| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209715332 |
| UPC | 662643360301 |
| ETIM | 4 |
| IDEA | 4 |
| depth | 165 mm |
| width | 90 mm |
| UNSPSC | 14 |
| eClass | 6 |
| height | 191 mm |
| B10 value | |
| ● at DC | 110 ... 240 V |
| Group Code | R711 |
| trip class | CLASS 10 and 20 adjustable |
| Price Group | 42F |
| Metal Factor | LCO----- |
| ● at 250 V | 0.27 A |
| ● at 50 Hz | 110 ... 240 V |
| ● at 60 Hz | 110 ... 240 V |
| Holding power | |
| Product Group | 5341 |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Quantity Unit | 1 Piece |
| Commodity Code | 85364900 |
| Product family | 3RA62 reversing starters |
| last modified: | 08/25/2020 |
| number of LEDs | 3 |
| Net Weight (kg) | 2,554 Kg |
| type of voltage | AC/DC |
| ● rated value | 690 V |
| Depth (EF000049) | 165.0 |
| Width (EF000008) | 90.0 |
| Country of origin | Germany |
| Height (EF000040) | 191.0 |
| Marine / Shipping | other |
| ● 1 rated value | 50 Hz |
| ● 2 rated value | 60 Hz |
| ● at AC maximum | 6 W |
| ● at DC maximum | 5.1 W |
| ● mounting type | screw and snap-on mounting |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Packaging Quantity | 1 |
| Type of assignment | continous operation according to IEC 60947-6-2 |
| failure rate [FIT] | |
| insulation voltage | |
| product brand name | SIRIUS |
| Operating frequency | |
| Packaging Dimension | 183,00 x 228,00 x 109,50 |
| Product Description | SIRIUS Compact load feeder Reversing starter 690 V 110...240 V AC/DC 50...60 Hz 0.32...1.25 A IP20 Connection main circuit: Spring-type terminal Connection control circuit: Spring-type terminal |
| degree of pollution | 3 |
| product designation | compact starter |
| protection class IP | IP20 |
| With fuse (EF006693) | false |
| ● shock resistance | a=60 m/s2 (6g) with 10 ms per 3 shocks in all axes |
| design of the product | reversing starter |
| ● mounting position | any |
| Product Lifecycle (PLM) | PM300:Active Product |
| Control supply voltage 1 | |
| General Product Approval | EMC |
| Release class (EF006668) | Adjustable |
| product type designation | 3RA62 |
| — at 400 V rated value | 1.1 A |
| — at 500 V rated value | 1.2 A |
| — at 690 V rated value | 1.1 A |
| ● at 400 V rated value | 0.37 kW |
| ● at 480 V rated value | 1.25 A |
| ● at 500 V rated value | 0.55 kW |
| ● at 600 V rated value | 1.25 A |
| ● at 690 V rated value | 0.75 kW |
| ● vibration resistance | f= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles |
| Declaration of Conformity | Test Certificates |
| Export Control Regulations | AL : N / ECCN : N |
| No-load switching frequency | 3 600 1/h |
| Standard lead time ex-works | 10 Day/Days |
| Surcharge for Raw Materials | None |
| With transformer (EF000278) | false |
| ● operating power at AC-3 | |
| Package size unit of measure | MM |
| — at 460/480 V rated value | 0.5 hp |
| — at 575/600 V rated value | 0.5 hp |
| ● Operating power at AC-43 | |
| ● for main current circuit | spring-loaded terminals |
| ● for three-phase AC motor | |
| type of electrical connection | |
| Control supply voltage 1 at AC | |
| Product Dimensions (W x L x H) | Not available |
| ● Operating current at AC-43 | |
| Type of motor starter (EF009598) | Reversing starter |
| control supply voltage frequency | |
| degree of protection NEMA rating | other |
| proportion of dangerous failures | |
| Rail mounting possible (EF003972) | - |
| ● Mounting position recommended | vertical, on horizontal standard mounting rail |
| External reset possible (EF003426) | - |
| product function bus communication | No |
| relative humidity during operation | 10 ... 90 % |
| yielded mechanical performance [hp] | |
| ● at DC-13 at 6 A at 24 V typical | 30 000 |
| Degree of protection (IP) (EF005474) | IP20 |
| surge voltage resistance rated value | 6 000 V |
| ● at AC-15 at 6 A at 230 V typical | 200 000 |
| Article Number (Market Facing Number) | 3RA6250-2BP32 |
| Number of indicator lights (EF001965) | - |
| Rated operation current Ie (EF001443) | 1.25 |
| Voltage type for actuating (EF008242) | AC/DC |
| With short-circuit release (EF006691) | true |
