3RK1301-0AB13-1AA2 - 3RK1301-0AB13-1AA2 SIEMENS F-RS1E-X for ET 200S Failsafe reversing starter Setting range 0.3...3 A Mechanica..
In Stock Hot Product

3RK1301-0AB13-1AA2

3RK1301-0AB13-1AA2 SIEMENS F-RS1E-X for ET 200S Failsafe reversing starter Setting range 0.3...3 A Mechanica..

$0.00USD
3906 in stock
Key Specifications
:
EAN:4011209548626
UPC:662643245615
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209548626
UPC662643245615
ETIM5
MTBF11 y
MTTFd31 y
NotesSucessor:The successor is the ET 200SP system with its compact motor starter modules.
depth150 mm
width130 mm
UNSPSC14
eClass6
height290 mm
● at DC24 ... 24 V
Group CodeR711
safe stateLoad circuit open
trip classCLASS 10 and 20 adjustable
Date5/8/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorLAO-----
Product Group4962
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85364900
Product familyOrdering Data Overview
last modified:12/15/2020
Net Weight (kg)2,543 Kg
product feature
Depth (EF000049)150.0
Width (EF000008)130.0
fastening methodpluggable on terminal module
product function
shock resistance5g / 11 ms
● direct startNo
Country of originGermany
Height (EF000040)290.0
mounting positionvertical, horizontal
number of sockets
● of the inputs2 byte
LKZ_FDB/ CatalogIDCC-IC10
PLM Effective DateProduct phase-out since: 01.10.2020
Packaging Quantity1
failure rate [FIT]
product brand nameSIMATIC
type of assignment2
● during storage-40 ... +70 °C
● of the outputs2 byte
Packaging Dimension229,00 x 333,00 x 197,00
Product DescriptionF-RS1E-X for ET 200S Failsafe reversing starter Setting range 0.3...3 A Mechanical switching Electronic protection AC-3, up to 1.1 kW / 400 V expandable for brake control module for 2DI control module
ambient temperature
degree of pollution3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
operational current
product designationMotor starters
With fuse (EF006693)-
vibration resistance2g
● during operation0 ... 60 °C
● during transport-40 ... +70 °C
● reverse startingYes
design of the productreversing starter
protocol is supported
● PROFINET protocolYes
● at DC rated value21.6 ... 26.4 V
conducted interference
supply voltage 1 at DC24 ... 24 V
Product Lifecycle (PLM)PM400:Phase Out Started
● maximum permissible28.8 V
● minimum permissible20.4 V
General Product ApprovalEMC
Release class (EF006668)Other
control supply voltage 1
number of digital inputs2
product type designationET 200S
● PROFIBUS DP protocolYes
● at 400 V rated value50 kA
Export Control RegulationsAL : N / ECCN : N
● for main energy infeedscrew-type terminals
Safe failure fraction (SFF)99.5 %
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
operating frequency maximum80 1/h
Package size unit of measureMM
Type Examination Certificate
type of the motor protectionsolid-state
Substance Prohibitance (Date)10/26/2016
operating voltage rated value200 ... 400 V
type of electrical connection
● for digital input signals0
insulation voltage rated value500 V
● brake control with 24 V DCNo
● for digital output signals0
design of the switching contactelectromechanical
● 1 for digital input signalsusing control module
● 2 for digital input signalsusing control module
● brake control with 180 V DCNo
● brake control with 230 V ACNo
● brake control with 500 V DCNo
Type of motor starter (EF009598)Reversing starter
● at AC-3 at 400 V rated value3 A
● for main energy transmissionvia energy bus
● for supply voltage line-sidevia backplane bus
Rail mounting possible (EF003972)-
operating frequency 1 rated value50 Hz
operating frequency 2 rated value60 Hz
● for load-side outgoing feederScrew-type terminals
● supports PROFIenergy shutdownNo
External reset possible (EF003426)-
design of short-circuit protectioncircuit-breakers
product function bus communicationYes
product function on-site operationYes
relative humidity during operation5 ... 95 %
supply voltage 1 at DC rated value
● digital inputs parameterizableYes
● for communication transmissionvia backplane bus
● of the communication interfacevia backplane bus
● digital outputs parameterizableNo
● for supply voltage transmissionvia backplane bus
Degree of protection (IP) (EF005474)IP20
category according to EN ISO 13849-14
product component motor brake outputYes
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RK1301-0AB13-1AA2
EMC immunity according to IEC 60947-1corresponds to degree of severity 3, ambience A (industrial sector)
Functional Safety/Safety of MachineryDeclaration of Conformity
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)-
Voltage type for actuating (EF008242)DC
With short-circuit release (EF006691)true
address space memory of address range
stop category according to EN 60204-10
type of voltage of the supply voltageDC
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)false
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
reference code according to IEC 81346-2Q
