Service time: Monday to Friday 9:00-18:00
3RA6120-1EP33 - 3RA6120-1EP33 SIEMENS SIRIUS Compact load feeder DOL starter 690 V 110...240 V AC/DC 50...60 Hz 8...32 A IP2..
In Stock Hot Product

3RA6120-1EP33

3RA6120-1EP33 SIEMENS SIRIUS Compact load feeder DOL starter 690 V 110...240 V AC/DC 50...60 Hz 8...32 A IP2..

$0.00USD
4773 in stock
Key Specifications
:Value
EAN:4011209714717
UPC:662643359091
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209714717
UPC662643359091
ETIM4
IDEA4
Depth165 mm
Width45 mm
Height170 mm
UNSPSC14
eClass6
B10 value
— solid2x (2.5 ... 6 mm²), 1x 10 mm²
● at DC110 ... 240 V
Group CodeR711
Trip classCLASS 10 and 20 adjustable
Price Group42F
● at AC-3
● maximum2 000 m
Metal FactorLCO-----
● at 400 V53 kA
● at 50 Hz110 ... 240 V
● at 60 Hz110 ... 240 V
● at AC-43
Holding power
Mounting typescrew and snap-on mounting
Product Group5341
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
Quantity Unit1 Piece
Commodity Code85364900
Product family3RA61 direct-on-line starters
last modified:08/13/2020
number of LEDs2
Net Weight (kg)1,440 Kg
Operating power
type of voltageAC/DC
Depth (EF000049)165.0
Product function
Shock resistancea=60 m/s2 (6g) with 10 ms per 3 shocks in all axes
Width (EF000008)45.0
Country of originGermany
Height (EF000040)170.0
Marine / Shippingother
Operating current
Operating voltage
Product extension
● 1 rated value50 Hz
● 2 rated value60 Hz
● at AC maximum5.2 W
● at DC maximum5.8 W
Failure rate [FIT]
LKZ_FDB/ CatalogIDCC-IC10
Packaging Quantity1
Type of assignmentcontinous operation according to IEC 60947-6-2
product brand nameSIRIUS
● during storage-55 ... +80 °C
Ambient temperature
Degree of pollution3
Operating frequency
Packaging Dimension181,50 x 228,50 x 59,50
Product DescriptionSIRIUS Compact load feeder DOL starter 690 V 110...240 V AC/DC 50...60 Hz 8...32 A IP20 Connection main circuit: plug-in, without terminals Connection auxiliary circuit: screw terminal
Product designationcompact starter
Vibration resistancef= 4 ... 5.8 Hz, d= 15 mm; f= 5.8 ... 500 Hz, a= 20 m/s²; 10 cycles
With fuse (EF006693)false
● Auxiliary switchYes
● IO-Link protocolNo
● during operation-20 ... +60 °C
● during transport-55 ... +80 °C
Design of the productdirect starter
Number of CO contacts
Number of NO contacts
Protocol is supported
● for main contacts
● mounting positionany
Conducted interference
Design of the fuse link
Product Lifecycle (PLM)PM300:Active Product
● Protection class IPIP20
Control supply voltage 1
General Product ApprovalEMC
Product type designation3RA61
Release class (EF006668)Adjustable
— at 400 V rated value29 A
— at 500 V rated value17.6 A
— at 690 V rated value12.8 A
● at 400 V rated value15 kW
● at 480 V rated value32 A
● at 500 V rated value11 kW
● at 690 V rated value11 kW
Declaration of ConformityTest Certificates
● AS-Interface protocolNo
Export Control RegulationsAL : N / ECCN : N
● for auxiliary contacts
No-load switching frequency3 600 1/h
Standard lead time ex-works10 Day/Days
Surcharge for Raw MaterialsNone
With transformer (EF000278)false
Package size unit of measureMM
— at 200/208 V rated value7.5 hp
— at 220/230 V rated value10 hp
— at 460/480 V rated value20 hp
● for three-phase AC motor
Control supply voltage 1 at AC
Product Dimensions (W x L x H)Not available
● at AC at 400 V rated value32 A
● at AC-3 rated value maximum690 V
Degree of protection NEMA ratingother
Proportion of dangerous failures
Type of motor starter (EF009598)Direct online starter (DOL)
control supply voltage frequency
● at AC in hot operating state5.4 W
● of the main contacts typical10 000 000
Rail mounting possible (EF003972)-
● Mounting position recommendedvertical, on horizontal standard mounting rail
● of auxiliary contacts typical10 000 000
Design of short-circuit protectionelectromagnetic
External reset possible (EF003426)-
Relative humidity during operation10 ... 90 %
product function bus communicationNo
● Insulation voltage rated value690 V
Yielded mechanical performance [hp]
● at DC-13 at 6 A at 24 V typical30 000
Degree of protection (IP) (EF005474)IP20
Surge voltage resistance rated value6 000 V
● at AC-15 at 6 A at 230 V typical200 000
Article Number (Market Facing Number)3RA6120-1EP33
Number of indicator lights (EF001965)-
Rated operation current Ie (EF001443)32
Reference code acc. to DIN EN 81346-2Q
Voltage type for actuating (EF008242)AC/DC
With short-circuit release (EF006691)true
● of the signaling contacts typical10 000 000
Degree of protection (NEMA) (EF011959)-
Number of command positions (EF001372)-
Suitable for emergency stop (EF001433)-
Supporting protocol for ASI (EF003051)-
Supporting protocol for CAN (EF003053)-
Supporting protocol for LON (EF003017)-
WEEE (2012/19/EU) Take-Back ObligationYes
● between main and auxiliary circuit400 V
● due to burst acc. to IEC 61000-4-44 kV main contacts, 2 kV auxiliary contacts
● at AWG conductors for main contacts2x (14 ... 10), 1x 8
● removable terminal for main circuitYes
Number of poles for main current circuit3
Formula for making capacity limit current12 x Ie
Product function Short circuit protectionYes
Supply voltage required Auxiliary voltageNo
Supporting protocol for Modbus (EF003057)-
Supporting protocol for SERCOS (EF006657)-
Supporting protocol for TCP/IP (EF003050)-