| reference code acc. to DIN EN 81346-2 | Q |
| Degree of protection (NEMA) (EF011959) | - |
| Number of command positions (EF001372) | - |
| Suitable for emergency stop (EF001433) | - |
| Supporting protocol for ASI (EF003051) | - |
| Supporting protocol for CAN (EF003053) | - |
| Supporting protocol for LON (EF003017) | - |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| ● ambient temperature during storage | -55 ... +80 °C |
| ● between main and auxiliary circuit | 400 V |
| ● design of short-circuit protection | electromagnetic |
| ● product extension auxiliary switch | Yes |
| number of poles for main current circuit | 3 |
| ● ambient temperature during operation | -20 ... +60 °C |
| ● ambient temperature during transport | -55 ... +80 °C |
| Formula for making capacity limit current | 38.4 x Ie |
| Supply voltage required Auxiliary voltage | No |
| Supporting protocol for Modbus (EF003057) | - |
| Supporting protocol for SERCOS (EF006657) | - |
| Supporting protocol for TCP/IP (EF003050) | - |
| product function short circuit protection | Yes |
| ● between control and auxiliary circuit | 300 V |
| ● with low demand rate acc. to SN 31920 | 40 % |
| Supporting protocol for SUCONET (EF003060) | - |
| ● Protocol is supported IO-Link protocol | No |
| ● at AC-41 acc. to IEC 60947-6-2 maximum | 750 1/h |
| ● at AC-43 acc. to IEC 60947-6-2 maximum | 250 1/h |
| ● with high demand rate acc. to SN 31920 | 3 000 000 |
| Mechanical power output for 4-pole AC motor | |
| Overload release current setting (EF002336) | ['0.32', '1.25'] |
| Supporting protocol for INTERBUS (EF003054) | - |
| Supporting protocol for PROFIBUS (EF003052) | - |
| ● between auxiliary and auxiliary circuit | 250 V |
| Supporting protocol for DeviceNet (EF003059) | - |
| Supporting protocol for PROFIsafe (EF007526) | - |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - |
| electrostatic discharge acc. to IEC 61000-4-2 | 8 kV |
| ● for auxiliary and control current circuit | spring-loaded terminals |
| Supporting protocol for EtherNet/IP (EF007521) | - |
| Supporting protocol for PROFINET IO (EF007525) | - |
| Supporting protocol for SafetyBUS p (EF007527) | - |
| maximum permissible voltage for safe isolation | |
| Formula for interruption capacity limit current | 32 x Ie |
| Rated operation power at AC-3, 400 V (EF001364) | 0.37 |
| Supporting protocol for Data-Highway (EF003058) | - |
| Supporting protocol for PROFINET CBA (EF007524) | - |
| ● protocol is supported AS-Interface protocol | No |
| Rated control supply voltage Us at DC (EF003980) | ['110', '240'] |
| full-load current (FLA) for three-phase AC motor | |
| operating current of auxiliary contacts at DC-13 | |
| ● Operating current at AC at 400 V rated value | 1.25 A |
| ● number of NC contacts for auxiliary contacts | 0 |
| ● number of NO contacts for auxiliary contacts | 2 |
| Rated operation current at AC-3, 400 V (EF009602) | - |
| ● operating voltage at AC-3 rated value maximum | 690 V |
| Supporting protocol for INTERBUS-Safety (EF006662) | - |
| Conducted HF-interference emissions acc. to CISPR11 | 150 kHz ... 30 MHz Class A |
| Supporting protocol for DeviceNet Safety (EF007520) | - |
| Field-bound HF-interference emission acc. to CISPR11 | 30 ... 1000 MHz Class A |
| Supporting protocol for other bus systems (EF003062) | - |
| contact rating of auxiliary contacts according to UL | contacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300 |
| field-bound parasitic coupling acc. to IEC 61000-4-3 | 10 V/m |
| Ambient temperature, upper operating limit (EF009603) | - |
| Rated control supply voltage Us at AC 50HZ (EF003978) | ['110', '240'] |
| Rated control supply voltage Us at AC 60HZ (EF003979) | ['110', '240'] |
| Supporting protocol for Foundation Fieldbus (EF007522) | - |
| Temperature compensated overload protection (EF009604) | - |
| Product function Control circuit interface with IO link | No |
| Coordination class according to IEC 60947-4-3 (EF012390) | continous operation according to IEC 60947-6-2 |