control supply voltage at DC rated value21.6 ... 26.4 V
number of poles for main current circuit3
● supports PROFIenergy measured valuesNo
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
average diagnostic coverage level (DCavg)99 %
design of the interface PROFINET protocolYes
product function short circuit protectionYes
Supporting protocol for SUCONET (EF003060)-
Overload release current setting (EF002336)['0.3', '3']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
protocol is supported AS-Interface protocolNo
safety device type according to IEC 61508-2Type B
● due to burst according to IEC 61000-4-42 kV on voltage supply, inputs and outputs
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
operating power at AC-3 at 400 V rated value1.1 kW
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
type of voltage of the control supply voltageDC
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Rated operation power at AC-3, 400 V (EF001364)1.1
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
hardware fault tolerance according to IEC 615081
PFHD with high demand rate according to EN 620610.0000000018 1/h
Rated control supply voltage Us at DC (EF003980)['21.6', '26.4']
EMC emitted interference according to IEC 60947-1CISPR11, ambience A (industrial sector)
Rated operation current at AC-3, 400 V (EF009602)-
SIL Claim Limit (subsystem) according to EN 62061SILCL 3
● at the manufacturer-specific device interfaceplug
PFDavg with low demand rate according to IEC 615080.00008
Supporting protocol for INTERBUS-Safety (EF006662)-
performance level (PL) according to EN ISO 13849-1e
product extension braking module for brake controlYes
Supporting protocol for DeviceNet Safety (EF007520)-
field-based interference according to IEC 61000-4-380 MHz ... 1 GHz 10 V/m, 1.4 GHz ...2 Hz 3 V/m, 2 GHz ... 2.7 GHz 1 V/m
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Supporting protocol for other bus systems (EF003062)-
operating power for 3-phase motors at 400 V at 50 Hz0.1 ... 1.1 kW
touch protection on the front according to IEC 60529finger-safe
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)-
Rated control supply voltage Us at AC 60HZ (EF003979)-
breaking capacity maximum short-circuit current (Icu)
● at rate of recognizable hazardous failures (λdd)3 800 FIT
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
relative negative tolerance of the operating frequency10 %
relative positive tolerance of the operating frequency10 %
type of electrical connection for main current circuitscrew-type terminals
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Coordination class according to IEC 60947-4-3 (EF012390)Class 2
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Screw connection
● at rate of non-recognizable hazardous failures (λdu)25 FIT
● due to conductor-earth surge according to IEC 61000-4-52 kV (U > 24 V DC)
Supporting protocol for AS-Interface Safety at Work (EF007519)-
● due to conductor-conductor surge according to IEC 61000-4-51 kV (U > 24 V DC)
Number of auxiliary contacts as normally open contact (EF001376)-
operating range relative to the operating voltage at AC at 50 Hz200 ... 440 V
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
Number of auxiliary contacts as normally closed contact (EF001377)-
operating voltage at AC at 60 Hz according to CSA and UL rated value600 V
Compliance with the substance restrictions according to RoHS directiveSince: 26.10.2016
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
T1 value for proof test interval or service life according to IEC 6150820 y
mechanical service life (switching cycles) of the main contacts typical100 000
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead titanium zircon... CAS-No. 12626-81-2 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead titanium zirconium oxideBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
power loss [W] for rated value of the current without load current share typical4.44 W
maximum permissible voltage for safe isolation between main and auxiliary circuit400 V
Type of electrical connection for auxiliary- and control current circuit (EF006979)-
adjustable current response value current of the current-dependent overload release0.3 ... 3 A
Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 615080.00008 1/y
General Product ApprovalEMCConfirmationFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesotherDangerous GoodType Examination CertificateUK Declaration of ConformityType Test Certificates/Test ReportConfirmationTransport InformationGeneral Product Approval

Product Description

F-RS1E-X FOR ET 200S STARTER-INVERTER FAILSAFE RANGE REGULATION 0,3...3A MECHANICAL MANEUVER ELECTRONIC PROTECTION AC-3, UP TO 1,1KW / 400V, EXPANDABLE FOR BRAKE CONTROL MODULE FOR CONTROL MODULE 2 DI
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide