662)-
Supporting protocol for DeviceNet Safety (EF007520)-
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Supporting protocol for other bus systems (EF003062)-
operating power for 3-phase motors at 400 V at 50 Hz70 ... 900 W
Ambient temperature, upper operating limit (EF009603)-
B10 value with high demand rate according to SN 319201 000 000
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
breaking capacity maximum short-circuit current (Icu)
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
type of electrical connection for main current circuittab terminals
installation altitude at height above sea level maximum3 500 m
Coordination class according to IEC 60947-4-3 (EF012390)Class 1
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Flat plug-in connection
type of electrical connection of the communication interfacevia backplane bus
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)-
operating range relative to the operating voltage at AC at 50 Hz200 ... 440 V
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
Number of auxiliary contacts as normally closed contact (EF001377)-
operating voltage at AC at 60 Hz according to CSA and UL rated value600 V
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
T1 value for proof test interval or service life according to IEC 6150820 y
mechanical service life (switching cycles) of the main contacts typical30 000 000
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
maximum permissible voltage for safe isolation between main and auxiliary circuit400 V
Type of electrical connection for auxiliary- and control current circuit (EF006979)-
adjustable current response value current of the current-dependent overload release0.15 ... 2 A
General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherDangerous GoodUK Declaration of ConformityType Test Certificates/Test ReportConfirmationTransport InformationGeneral Product Approval

Product Description

ET 200PRO DSE ST ARRANC. DIRECT STANDARD; MECHANICAL MANEUVER; PROTEC. SOBREINT. ELECTRONICA 3 AC 400V/0.9KW; 0.15A... 2,00A SINSIRIUS BRAKE Contactor HAN Q4/2 - HAN Q8/0
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top