Key Specifications
:Value
EAN:4011209714939
UPC:662643527483
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209714939
UPC662643527483
ETIM4
IDEA4
depth165 mm
width45 mm
UNSPSC14
eClass6
height191 mm
B10 value
Group CodeR711
trip classCLASS 10 and 20 adjustable
Price Group42F
Metal FactorLCO-----
● at 250 V0.27 A
Holding power
Product Group5341
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Amount of data
Commodity Code85364900
Product family3RA64 direct-on-line starters
last modified:08/25/2020
number of LEDs3
Display version
Net Weight (kg)1,393 Kg
type of voltageDC
● rated value690 V
Depth (EF000049)165.0
Width (EF000008)45.0
Country of originGermany
Height (EF000040)191.0
Marine / Shippingother
● at DC maximum3.4 W
● mounting typescrew and snap-on mounting
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
Type of assignmentcontinous operation according to IEC 60947-6-2
insulation voltage
product brand nameSIRIUS
Operating frequency
Packaging Dimension181,50 x 228,50 x 59,50
Product DescriptionSIRIUS Compact load feeder DOL starter for IO-Link 690 V 24 V DC 8...32 A IP20 Connection main circuit: plug-in, without terminals Connection control circuit: Spring-type terminal
degree of pollution3
product designationCompact starter for IO-Link
protection class IPIP20
With fuse (EF006693)false
● shock resistancea=60 m/s2 (6g) with 10 ms per 3 shocks in all axes
IO-Link transfer rateCOM2 (38,4 kBaud)
design of the productdirect starter
● mounting positionany
Product Lifecycle (PLM)PM300:Active Product
General Product ApprovalEMC
Release class (EF006668)Adjustable
product type designation3RA64
— at 400 V rated value29 A
— at 500 V rated value17.6 A
— at 690 V rated value12.8 A
● at 400 V rated value15 kW
● at 480 V rated value32 A
● at 500 V rated value11 kW
● at 690 V rated value11 kW
● vibration resistancef= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles
Declaration of ConformityTest Certificates
Export Control RegulationsAL : N / ECCN : EAR99
No-load switching frequency3 600 1/h
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
● operating power at AC-3
Package size unit of measureMM
— at 200/208 V rated value7.5 hp
— at 220/230 V rated value10 hp
— at 460/480 V rated value20 hp
● Operating power at AC-43
● for main current circuitplug-in without terminals
● for three-phase AC motor
type of electrical connection
Product Dimensions (W x L x H)Not available
● Operating current at AC-43
Type of motor starter (EF009598)Direct online starter (DOL)
degree of protection NEMA ratingother
proportion of dangerous failures
Rail mounting possible (EF003972)-
● Mounting position recommendedvertical, on horizontal standard mounting rail
External reset possible (EF003426)-
product function bus communicationYes
relative humidity during operation10 ... 90 %
yielded mechanical performance [hp]
● at DC-13 at 6 A at 24 V typical30 000
Degree of protection (IP) (EF005474)IP20
surge voltage resistance rated value6 000 V
● at AC-15 at 6 A at 230 V typical200 000
Article Number (Market Facing Number)3RA6400-2EB43
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)32
Voltage type for actuating (EF008242)DC
With short-circuit release (EF006691)true
reference code acc. to DIN EN 81346-2Q
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● ambient temperature during storage-55 ... +80 °C
● design of short-circuit protectionelectromagnetic
● product extension auxiliary switchYes
number of poles for main current circuit3
● ambient temperature during operation-20 ... +60 °C
● ambient temperature during transport-55 ... +80 °C
Formula for making capacity limit current12 x Ie
Supply voltage required Auxiliary voltageYes
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
product function short circuit protectionYes
Supporting protocol for SUCONET (EF003060)-
● Protocol is supported IO-Link protocolYes
● at AC-41 acc. to IEC 60947-6-2 maximum750 1/h
● at AC-43 acc. to IEC 60947-6-2 maximum250 1/h
● with high demand rate acc. to SN 319202 000 000
Mechanical power output for 4-pole AC motor
Overload release current setting (EF002336)['8', '32']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
electrostatic discharge acc. to IEC 61000-4-28 kV
● for auxiliary and control current circuitspring-loaded terminals
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
Formula for interruption capacity limit current10 x Ie
Rated operation power at AC-3, 400 V (EF001364)15.0
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
Rated control supply voltage Us at DC (EF003980)['-', '-']
full-load current (FLA) for three-phase AC motor
operating current of auxiliary contacts at DC-13
● Operating current at AC at 400 V rated value32 A
