| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209716162 |
| UPC | 662643527575 |
| ETIM | 4 |
| IDEA | 4 |
| Depth | 165 mm |
| Width | 90 mm |
| Height | 170 mm |
| UNSPSC | 14 |
| eClass | 6 |
| B10 value | |
| — solid | 2x (2.5 ... 6 mm²), 1x 10 mm² |
| Group Code | R711 |
| Trip class | CLASS 10 and 20 adjustable |
| Price Group | 42F |
| ● at AC-3 | |
| ● maximum | 2 000 m |
| Metal Factor | LCO----- |
| ● at 400 V | 53 kA |
| ● at AC-43 | |
| Holding power | |
| Mounting type | screw and snap-on mounting |
| Product Group | 5341 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Amount of data | |
| Commodity Code | 85364900 |
| Product family | 3RA65 reversing starters |
| last modified: | 08/13/2020 |
| number of LEDs | 5 |
| Display version | |
| Net Weight (kg) | 2,518 Kg |
| Operating power | |
| type of voltage | DC |
| Depth (EF000049) | 165.0 |
| Product function | |
| Shock resistance | a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes |
| Width (EF000008) | 90.0 |
| Country of origin | Germany |
| Height (EF000040) | 170.0 |
| Marine / Shipping | other |
| Operating current | |
| Operating voltage | |
| Product extension | |
| ● at DC maximum | 3.4 W |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| Type of assignment | continous operation according to IEC 60947-6-2 |
| product brand name | SIRIUS |
| ● during storage | -55 ... +80 °C |
| Ambient temperature | |
| Degree of pollution | 3 |
| Operating frequency | |
| Packaging Dimension | 183,00 x 228,00 x 109,50 |
| Product Description | SIRIUS Compact load feeder Reversing starter for IO-Link 400 V 24 V DC 8...32 A IP20 Connection main circuit: plug-in, without terminals Connection control circuit: screw terminal |
| Product designation | Compact starter for IO-Link |
| Vibration resistance | f= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles |
| With fuse (EF006693) | false |
| ● Auxiliary switch | Yes |
| ● IO-Link protocol | Yes |
| ● during operation | -20 ... +60 °C |
| ● during transport | -55 ... +80 °C |
| Design of the product | reversing starter |
| IO-Link transfer rate | COM2 (38,4 kBaud) |
| Number of CO contacts | |
| Number of NO contacts | |
| Protocol is supported | |
| ● for main contacts | |
| ● mounting position | any |
| Conducted interference | |
| Design of the fuse link | |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● Protection class IP | IP20 |
| General Product Approval | EMC |
| Product type designation | 3RA65 |
| Release class (EF006668) | Adjustable |
| — at 400 V rated value | 29 A |
| ● at 400 V rated value | 15 kW |
| ● at 480 V rated value | 32 A |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : N |
| ● for auxiliary contacts | |
| No-load switching frequency | 3 600 1/h |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| Package size unit of measure | MM |
| — at 200/208 V rated value | 7.5 hp |
| — at 220/230 V rated value | 10 hp |
| — at 460/480 V rated value | 20 hp |
| ● for three-phase AC motor | |
| Product Dimensions (W x L x H) | Not available |
| ● at AC at 400 V rated value | 32 A |
| ● at AC-3 rated value maximum | 400 V |
| Degree of protection NEMA rating | other |
| Proportion of dangerous failures | |
| Type of motor starter (EF009598) | Reversing starter |
| ● at AC in hot operating state | 5.4 W |
| ● of the main contacts typical | 10 000 000 |
| Rail mounting possible (EF003972) | - |
| ● Mounting position recommended | vertical, on horizontal standard mounting rail |
| ● of auxiliary contacts typical | 10 000 000 |
| Design of short-circuit protection | electromagnetic |
| External reset possible (EF003426) | - |
| Relative humidity during operation | 10 ... 90 % |
| product function bus communication | Yes |
| ● Insulation voltage rated value | 690 V |
| Yielded mechanical performance [hp] | |
| ● at DC-13 at 6 A at 24 V typical | 30 000 |
| Degree of protection (IP) (EF005474) | IP20 |
| Surge voltage resistance rated value | 6 000 V |
| ● at AC-15 at 6 A at 230 V typical | 200 000 |
| Article Number (Market Facing Number) | 3RA6500-1EB43 |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | 32 |
| Reference code acc. to DIN EN 81346-2 | Q |
| Voltage type for actuating (EF008242) | DC |
| With short-circuit release (EF006691) | true |
| ● of the signaling contacts typical | 10 000 000 |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | - |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● due to burst acc. to IEC 61000-4-4 | 4 kV main circuits, 2 kV auxiliary circuits, 2 kV IO-Link, 2 kV limit switches, 2 kV line hand-held device |
