


| Parameter | Value |
|---|---|
| Confirmation | |
| EAN | 4011209548640 |
| UPC | Not available |
| ETIM | 5 |
| MTBF | 11 y |
| MTTFd | 31 y |
| Notes | Sucessor:The successor is the ET 200SP system with its compact motor starter modules. |
| depth | 150 mm |
| width | 130 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 290 mm |
| ● at DC | 24 ... 24 V |
| Group Code | R711 |
| safe state | Load circuit open |
| trip class | CLASS 10 and 20 adjustable |
| Metal Factor | LAO----- |
| Date5/12/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Product Group | 4962 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | Ordering Data Overview |
| last modified: | 12/15/2020 |
| Net Weight (kg) | 2,513 Kg |
| product feature | |
| Depth (EF000049) | 150.0 |
| Width (EF000008) | 130.0 |
| fastening method | pluggable on terminal module |
| product function | |
| shock resistance | 5g / 11 ms |
| ● direct start | No |
| Country of origin | Germany |
| Height (EF000040) | 290.0 |
| mounting position | vertical, horizontal |
| number of sockets | |
| ● of the inputs | 2 byte |
| LKZ_FDB/ CatalogID | CC-IC10 |
| PLM Effective Date | Product phase-out since: 01.10.2020 |
| Packaging Quantity | 1 |
| failure rate [FIT] | |
| product brand name | SIMATIC |
| type of assignment | 2 |
| ● during storage | -40 ... +70 °C |
| ● of the outputs | 2 byte |
| Packaging Dimension | 229,00 x 333,00 x 197,00 |
| Product Description | F-RS1E-X for ET 200S Failsafe reversing starter Setting range 2.4...16 A Mechanical switching Electronic protection AC-3, up to 7.5 kW / 400 V expandable for brake control module for 2DI control module |
| ambient temperature | |
| degree of pollution | 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131) |
| operational current | |
| product designation | Motor starters |
| With fuse (EF006693) | - |
| vibration resistance | 2g |
| ● during operation | 0 ... 60 °C |
| ● during transport | -40 ... +70 °C |
| ● reverse starting | Yes |
| design of the product | reversing starter |
| protocol is supported | |
| ● PROFINET protocol | Yes |
| ● at DC rated value | 21.6 ... 26.4 V |
| conducted interference | |
| supply voltage 1 at DC | 24 ... 24 V |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| ● maximum permissible | 28.8 V |
| ● minimum permissible | 20.4 V |
| General Product Approval | EMC |
| Release class (EF006668) | Other |
| control supply voltage 1 | |
| number of digital inputs | 2 |
| product type designation | ET 200S |
| ● PROFIBUS DP protocol | Yes |
| ● at 400 V rated value | 50 kA |
| Export Control Regulations | AL : N / ECCN : N |
| ● for main energy infeed | screw-type terminals |
| Safe failure fraction (SFF) | 99.5 % |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| operating frequency maximum | 80 1/h |
| Package size unit of measure | MM |
| Type Examination Certificate | |
| type of the motor protection | solid-state |
| Substance Prohibitance (Date) | 10/26/2016 |
| operating voltage rated value | 200 ... 400 V |
| type of electrical connection | |
| ● for digital input signals | 0 |
| insulation voltage rated value | 500 V |
| ● brake control with 24 V DC | No |
| ● for digital output signals | 0 |
| design of the switching contact | electromechanical |
| ● 1 for digital input signals | using control module |
| ● 2 for digital input signals | using control module |
| ● brake control with 180 V DC | No |
| ● brake control with 230 V AC | No |
| ● brake control with 500 V DC | No |
| Type of motor starter (EF009598) | Reversing starter |
| ● at AC-3 at 400 V rated value | 16 A |
| ● for main energy transmission | via energy bus |
| ● for supply voltage line-side | via backplane bus |
| Rail mounting possible (EF003972) | - |
| operating frequency 1 rated value | 50 Hz |
| operating frequency 2 rated value | 60 Hz |
| ● for load-side outgoing feeder | Screw-type terminals |
| External reset possible (EF003426) | - |
| design of short-circuit protection | circuit-breakers |
| product function bus communication | Yes |
| product function on-site operation | Yes |
| relative humidity during operation | 5 ... 95 % |
| supply voltage 1 at DC rated value | |
| ● digital inputs parameterizable | Yes |
| ● for communication transmission | via backplane bus |
| ● of the communication interface | via backplane bus |
| ● digital outputs parameterizable | No |
| ● for supply voltage transmission | via backplane bus |
| Degree of protection (IP) (EF005474) | IP20 |
| category according to EN ISO 13849-1 | 4 |
| product component motor brake output | Yes |
| surge voltage resistance rated value | 6 kV |
| Article Number (Market Facing Number) | 3RK1301-0CB13-1AA2 |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
| Functional Safety/Safety of Machinery | Declaration of Conformity |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | - |
| Voltage type for actuating (EF008242) | DC |
