Service time: Monday to Friday 9:00-18:00
3RB3036-2UD0 - 3RB3036-2UD0 SIEMENS Overload relay 12.5...50 A Electronic For motor protection Size S2, Class 20E Contactor..
In Stock Hot Product

3RB3036-2UD0

3RB3036-2UD0 SIEMENS Overload relay 12.5...50 A Electronic For motor protection Size S2, Class 20E Contactor..

$0.00USD
3763 in stock
Key Specifications
:
EAN:4011209936379
UPC:887621914639
ETIM:5
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EAN4011209936379
UPC887621914639
ETIM5
IDEA4
depth104 mm
width55 mm
UNSPSC15
eClass6
height99 mm
● notefor contactor disconnection
— solid1x (1 ... 50 mm²), 2x (1 ... 35 mm²)
Group CodeR711
trip classCLASS 20E
● at 24 V4 A
● at 60 V0.55 A
Metal FactorL-O-----
— stranded2x (10 ... 35 mm²), 1x 50 mm²
● at 110 V4 A
● at 120 V4 A
● at 125 V4 A
● at 220 V0.11 A
● at 230 V3 A
● per pole0.6 W
Date5/14/2022Subject to change without notice© Copyright Siemens 2022
Product Group5350
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Commodity Code85364900
Product family3RB30, 3RB31 for standard applications
last modified:2/9/2022
Net Weight (kg)0,185 Kg
operating power
thermal current50 A
● rated value690 V
fastening methodContactor mounting
shock resistance15g / 11 ms
Country of originCzech Republic
Marine / Shippingother
mounting positionany
operating voltage
tightening torque
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
product brand nameSIRIUS
● during storage-40 ... +80 °C
Packaging Dimension121,00 x 122,00 x 68,00
Product DescriptionOverload relay 12.5...50 A Electronic For motor protection Size S2, Class 20E Contactor mounting Main circuit: Screw Auxiliary circuit: Spring-type terminal Manual-Automatic-Reset
ambient temperature
product designationsolid-state overload relay
vibration resistance1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles
● during operation-25 ... +60 °C
● during transport-40 ... +80 °C
— solid or stranded2x (0,25 ... 1,5 mm²)
● for main contacts
conducted interference
size of overload relayS2
Product Lifecycle (PLM)PM300:Active Product
design of the fuse link
General Product ApprovalEMC
Release class (EF006668)CLASS 20
product type designation3RB3
temperature compensation-25 ... +60 °C
● at 480 V rated value50 A
● at 600 V rated value50 A
Export Control RegulationsAL : N / ECCN : EAR99
Mounting method (EF000003)-
● for auxiliary contacts
Standard lead time ex-works80 Day/Days
Surcharge for Raw MaterialsNone
design of screwdriver shaftDiameter 5 to 6 mm
size of the screwdriver tipPozidriv PZ 2
Package size unit of measureMM
● for main current circuitscrew-type terminals
Substance Prohibitance (Date)10/15/2014
type of electrical connection
For use in hazardous locationsDeclaration of Conformity
design of the auxiliary switchintegrated
design of the overload releaseelectronic
Reset function input (EF011940)-
operating frequency rated value50 ... 60 Hz
operational current rated value50 A
● according to IEC 60068-2-2715g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 8g / 11 ms
● at AC-3e rated value maximum690 V
relative humidity during operation10 ... 95 %
Adjustable current range (EF008211)['12.5', '50']
Reset function automatic (EF011941)-
● at AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
● for AC motors at 500 V at 50 Hz11 ... 30 kW
● for AC motors at 690 V at 50 Hz11 ... 45 kW
display version for switching statusSlide switch
surge voltage resistance rated value6 kV
Article Number (Market Facing Number)3RB3036-2UD0
Reset function push-button (EF011942)-
Voltage type for actuating (EF008242)-
● for auxiliary and control circuitspring-loaded terminals
WEEE (2012/19/EU) Take-Back ObligationYes
— with type of assignment 2 requiredgG: 200 A
● between main and auxiliary circuit600 V
reference code according to IEC 81346-2F
number of poles for main current circuit3
— with type of coordination 1 requiredgG: 250 A
● at AWG cables for auxiliary contacts1x (24 ... 16), 2x (24 ... 16)
● for 3-phase motors at 400 V at 50 Hz7.5 ... 22 kW
● between auxiliary and auxiliary circuit300 V
● due to burst according to IEC 61000-4-42 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
design of the thread of the connection screw
full-load current (FLA) for 3-phase AC motor
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
type of connectable conductor cross-sections
— finely stranded with core end processing1x (1 ... 35 mm²), 2x (1 ... 25 mm²)
— finely stranded without core end processing2x (0.25 ... 1.5 mm²)
● for main contacts with screw-type terminals3 ... 4.5 N·m
Rated control supply voltage Us at DC (EF003980)['-', '-']
operational current at AC-3e at 400 V rated value50 A
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
operational current of auxiliary contacts at AC-15
operational current of auxiliary contacts at DC-13
size of contactor can be combined company-specificS2
field-based interference according to IEC 61000-4-310 V/m
type of voltage supply via input/output link masterNo
Region Specific PriceGroup / Headquarter Price Group41G / 41G
contact rating of auxiliary contacts according to ULB600 / R300
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
● for short-circuit protection of the main circuit
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
Type of electrical connection of main circuit (EF006819)Screw connection
type of protection according to ATEX directive 2014/34/EUEx II (2) G [Ex e] [Ex d] [Ex px] ; Ex II (2) D [Ex t] [Ex p]
● due to conductor-earth surge according to IEC 61000-4-52 kV (line to earth) corresponds to degree of severity 3
arrangement of electrical connectors for main current circuitTop and bottom
Number of auxiliary contacts as change-over contact (EF003531)0
● due to high-frequency radiation according to IEC 61000-4-610 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz
insulation voltage with degree of pollution 3 at AC rated value690 V
● due to conductor-conductor surge according to IEC 61000-4-51 kV (line to line) corresponds to degree of severity 3
Number of auxiliary contacts as normally open contact (EF001376)1
certificate of suitability according to ATEX directive 2014/34/EUPTB 09 ATEX 3001
● for short-circuit protection of the auxiliary switch requiredfuse gG: 6 A
Number of auxiliary contacts as normally closed contact (EF001377)1
Compliance with the substance restrictions according to RoHS directiveSince: 15.10.2014
product component removable terminal for auxiliary and control circuitYes
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
power loss [W] for rated value of the current at AC in hot operating state1.8 W
adjustable current response value current of the current-dependent overload release12.5 ... 50 A
maximum permissible voltage for safe isolation in networks with grounded star point
General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / ShippingSpecial Test CertificateType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top