● at AC in hot operating state per pole1.8 W
● between control and auxiliary circuit300 V
● with low demand rate acc. to SN 3192040 %
Mechanical service life (switching cycles)
Supporting protocol for SUCONET (EF003060)-
● at AC-41 acc. to IEC 60947-6-2 maximum750 1/h
● at AC-43 acc. to IEC 60947-6-2 maximum250 1/h
● with high demand rate acc. to SN 319202 000 000
Mechanical power output for 4-pole AC motor
Overload release current setting (EF002336)['8', '32']
Supporting protocol for INTERBUS (EF003054)-
Supporting protocol for PROFIBUS (EF003052)-
● between auxiliary and auxiliary circuit250 V
Number of NC contacts for auxiliary contacts1
Number of NO contacts for auxiliary contacts1
Supporting protocol for DeviceNet (EF003059)-
Supporting protocol for PROFIsafe (EF007526)-
Type of connectable conductor cross-sections
— finely stranded with core end processing2x (2.5 ... 6 mm²)
● at AWG conductors for auxiliary contacts2x (20 ... 14)
Electrostatic discharge acc. to IEC 61000-4-28 kV
Power loss [W] for rated value of the current
Rated power, 460 V, 60 Hz, 3-phase (EF009600)-
Rated power, 575 V, 60 Hz, 3-phase (EF009601)-
Supporting protocol for EtherNet/IP (EF007521)-
Supporting protocol for PROFINET IO (EF007525)-
Supporting protocol for SafetyBUS p (EF007527)-
maximum permissible voltage for safe isolation
Formula for interruption capacity limit current10 x Ie
Installation altitude at height above sea level
Rated operation power at AC-3, 400 V (EF001364)15.0
Supporting protocol for Data-Highway (EF003058)-
Supporting protocol for PROFINET CBA (EF007524)-
Full-load current (FLA) for three-phase AC motor
Rated control supply voltage Us at DC (EF003980)['110', '240']
● Control circuit interface to parallel wiringYes
Rated operation current at AC-3, 400 V (EF009602)-
Supporting protocol for INTERBUS-Safety (EF006662)-
Conducted HF-interference emissions acc. to CISPR11150 kHz ... 30 MHz Class A
Supporting protocol for DeviceNet Safety (EF007520)-
Contact rating of auxiliary contacts according to ULcontacts 21-22, 13-14, 43-44 Q600 / A600, contacts 77-78 R300 / B300, contacts 95-96-98 R300 / D300
Field-bound HF-interference emission acc. to CISPR1130 ... 1000 MHz Class A
Field-bound parasitic coupling acc. to IEC 61000-4-310 V/m
Supporting protocol for other bus systems (EF003062)-
Ambient temperature, upper operating limit (EF009603)-
Rated control supply voltage Us at AC 50HZ (EF003978)['110', '240']
Rated control supply voltage Us at AC 60HZ (EF003979)['110', '240']
Supporting protocol for Foundation Fieldbus (EF007522)-
Temperature compensated overload protection (EF009604)-
● due to conductor-earth surge acc. to IEC 61000-4-54 kV main contacts, 2 kV auxiliary contacts
Product function Control circuit interface with IO linkNo
Coordination class according to IEC 60947-4-3 (EF012390)continous operation according to IEC 60947-6-2
Operating current of auxiliary contacts at AC-12 maximum10 A
Rated operation power at AC-3, 230 V, 3-phase (EF009599)-
Type of electrical connection of main circuit (EF006819)Other
● removable terminal for auxiliary and control circuitYes
Operational short-circuit current breaking capacity (Ics)
● due to high-frequency radiation acc. to IEC 61000-4-60.15-80Mhz at 10V
● Type of electrical connection for main current circuitplug-in without terminals
● due to conductor-conductor surge acc. to IEC 61000-4-52 kV main contacts, 1 kV auxiliary contacts
Electrical endurance (switching cycles) of auxiliary contacts
● operating current of auxiliary contacts at DC-13 at 250 V0.27 A
Supporting protocol for AS-Interface Safety at Work (EF007519)-
Number of auxiliary contacts as normally open contact (EF001376)1
Rated conditional short-circuit current, type 2, 230 V (EF009606)-
Rated conditional short-circuit current, type 2, 400 V (EF009605)-
● for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Number of auxiliary contacts as normally closed contact (EF001377)1
T1 value for proof test interval or service life acc. to IEC 6150820 y
● of instantaneous short-circuit trip unit for signaling contact1
● of the current-dependent overload release for signaling contact1
Compliance with the substance restrictions according to RoHS directiveSince: 01.05.2012
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607)-
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608)-
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
adjustable pick-up value current of the current-dependent overload release8 ... 32 A
● Type of electrical connection for auxiliary and control current circuitscrew-type terminals
Power loss [W] for rated value of the current without load current share typical5.8 W
Type of electrical connection for auxiliary- and control current circuit (EF006979)Screw connection
● for short-circuit protection of the signaling switch of the overload release required4A gL/gG/400V
● for short-circuit protection of the signaling switch of the short-circuit release required6A gL/gG/400V
General Product ApprovalEMCFunctional Safety/Safety of MachineryDeclaration of ConformityTest CertificatesMarine / ShippingMiscellaneousType Test Certificates/Test ReportMarine / ShippingotherConfirmationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top