| With short-circuit release (EF006691) | true |
| address space memory of address range | |
| stop category according to EN 60204-1 | 0 |
| type of voltage of the supply voltage | DC |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | false |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| reference code according to IEC 81346-2 | Q |
| control supply voltage at DC rated value | 21.6 ... 26.4 V |
| number of poles for main current circuit | 3 |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| average diagnostic coverage level (DCavg) | 99 % |
| design of the interface PROFINET protocol | Yes |
| product function short circuit protection | Yes |
| Supporting protocol for SUCONET (EF003060) | - |
| Overload release current setting (EF002336) | ['2.4', '16'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| protocol is supported AS-Interface protocol | No |
| safety device type according to IEC 61508-2 | Type B |
| ● due to burst according to IEC 61000-4-4 | 2 kV on voltage supply, inputs and outputs |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| operating power at AC-3 at 400 V rated value | 7.5 kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| type of voltage of the control supply voltage | DC |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| Rated operation power at AC-3, 400 V (EF001364) | 7.5 |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| hardware fault tolerance according to IEC 61508 | 1 |
| PFHD with high demand rate according to EN 62061 | 0.0000000018 1/h |
| Rated control supply voltage Us at DC (EF003980) | ['21.6', '26.4'] |
| EMC emitted interference according to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
| Rated operation current at AC-3, 400 V (EF009602) | - |
| SIL Claim Limit (subsystem) according to EN 62061 | SILCL 3 |
| ● at the manufacturer-specific device interface | plug |
| PFDavg with low demand rate according to IEC 61508 | 0.00008 |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| performance level (PL) according to EN ISO 13849-1 | e |
| product extension braking module for brake control | Yes |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| field-based interference according to IEC 61000-4-3 | 80 MHz ... 1 GHz 10 V/m, 1.4 GHz ...2 Hz 3 V/m, 2 GHz ... 2.7 GHz 1 V/m |
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D |
| Supporting protocol for other bus systems (EF003062) | - |
| operating power for 3-phase motors at 400 V at 50 Hz | 1.1 ... 7.5 kW |
| touch protection on the front according to IEC 60529 | finger-safe |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - |
| breaking capacity maximum short-circuit current (Icu) | |
| ● at rate of recognizable hazardous failures (λdd) | 3 800 FIT |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| relative negative tolerance of the operating frequency | 10 % |
| relative positive tolerance of the operating frequency | 10 % |
| type of electrical connection for main current circuit | screw-type terminals |
| installation altitude at height above sea level maximum | 2 000 m |
| protection class IP on the front according to IEC 60529 | IP20 |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 2 |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| ● at rate of non-recognizable hazardous failures (λdu) | 25 FIT |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV (U > 24 V DC) |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV (U > 24 V DC) |
| Number of auxiliary contacts as normally open contact (EF001376) | - |
| operating range relative to the operating voltage at AC at 50 Hz | 200 ... 440 V |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| Number of auxiliary contacts as normally closed contact (EF001377) | - |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 600 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 26.10.2016 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| T1 value for proof test interval or service life according to IEC 61508 | 20 y |
| mechanical service life (switching cycles) of the main contacts typical | 100 000 |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| power loss [W] for rated value of the current without load current share typical | 4.44 W |
| maximum permissible voltage for safe isolation between main and auxiliary circuit | 400 V |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | - |
| adjustable current response value current of the current-dependent overload release | 2.4 ... 16 A |
| Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 61508 | 0.00008 1/y |
| General Product ApprovalEMCConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesotherDangerous GoodType Examination CertificateUK Declaration of ConformityType Test Certificates/Test ReportConfirmationTransport Information | General Product Approval |
Technical specifications and performance data
Installation and operation guide