| Operating current of auxiliary contacts at AC-12 maximum | 10 A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - |
| Type of electrical connection of main circuit (EF006819) | Spring clamp connection |
| ● Product function removable terminal for main circuit | Yes |
| ● installation altitude at height above sea level maximum | 2 000 m |
| Electrical endurance (switching cycles) of auxiliary contacts | |
| ● conducted interference due to burst acc. to IEC 61000-4-4 | 4 kV main contacts, 2 kV auxiliary contacts |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - |
| Number of auxiliary contacts as normally open contact (EF001376) | 2 |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - |
| ● Product function Control circuit interface to parallel wiring | Yes |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| T1 value for proof test interval or service life acc. to IEC 61508 | 20 y |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.05.2012 |
| ● Operational short-circuit current breaking capacity (Ics) at 400 V | 53 kA |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| ● type of connectable conductor cross-sections for main contacts solid | 2x (1.5 ... 6 mm²), 1x 10 mm² |
| ● product function removable terminal for auxiliary and control circuit | Yes |
| adjustable pick-up value current of the current-dependent overload release | 0.32 ... 1.25 A |
| ● mechanical service life (switching cycles) of the main contacts typical | 10 000 000 |
| ● mechanical service life (switching cycles) of auxiliary contacts typical | 10 000 000 |
| ● Conducted interference due to conductor-earth surge acc. to IEC 61000-4-5 | 4 kV main contacts, 2 kV auxiliary contacts |
| ● type of connectable conductor cross-sections for auxiliary contacts solid | 2x (0.25 ... 1.5 mm²) |
| ● power loss [W] for rated value of the current at AC in hot operating state | 0.1 W |
| power loss [W] for rated value of the current without load current share typical | 6 W |
| ● Mechanical service life (switching cycles) of the signaling contacts typical | 10 000 000 |
| ● conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | 0.15-80Mhz at 10V |
| ● Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-5 | 2 kV main contacts, 1 kV auxiliary contacts |
| ● operational short-circuit current breaking capacity (Ics) at 500 V rated value | 3 kA |
| ● operational short-circuit current breaking capacity (Ics) at 690 V rated value | 3 kA |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Spring clamp connection |
| ● type of connectable conductor cross-sections at AWG conductors for main contacts | 2x (16 ... 10), 1x 8 |
| ● power loss [W] for rated value of the current at AC in hot operating state per pole | 0.03 W |
| ● Number of NO contacts of instantaneous short-circuit trip unit for signaling contact | 1 |
| ● Number of CO contacts of the current-dependent overload release for signaling contact | 1 |
| ● design of the fuse link for short-circuit protection of the auxiliary switch required | fuse gL/gG: 10 A |
| ● type of connectable conductor cross-sections at AWG conductors for auxiliary contacts | 2x (24 ... 16) |
| ● type of connectable conductor cross-sections for main contacts finely stranded with core end processing | 2x (1.5 ... 6 mm²) |
| ● type of connectable conductor cross-sections for main contacts finely stranded without core end processing | 2x (1.5 ... 6 mm²) |
| ● type of connectable conductor cross-sections for auxiliary contacts finely stranded with core end processing | 2x (0.25 ... 1.5 mm²) |
| ● Design of the fuse link for short-circuit protection of the signaling switch of the overload release required | 4A gL/gG/400V |
| ● type of connectable conductor cross-sections for auxiliary contacts finely stranded without core end processing | 2x (0.25 ... 1.5 mm²) |
| ● Design of the fuse link for short-circuit protection of the signaling switch of the short-circuit release required | 6A gL/gG/400V |
| General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmation | General Product Approval |
Technical specifications and performance data
Installation and operation guide