Key Specifications
:Value
EAN:4011209716070
UPC:754554971223
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209716070
UPC754554971223
ETIM4
IDEA4
Depth165 mm
Width90 mm
Height170 mm
UNSPSC14
eClass6
B10 value
— solid2x (1.5 ... 6 mm²), 1x 10 mm²
Group CodeR711
Trip classCLASS 10 and 20 adjustable
Price Group42F
● at AC-3
● maximum2 000 m
Metal FactorLCO-----
● at 400 V53 kA
● at AC-43
Holding power
Mounting typescrew and snap-on mounting
Product Group5341
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Amount of data
Commodity Code85364900
Product family3RA65 reversing starters
last modified:08/13/2020
number of LEDs5
Display version
Net Weight (kg)2,552 Kg
Operating power
type of voltageDC
Depth (EF000049)165.0
Product function
Shock resistancea=60 m/s2 (6g) with 10 ms per 3 shocks in all axes
Width (EF000008)90.0
Country of originGermany
Height (EF000040)170.0
Marine / Shippingother
Operating current
Operating voltage
Product extension
● at DC maximum2.9 W
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
Type of assignmentcontinous operation according to IEC 60947-6-2
product brand nameSIRIUS
● during storage-55 ... +80 °C
Ambient temperature
Degree of pollution3
Operating frequency
Packaging Dimension183,00 x 228,00 x 109,50
Product DescriptionSIRIUS Compact load feeder Reversing starter for IO-Link 690 V 24 V DC 1...4 A IP20 Connection main circuit: Screw terminal Connection control circuit: screw terminal
Product designationCompact starter for IO-Link
Vibration resistancef= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles
With fuse (EF006693)false
● Auxiliary switchYes
● IO-Link protocolYes
● during operation-20 ... +60 °C
● during transport-55 ... +80 °C
Design of the productreversing starter
IO-Link transfer rateCOM2 (38,4 kBaud)
Number of CO contacts
Number of NO contacts
Protocol is supported
● for main contacts
● mounting positionany
Conducted interference
Design of the fuse link
Product Lifecycle (PLM)PM300:Active Product
● Protection class IPIP20
General Product ApprovalEMC
Product type designation3RA65
Release class (EF006668)Adjustable
— at 400 V rated value3.6 A
— at 500 V rated value3.9 A
— at 690 V rated value3.8 A
● at 400 V rated value1.5 kW
● at 480 V rated value4 A
● at 500 V rated value2.2 kW
● at 600 V rated value4 A
● at 690 V rated value3 kW
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : N
● for auxiliary contacts
No-load switching frequency3 600 1/h
Standard lead time ex-works2 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
Package size unit of measureMM
— at 200/208 V rated value0.75 hp
— at 220/230 V rated value0.75 hp
— at 460/480 V rated value2 hp
— at 575/600 V rated value3 hp
● for three-phase AC motor
Product Dimensions (W x L x H)Not available
● at AC at 400 V rated value4 A
● at AC-3 rated value maximum690 V
Degree of protection NEMA ratingother
Proportion of dangerous failures
Type of motor starter (EF009598)Reversing starter
● at AC in hot operating state1 W
● of the main contacts typical10 000 000
Rail mounting possible (EF003972)-
● Mounting position recommendedvertical, on horizontal standard mounting rail
● of auxiliary contacts typical10 000 000
Design of short-circuit protectionelectromagnetic
External reset possible (EF003426)-
Relative humidity during operation10 ... 90 %
product function bus communicationYes
● Insulation voltage rated value690 V
Yielded mechanical performance [hp]
● at DC-13 at 6 A at 24 V typical30 000
Degree of protection (IP) (EF005474)IP20
Surge voltage resistance rated value6 000 V
● at AC-15 at 6 A at 230 V typical200 000
Article Number (Market Facing Number)3RA6500-1CB42
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)4
Reference code acc. to DIN EN 81346-2Q
Voltage type for actuating (EF008242)DC
With short-circuit release (EF006691)true
● of the signaling contacts typical10 000 000
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● due to burst acc. to IEC 61000-4-44 kV main circuits, 2 kV auxiliary circuits, 2 kV IO-Link, 2 kV limit switches, 2 kV line hand-held device
● at AWG conductors for main contacts2x (16 ... 10), 1x 8
● removable terminal for main circuitYes
Number of poles for main current circuit3
Formula for making capacity limit current12 x Ie
Product function Short circuit protectionYes
Supply voltage required Auxiliary voltageYes
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
● at AC in hot operating state per pole0.33 W
Mechanical service life (switching cycles)
Supporting protocol for SUCONET (EF003060)-
● at AC-41 acc. to IEC 60947-6-2 maximum750 1/h
● at AC-43 acc. to IEC 60947-6-2 maximum250 1/h
● with high demand rate acc. to SN 319201 500 000
Mechanical power output for 4-pole AC motor
Overload release current setting (EF002336)['1', '4']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
Number of NC contacts for auxiliary contacts0
Number of NO contacts for auxiliary contacts0
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (1.5 ... 6 mm²)
● at AWG conductors for auxiliary contacts2x (20 ... 14)
Electrostatic discharge acc. to IEC 61000-4-28 kV
Power loss [W] for rated value of the current
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Formula for interruption capacity limit current10 x Ie
Installation altitude at height above sea level
Rated operation power at AC-3, 400 V (EF001364)1.5
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
Full-load current (FLA) for three-phase AC motor
Rated control supply voltage Us at DC (EF003980)['-', '-']
● Control circuit interface to parallel wiringNo
Rated operation current at AC-3, 400 V (EF009602)-
Supporting protocol for INTERBUS-Safety (EF006662)-
Conducted HF-interference emissions acc. to CISPR11150 kHz ... 30 MHz Class A
Supporting protocol for DeviceNet Safety (EF007520)-
Type of voltage supply via input/output link masterNo
Field-bound HF-interference emission acc. to CISPR1130 ... 1000 MHz Class A
Field-bound parasitic coupling acc. to IEC 61000-4-380 ... 3000 MHz at 10V/m
Supporting protocol for other bus systems (EF003062)-
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
● as status display of the input/output link devicegreen/red dual LED
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
● due to conductor-earth surge acc. to IEC 61000-4-54 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection
Product function Control circuit interface with IO linkYes
Coordination class according to IEC 60947-4-3 (EF012390)continous operation according to IEC 60947-6-2
Operating current of auxiliary contacts at AC-12 maximum10 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Screw connection
● removable terminal for auxiliary and control circuitYes
Operational short-circuit current breaking capacity (Ics)
● due to high-frequency radiation acc. to IEC 61000-4-60.15-80Mhz at 10V
● Type of electrical connection for main current circuitscrew-type terminals
● due to conductor-conductor surge acc. to IEC 61000-4-52 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection
Electrical endurance (switching cycles) of auxiliary contacts
● operating current of auxiliary contacts at DC-13 at 250 V0.27 A
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)0
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
● for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Number of auxiliary contacts as normally closed contact (EF001377)0
● of instantaneous short-circuit trip unit for signaling contact0
● of the address area of the inputs with cyclical transfer total2 byte
Point-to-point cycle time between master and IO-Link device minimum2.5 ms
● of the address area of the outputs with cyclical transfer total2 byte
● of the current-dependent overload release for signaling contact0
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable pick-up value current of the current-dependent overload release1 ... 4 A
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
Power loss [W] for rated value of the current without load current share typical2.9 W
Type of electrical connection for auxiliary- and control current circuit (EF006979)Screw connection
General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top