| ● at AWG conductors for main contacts | 2x (14 ... 10), 1x 8 |
| ● removable terminal for main circuit | Yes |
| Number of poles for main current circuit | 3 |
| Formula for making capacity limit current | 12 x Ie |
| Product function Short circuit protection | Yes |
| Supply voltage required Auxiliary voltage | Yes |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| ● at AC in hot operating state per pole | 1.8 W |
| Mechanical service life (switching cycles) | |
| Supporting protocol for SUCONET (EF003060) | - |
| ● at AC-41 acc. to IEC 60947-6-2 maximum | 750 1/h |
| ● at AC-43 acc. to IEC 60947-6-2 maximum | 250 1/h |
| ● with high demand rate acc. to SN 31920 | 1 500 000 |
| Mechanical power output for 4-pole AC motor | |
| Overload release current setting (EF002336) | ['8', '32'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| Number of NC contacts for auxiliary contacts | 0 |
| Number of NO contacts for auxiliary contacts | 0 |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| Type of connectable conductor cross-sections | |
| — finely stranded with core end processing | 2x (2.5 ... 6 mm²) |
| ● at AWG conductors for auxiliary contacts | 2x (20 ... 14) |
| Electrostatic discharge acc. to IEC 61000-4-2 | 8 kV |
| Power loss [W] for rated value of the current | |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| Formula for interruption capacity limit current | 10 x Ie |
| Installation altitude at height above sea level | |
| Rated operation power at AC-3, 400 V (EF001364) | 15.0 |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| Full-load current (FLA) for three-phase AC motor | |
| Rated control supply voltage Us at DC (EF003980) | ['-', '-'] |
| ● Control circuit interface to parallel wiring | No |
| Rated operation current at AC-3, 400 V (EF009602) | - |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| Conducted HF-interference emissions acc. to CISPR11 | 150 kHz ... 30 MHz Class A |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Type of voltage supply via input/output link master | No |
| Field-bound HF-interference emission acc. to CISPR11 | 30 ... 1000 MHz Class A |
| Field-bound parasitic coupling acc. to IEC 61000-4-3 | 80 ... 3000 MHz at 10V/m |
| Supporting protocol for other bus systems (EF003062) | - |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['-', '-'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['-', '-'] |
| ● as status display of the input/output link device | green/red dual LED |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| ● due to conductor-earth surge acc. to IEC 61000-4-5 | 4 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection |
| Product function Control circuit interface with IO link | Yes |
| Coordination class according to IEC 60947-4-3 (EF012390) | continous operation according to IEC 60947-6-2 |
| Operating current of auxiliary contacts at AC-12 maximum | 10 A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Other |
| ● removable terminal for auxiliary and control circuit | Yes |
| Operational short-circuit current breaking capacity (Ics) | |
| ● due to high-frequency radiation acc. to IEC 61000-4-6 | 0.15-80Mhz at 10V |
| ● Type of electrical connection for main current circuit | plug-in without terminals |
| ● due to conductor-conductor surge acc. to IEC 61000-4-5 | 2 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection |
| Electrical endurance (switching cycles) of auxiliary contacts | |
| ● operating current of auxiliary contacts at DC-13 at 250 V | 0.27 A |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| ● for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| ● of instantaneous short-circuit trip unit for signaling contact | 0 |
| ● of the address area of the inputs with cyclical transfer total | 2 byte |
| Point-to-point cycle time between master and IO-Link device minimum | 2.5 ms |
| ● of the address area of the outputs with cyclical transfer total | 2 byte |
| ● of the current-dependent overload release for signaling contact | 0 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| adjustable pick-up value current of the current-dependent overload release | 8 ... 32 A |
| ● Type of electrical connection for auxiliary and control current circuit | screw-type terminals |
| Power loss [W] for rated value of the current without load current share typical | 3.4 W |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Screw connection |
| General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide