| Parameter | Value |
|---|---|
| EAN | 4011209646742 |
| UPC | 662643244274 |
| ETIM | 5 |
| depth | 170 mm |
| width | 110 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 230 mm |
| ● at DC | 24 ... 24 V |
| Group Code | R711 |
| Metal Factor | LAO----- |
| Date5/14/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 3723 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85371098 |
| Product family | ET 200pro isolator module |
| last modified: | 1/18/2021 |
| Net Weight (kg) | 1,710 Kg |
| product feature | |
| type of voltage | AC |
| Depth (EF000049) | 170.0 |
| Width (EF000008) | 110.0 |
| fastening method | screw fixing |
| product function | |
| shock resistance | 15g / 11 ms |
| Country of origin | Germany |
| Height (EF000040) | 230.0 |
| mounting position | any |
| number of sockets | |
| ● of the inputs | 1 byte |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| product brand name | SIMATIC |
| type of assignment | 1 |
| ● during storage | -40 ... +70 °C |
| ● of the outputs | 0 byte |
| Packaging Dimension | 228,00 x 309,00 x 184,00 |
| Product Description | ET 200 RSM Maintenance switch module Up to 25 A Up to 25 A Disconnector function for Main circuit Han Q4/2 |
| ambient temperature | |
| degree of pollution | 3 |
| operational current | |
| product designation | Motor starters |
| protection class IP | IP65 |
| With fuse (EF006693) | - |
| vibration resistance | 2g |
| ● during operation | -25 ... +55 °C |
| ● during transport | -40 ... +70 °C |
| design of the product | maintenance switch |
| protocol is supported | |
| ● PROFINET protocol | Yes |
| ● at DC rated value | 20.4 ... 28.8 V |
| supply voltage 1 at DC | 24 ... 24 V |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● maximum permissible | 28.8 V |
| ● minimum permissible | 20.4 V |
| General Product Approval | EMC |
| Release class (EF006668) | - |
| control supply voltage 1 | |
| number of digital inputs | 0 |
| product type designation | ET 200pro |
| ● PROFIBUS DP protocol | Yes |
| ● at 400 V rated value | 50 000 A |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : N |
| ● for main energy infeed | socket according to ISO23570 |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| Package size unit of measure | MM |
| UK Declaration of Conformity | |
| Substance Prohibitance (Date) | 05/01/2012 |
| operating voltage rated value | 200 ... 400 V |
| type of electrical connection | |
| ● for digital input signals | 0 |
| insulation voltage rated value | 400 V |
| ● at AC at 400 V rated value | 25 A |
| ● brake control with 24 V DC | No |
| ● for digital output signals | 0 |
| ● 1 for digital input signals | M12 socket |
| ● 2 for digital input signals | M12 socket |
| ● 3 for digital input signals | M12 socket |
| ● 4 for digital input signals | M12 socket |
| ● brake control with 180 V DC | No |
| ● brake control with 230 V AC | No |
| ● brake control with 400 V AC | No |
| ● brake control with 500 V DC | No |
| Type of motor starter (EF009598) | Repair switch |
| ● at AC-3 at 400 V rated value | 25 A |
| ● for main energy transmission | socket according to ISO23570 |
| ● for supply voltage line-side | via backplane bus |
| Rail mounting possible (EF003972) | - |
| ● for load-side outgoing feeder | socket according to ISO23570 |
| ● supports PROFIenergy shutdown | No |
| External reset possible (EF003426) | - |
| design of short-circuit protection | circuit-breakers |
| product function bus communication | Yes |
| product function on-site operation | Yes |
| relative humidity during operation | 5 ... 95 % |
| supply voltage 1 at DC rated value | |
| ● digital inputs parameterizable | No |
| ● digital outputs parameterizable | No |
| ● for supply voltage transmission | via backplane bus |
| Degree of protection (IP) (EF005474) | IP65 |
| category according to EN ISO 13849-1 | 4 |
| product component motor brake output | No |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3RK1304-0HS00-6AA0 |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | 25 |
| Voltage type for actuating (EF008242) | DC |
| With short-circuit release (EF006691) | true |
| address space memory of address range | |
| type of voltage of the supply voltage | DC |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| reference code according to IEC 81346-2 | Q |
| control supply voltage at DC rated value | 20.4 ... 28.8 V |
| number of poles for main current circuit | 3 |
| ● supports PROFIenergy measured values | No |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| design of the interface PROFINET protocol | Yes |
| product function short circuit protection | Yes |
| touch protection against electrical shock | finger-safe |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | ['25', '25'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| protocol is supported AS-Interface protocol | No |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| type of voltage of the control supply voltage | DC |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| Rated operation power at AC-3, 400 V (EF001364) | - |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| PFHD with high demand rate according to EN 62061 | 0.000000000054 1/h |
| Rated control supply voltage Us at DC (EF003980) | ['20.4', '28.8'] |
| Rated operation current at AC-3, 400 V (EF009602) | 25 |
| ● at the manufacturer-specific device interface | optical interface |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| performance level (PL) according to EN ISO 13849-1 | e |
| Safety Integrity Level (SIL) according to IEC 61508 | 3 |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| Supporting protocol for other bus systems (EF003062) | - |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| breaking capacity maximum short-circuit current (Icu) | |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| type of electrical connection for main current circuit | tab terminals |
| installation altitude at height above sea level maximum | 3 500 m |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Flat plug-in connection |
| type of electrical connection of the communication interface | via backplane bus |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| Number of auxiliary contacts as normally open contact (EF001376) | - |
| operating range relative to the operating voltage at AC at 50 Hz | 200 ... 440 V |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| Number of auxiliary contacts as normally closed contact (EF001377) | - |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 600 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| T1 value for proof test interval or service life according to IEC 61508 | 10 y |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| maximum permissible voltage for safe isolation between main and auxiliary circuit | 400 V |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - |
| adjustable current response value current of the current-dependent overload release | 25 ... 25 A |
| General Product ApprovalEMCConfirmationDeclaration of ConformityTest CertificatesotherUK Declaration of ConformityType Test Certificates/Test ReportConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide