Service time: Monday to Friday 9:00-18:00
3RF2440-1AB45 - 3RF2440-1AB45 SIEMENS Solid-state contactor 3-phase 3RF2 AC 51 / 40 A / 40 °C 48-600 V / 4-30 V DC 2-phase c..
In Stock Hot Product

3RF2440-1AB45

3RF2440-1AB45 SIEMENS Solid-state contactor 3-phase 3RF2 AC 51 / 40 A / 40 °C 48-600 V / 4-30 V DC 2-phase c..

$0.00USD
4657 in stock
Key Specifications
:
EAN:4011209647183
UPC:040892554069
ETIM:6
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209647183
UPC040892554069
ETIM6
IDEA4
depth128 mm
width89.5 mm
UNSPSC14
eClass6
height100 mm
— solid2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
● at DC4 ... 30 V
Group CodeR711
Date5/3/2022Subject to change without notice© Copyright Siemens 2022
Metal FactorNone
● at 50 Hz40 ... 660 V
● at 60 Hz40 ... 660 V
ON-delay time1 ms; additionally max. one half-wave
Product Group3725
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85364900
Product familySIRIUS 3RF2 solid-state relays and solid-state contactors
last modified:1/26/2022
Net Weight (kg)0,563 Kg
● up to 460 V3NA3812; These fuses have a smaller rated current than the semiconductor relays
fastening methodscrew fixing and snap-on mounting on standard mounting rail 35 mm according to IEC 60715
product functionzero-point switching
Country of originGermany
I2t value maximum6 600 A²·s
Test Certificatesother
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-55 ... +80 °C
Packaging Dimension110,00 x 125,00 x 172,00
Product DescriptionSolid-state contactor 3-phase 3RF2 AC 51 / 40 A / 40 °C 48-600 V / 4-30 V DC 2-phase controlled screw terminal Blocking voltage 1200 V
ambient temperature
degree of pollution3
operational current
product designationsolid-state contactor
derating temperature40 °C
● during operation-25 ... +60 °C
design of the producttwo-phase controlled
● at DC rated value30 V
● for main contacts
● solid or stranded1.5 ... 6 mm²
conducted interference
control supply voltage
Product Lifecycle (PLM)PM300:Active Product
operating voltage at AC
General Product ApprovalEMC
control supply voltage 1
product type designation3RF24
● at 50 Hz rated value48 ... 600 V
● at 60 Hz rated value48 ... 600 V
● at AC-51 rated value40 A
● side-by-side mountingYes
Export Control RegulationsAL : N / ECCN : N
Modular version (EF001126)true
Standard lead time ex-works40 Day/Days
Surcharge for Raw MaterialsNone
operational current minimum500 mA
tightening torque [lbf·in]
Package size unit of measureMM
stripped length of the cable
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)07/01/2006
manufacturer's article number
type of electrical connection
insulation voltage rated value600 V
operating frequency rated value50 ... 60 Hz
reverse current of the thyristor10 mA
control current at DC rated value30 mA
Type Test Certificates/Test ReportConfirmation
● according to UL 508 rated value30 A
● at AWG cables for main contacts2x (14 ... 10)
surge current resistance rated value1 150 A
symmetrical line frequency tolerance5 Hz
Article Number (Market Facing Number)3RF2440-1AB45
Rated operation power NEMA (EF011960)-
Voltage type for actuating (EF008242)DC
● for auxiliary and control circuitscrew-type terminals
WEEE (2012/19/EU) Take-Back ObligationYes
● for auxiliary and control contacts
number of NC contacts for main contacts0
number of NO contacts for main contacts2
reference code according to IEC 81346-2Q
● at AC-51 according to IEC 60947-4-330 A
number of poles for main current circuit3
● of the auxiliary and control contactsM3
● due to burst according to IEC 61000-4-42 kV / 5 kHz behavior criterion 2
design of the thread of the connection screw
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
shock resistance according to IEC 60068-2-2715g / 11 ms
type of connectable conductor cross-sections
— finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
● finely stranded with core end processing1 ... 10 mm²
type of voltage of the control supply voltageDC
● _2 of the accessories that can be ordered3RF2900-0EA18
Rated operation power at AC-3, 400 V (EF001364)-
Rated operation power at AC-4, 400 V (EF008496)-
vibration resistance according to IEC 60068-2-62g
— finely stranded without core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
● for main contacts with screw-type terminals2 ... 2.5 N·m
Rated control supply voltage Us at DC (EF003980)['4', '30']
● at DC initial value for signal <1> detection4 V
control current at minimum control supply voltage
electrostatic discharge according to IEC 61000-4-24 kV contact discharging / 8 kV air discharging, behavior criterion 2
Rated operation current Ie at AC-1, 400 V (EF001393)40
Rated operation current Ie at AC-3, 400 V (EF001392)-
Rated operation current Ie at AC-4, 400 V (EF008495)-
Region Specific PriceGroup / Headquarter Price Group41C / 41C
surge voltage resistance of main circuit rated value6 kV
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● at AWG cables for auxiliary and control contacts1x (AWG 20 ... 12)
● at DC full-scale value for signal<0> recognition1 V
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
connectable conductor cross-section for main contacts
installation altitude at height above sea level maximum1 000 m
operating range relative to the operating voltage at AC
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
conducted HF interference emissions according to CISPR11Class A for industrial environment
field-bound HF interference emission according to CISPR11Class A for industrial environment
relative symmetrical tolerance of the operating frequency10 %
Number of main contacts as normally open contact (EF001374)2
● due to conductor-earth surge according to IEC 61000-4-52 kV behavior criterion 2
Number of normally closed contacts as main contact (EF001375)0
● due to high-frequency radiation according to IEC 61000-4-6140 dBuV in the frequency range 0.15 ... 80 MHz, behavior criterion 1
● due to conductor-conductor surge according to IEC 61000-4-51 kV behavior criterion 2
Number of auxiliary contacts as normally open contact (EF001376)0
manufacturer's article number of the gG fuse at NH design usable
● for auxiliary and control contacts with screw-type terminals0.5 ... 0.6 N·m
Number of auxiliary contacts as normally closed contact (EF001377)0
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
blocking voltage at the thyristor for main contacts maximum permissible1 200 V
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
AWG number as coded connectable conductor cross section for main contacts14 ... 10
rate of voltage rise at the thyristor for main contacts maximum permissible1 000 V/µs
● of back-up R fuse link for semiconductor protection at NH design usable3NE8017-1
● of full range R fuse link for semiconductor protection at NH design usable3NE1802-0
power loss [W] for rated value of the current without load current share typical0.9 W
● of full range R fuse link for semiconductor protection at cylindrical design usable5SE1350; Maximum operating voltage 400 V!
● of back-up R fuse link for semiconductor protection at cylindrical design 14 x 51 mm usable3NC1450
● of back-up R fuse link for semiconductor protection at cylindrical design 22 x 58 mm usable3NC2280
General Product ApprovalEMCDeclaration of ConformityConfirmationTest CertificatesotherType Test Certificates/Test ReportConfirmationGeneral Product Approval

Product Description

SIRIUS Three-phase solid state contactor 3RF2 AC51 40A 40 Degrees C 48-600V / 4-30V DC 2 Phases Controlled Screw Connection reverse voltage 1200V. Manufactured to order. Non-Cancelable Non-Returnable.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top