● number of NC contacts for auxiliary contacts0
● number of NO contacts for auxiliary contacts0
Rated operation current at AC-3, 400 V (EF009602)-
● operating voltage at AC-3 rated value maximum400 V
Supporting protocol for INTERBUS-Safety (EF006662)-
Conducted HF-interference emissions acc. to CISPR11150 kHz ... 30 MHz Class A
Supporting protocol for DeviceNet Safety (EF007520)-
Type of voltage supply via input/output link masterNo
Field-bound HF-interference emission acc. to CISPR1130 ... 1000 MHz Class A
Supporting protocol for other bus systems (EF003062)-
field-bound parasitic coupling acc. to IEC 61000-4-380 ... 3000 MHz at 10V/m
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)['-', '-']
Rated control supply voltage Us at AC 60HZ (EF003979)['-', '-']
● as status display of the input/output link devicegreen/red dual LED
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
Product function Control circuit interface with IO linkYes
Coordination class according to IEC 60947-4-3 (EF012390)continous operation according to IEC 60947-6-2
Operating current of auxiliary contacts at AC-12 maximum10 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Other
● Product function removable terminal for main circuitYes
● installation altitude at height above sea level maximum2 000 m
Electrical endurance (switching cycles) of auxiliary contacts
● conducted interference due to burst acc. to IEC 61000-4-44 kV main circuits, 2 kV auxiliary circuits, 2 kV IO-Link, 2 kV limit switches, 2 kV line hand-held device
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)0
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
● Product function Control circuit interface to parallel wiringNo
Number of auxiliary contacts as normally closed contact (EF001377)0
● of the address area of the inputs with cyclical transfer total2 byte
Point-to-point cycle time between master and IO-Link device minimum2.5 ms
● of the address area of the outputs with cyclical transfer total2 byte
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
● Operational short-circuit current breaking capacity (Ics) at 400 V53 kA
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
● type of connectable conductor cross-sections for main contacts solid2x (2.5 ... 6 mm²), 1x 10 mm²
● product function removable terminal for auxiliary and control circuitYes
adjustable pick-up value current of the current-dependent overload release8 ... 32 A
● mechanical service life (switching cycles) of the main contacts typical10 000 000
● mechanical service life (switching cycles) of auxiliary contacts typical10 000 000
● Conducted interference due to conductor-earth surge acc. to IEC 61000-4-54 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection
● type of connectable conductor cross-sections for auxiliary contacts solid2x (0.25 ... 1.5 mm²)
● power loss [W] for rated value of the current at AC in hot operating state5.4 W
power loss [W] for rated value of the current without load current share typical3.4 W
● Mechanical service life (switching cycles) of the signaling contacts typical10 000 000
● conducted interference due to high-frequency radiation acc. to IEC 61000-4-60.15-80Mhz at 10V
● Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-52 kV main circuits, 0.5 kV auxiliary voltage with upstream overvoltage protection
● operational short-circuit current breaking capacity (Ics) at 500 V rated value1 kA
● operational short-circuit current breaking capacity (Ics) at 690 V rated value1 kA
Type of electrical connection for auxiliary- and control current circuit (EF006979)Spring clamp connection
● type of connectable conductor cross-sections at AWG conductors for main contacts2x (14 ... 10), 1x 8
● power loss [W] for rated value of the current at AC in hot operating state per pole1.8 W
● Number of NO contacts of instantaneous short-circuit trip unit for signaling contact0
● Number of CO contacts of the current-dependent overload release for signaling contact0
● design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
● type of connectable conductor cross-sections at AWG conductors for auxiliary contacts2x (24 ... 16)
● type of connectable conductor cross-sections for main contacts finely stranded with core end processing2x (2.5 ... 6 mm²)
● type of connectable conductor cross-sections for main contacts finely stranded without core end processing2x (2.5 ... 6 mm²)
● type of connectable conductor cross-sections for auxiliary contacts finely stranded with core end processing2x (0.25 ... 1.5 mm²)
● type of connectable conductor cross-sections for auxiliary contacts finely stranded without core end processing2x (0.25 ... 1.5 mm²)
General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top